File name p06.pdf 6 107B2 CM24 GSIII OSD Lock Function & Service Mode 9 Go to cover page To lock (disable) OSD function: Access Factory Mode - Press OSD button " " for over 15 seconds to lock the OSD function. Firstly, get into Factory Adjustment Mode. Release it, then OSD comes on the screen as below. Push LEFT & RIGHT buttons at the same time for over 15 seconds and release them. ATTENTION The factory message appears at the bottom of the main OSD menu. (for example : GS3 107B2 V1.41 20000630; CONTROL MENU IS LOCKED 00115 is M.used hours) 00115 To unlock (enable) OSD function: - Press OSD button " " for over 15 seconds again to unlock the OSD function. Release it, then OSD comes on the screen as below. GS3 107B2 v1.41 20000630 Access Service Mode - Disconnect the Interface cable of the monitor. - Push LEFT & RIGHT buttons at the same time, then power ON. - If it is successful, the signal " " comes on the screen later. SERVICE MODE MODEL SELECT (Background is white.). SERIAL NO: TY 123456 HOURS : 00021 FACTORY VER 1.01 990706 Exit "Service Mode" : GS3 107B2 V1.41 20000630 - Apply a normal VGA Signal to monitor, then monitor will exit " service mode" back to normal. Disable/Enable all the W |