File information: | |
File name: | 08_adjustmentmethod.pdf [preview 08 adjustmentmethod] |
Size: | 13 kB |
Extension: | |
Mfg: | panasonic |
Model: | 08 adjustmentmethod 🔎 |
Original: | 08 adjustmentmethod 🔎 |
Descr: | panasonic LED TX-42AX500E PCZ1402033CE doc 08_adjustmentmethod.pdf |
Group: | Electronics > Documentation |
Uploaded: | 15-04-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 08_adjustmentmethod.pdf Adjustment Method White Balance Adjustment Instrument Name Connect to Remarks 1. Remote controller Correlation can be also taken by 2. LCD WB meter (Minolta CA-210 or equivalent) CS-1000A or equivalent 3. Comunication jig 4. Computer for external control Procedure Remarks Let the panel standfor more than 3 hours at more than 20 C. White Balance adjustment Basically perform adjustment in the 1. Procedure basically performs checking using the production software and ambient environment of room make automatic adjustment using external computer. temperature more than 20 C. 2. It adjusts in the mode of: Colour balance Normal The aging time is more than 20 min Viewing Mode Dynamic at above room temperature. Applied signal Normal 100% full colour bar Highlight x: 0.288 0.010 0.7V p-p white peak y: 0.297 0.010 85% modulation Normal Lowlight x: 0.288 0.010 100% WHITE y: 0.297 0.010 50% GRAY |