File information: | |
File name: | Y1225-90001 Y1225A Rack Mount Kit - Installation Note c20140923 [6].pdf [preview Y1225-90001 Y1225A Rack Mount Kit - Installation Note c20140923 [6]] |
Size: | 1204 kB |
Extension: | |
Mfg: | Agilent |
Model: | Y1225-90001 Y1225A Rack Mount Kit - Installation Note c20140923 [6] 🔎 |
Original: | Y1225-90001 Y1225A Rack Mount Kit - Installation Note c20140923 [6] 🔎 |
Descr: | Agilent Y1225-90001 Y1225A Rack Mount Kit - Installation Note c20140923 [6].pdf |
Group: | Electronics > Other |
Uploaded: | 25-08-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name Y1225-90001 Y1225A Rack Mount Kit - Installation Note c20140923 [6].pdf Keysight Y1225A Rack Mount Kit Installation This installation note contains procedures for installing the Y1225A Rack Mount Kit for the Keysight M9502A 2-slot AXIe Chassis in a standard EIA rack. Parts List The parts included with each rack mount adapter option and the support rail are shown in the following table: Quantity Description Part Number 1 Rack Flange Kit N5650-00020 4 Rack Flange Screws M4x6 Flat Head N/A 2 Support Rails M9018-00001 8 Channel Nuts (for support rail-to-rack) 0590-0804 4 Support Rail-to-Rack Screws - 10-32 x 0.5 2680-0278 4 Dress Adapter Screws for rack flanges E9900-06001 General Guidelines In rack mounting the chassis, follow these guidelines: 1 Always begin installing the chassis and heavy instruments at the bottom of the rack and work up. This maintains a lower center of gravity and reduces the possibility of the rack tipping. 2 Anti-tipping feet, if available with the rack, should always be extended. 3 The heaviest instrument of chassis should always be mounted at the bottom of the rack. 4 For maximum cooling and optimum rack thermal efficiency, place the instrument or chassis with the greatest power consumption towards the top of the rack. This promotes efficient cooling since heat rises when placed nearer to the top of the rack, high power instruments will not unnecessarily heat other instruments. However, in doing this, do not violate the guideline that the heaviest instruments should be placed at the bottom of the rack. 5 If instruments or modules in the chassis are consuming maximum power, 1U of rack space is required for ventilation below the chassis. Keysight Y1225A Rack Mount Kit Installation Procedure 1 The M9502A AXIe chassis has a single carry handle which must be removed before removing the bumpers. Remove the two #2 Phillips screws securing the handle.See Figure 1. Figure 1 . Removing the Carry Handle 2 Remove the four #2 Phillips screws from each side of both bumpers. See Figure 2. Figure 2 . Removing the Chassis Bumpers 3 Using the rack mount flanges as templates, position the flanges on the rack's |
Date | User | Rating | Comment |