File name As99-02.pdf For internal use only PHILIPS ISSUE AS99.02 (99-04-30) Published by: Service Department Audio Systems LINE OF BUSINESS AUDIO SYSTEMS SERVICE NEWSLETTER 02.01 TYPENUMBER(S): GENERAL SYMPTOM : IRIS CODE 3 1 3 X The clock runs too fast/slow, approximate 1-2 minutes per month. CURE : In addition to Newsletter issue AS98.09.02, the clock accuracy can also be corrected by replacing the 32.768kHz crystal by an improved one. The service codenumber for the improved crystal reads 2422 543 01069. REMARKS : 02.02 TYPENUMBERS : FW72C, FW346C, FW356C, FW358C, FW359C, FW388V, FW530C, FW535C, FW538, FW550C, FW570C, FW575C, FW765P, FW775P, FW795W, FW850C, FW855C, FW860P, FW880P, FW880W SYMPTOM : IRIS CODE 1 6 1 5 The cassette doors (especially the left door) do not close properly. CURE : In addition to Newsletter issue AS98.09.03, the improved brackets (left & right) can be recognized by the modification shown below: Bracket-left : 4822 402 11245 Bracket-right : 4822 402 11246 Service Newsletter 1999 |