datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent HP 81110A Manual Changes p5

Agilent HP 81110A Manual Changes p5 free download

Various electronics service manuals

File information:
File name:HP 81110A Manual Changes p5.pdf
[preview HP 81110A Manual Changes p5]
Size:116 kB
Extension:pdf
Mfg:Agilent
Model:HP 81110A Manual Changes p5 🔎
Original:HP 81110A Manual Changes p5 🔎
Descr: Agilent HP 81110A Document Set HP 81110A Manual Changes p5.pdf
Group:Electronics > Other
Uploaded:25-08-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name HP 81110A Manual Changes p5.pdf

MANUAL CHANGES September, 01 Manual for Model Number 81110A,81104A Manual printed on April 2000 Edition1.1, E0400 Manual Part Number 81110-91021 Make all ERRATA corrections. Check the following table for your instrument serial prefix/serial number/EDC and make the listed changes to your manual New Item Serial Prefix or Manual Serial Prefix or Manual Serial Number Change Serial Number Change ERRATA 81104A 81110A DE387 00466 DE387 00805 Serialnumber independent 1 Serialnumber independent 1 5 September, 2001 Page 1 of 4 MODEL 81110A,81104A ____________________________________________________________________ Reference Quide: 81110A/81105A (P/N 81110-91021), page 106 Chapter: Agilent 81110A/81105A Specifications Width Accuracy 81111A: +/- 0.5% +/- 250ps(*) after selfcal, typical +/-3% +/-250ps(*) without selfcal 81105A: +/- 5% +/- 250ps(*) (*) Width accuracy specification is valid up to 5.5Vpp amplitude. Above 5.5Vpp, the width may increase typically up to +300ps . Page 103, Power consumption: 170VA max. Page 104, Specifications change to read: Recalibration period 3 years recommended Page 7, Output Modules for Agilent 81110A Mainframes add: The 81111A output modules are fitted with single ended outputs. Therefore the connectors for the complementary outputs have no functionality. Complementary outputs are only available when 81112A output modules are installed. (The 81110A always is fitted with connectors for the normal and the complementary outputs, regardless of the configuration. It has been designed this way to allow the easy retrofit of the output channels.) Page 106, Glitch-free timing changes change to read: This applies to continous mode with timing values < 100 ms (frequency: > 10 Hz), and consecutive values between one-half and twice the previous value. Page 106, Width add: The pulse width is specified at fastest transitions. Page 107, Delay add: Delay and Double Pulse Delay are specified at fastest leading edges. __________________________________________________________________________________ 05.09.01 Page 2 of 4 MODEL 81110A,81104A ____________________________________________________________________ INDEX OF MANUAL CHANGE MANUAL FRAME CHANGE ERRATA 1 See attached Declaration of Conformity ______________

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : PHILIPS HTS3357

script execution: 0.07 s