File name Denon-DRA37_297_397 rec.pdfFor U.S.A. & Canada model
Ver. 2
SERVICE MANUAL Please refer to the
MODIFICATION NOTICE.
MODEL DRA-397
DRA-297
DRA-37
AM-FM STEREO RECEIVER
For purposes of improvement, specifications and
design are subject to change without notice.
Please use this service manual with referring to the
operating instructions without fail.
Some illustrations using in this service manual are
slightly different from the actual set.
TOKYO, JAPAN
Denon Brand Company, D&M Holdings Inc.
X0282V.02 DE/CDM 0701
DRA-397/297/37
SAFETY PRECAUTIONS
The following check should be performed for the continued protection of the customer and service technician.
LEAKAGE CURRENT CHECK
Before returning the unit to the customer, make sure you make either (1) a leakage current check or (2) a line to chassis
resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power
cord is less than 460 kohms, the unit is defective.
CAUTION Please heed the points listed below during servicing and inspection.
Heed the cautions! Inspect for safety after servicing!
Spots requiring particular attention when servicing, such as Check that all screws, parts and wires removed or discon-
the cabinet, parts, chassis, etc., have cautions indicated on nected for servicing have been put back in their original posi-
labels or seals. Be sure to heed these cautions and the cau- tions, inspect that no parts around the area that has been
tions indicated in the handling instructions. serviced have been negatively affected, conduct an insulation
check on the external metal connectors and between the
Caution concerning electric shock! blades of the power plug, and otherwise check that safety is
ensured.
(1) An AC voltage is impressed on this set, so touching inter-
nal metal parts when the set is energized could cause
(Insulation check procedure)
electric shock |