Text preview for : As99-02.pdf part of Philips As99-02 Philips Symptom Cure 2001-02 SymptomCure references As99-02.pdf
Back to : As99-02.pdf | Home
For internal use only PHILIPS
ISSUE AS99.02 (99-04-30)
Published by:
Service Department Audio Systems
LINE OF BUSINESS AUDIO SYSTEMS
SERVICE NEWSLETTER
02.01 TYPENUMBER(S): GENERAL
SYMPTOM : IRIS CODE 3 1 3 X
The clock runs too fast/slow, approximate 1-2 minutes per month.
CURE : In addition to Newsletter issue AS98.09.02, the clock accuracy can
also be corrected by replacing the 32.768kHz crystal by an improved
one. The service codenumber for the improved crystal reads
2422 543 01069.
REMARKS :
02.02 TYPENUMBERS : FW72C, FW346C, FW356C, FW358C, FW359C, FW388V, FW530C,
FW535C, FW538, FW550C, FW570C, FW575C, FW765P, FW775P,
FW795W, FW850C, FW855C, FW860P, FW880P, FW880W
SYMPTOM : IRIS CODE 1 6 1 5
The cassette doors (especially the left door) do not close properly.
CURE : In addition to Newsletter issue AS98.09.03, the improved brackets
(left & right) can be recognized by the modification shown below:
Bracket-left : 4822 402 11245 Bracket-right : 4822 402 11246
Service Newsletter 1999