File information: | |
File name: | 5990-4391EN E5061B Network Analyzer - Configuration Guide c20140725 [17].pdf [preview 5990-4391EN E5061B Network Analyzer - Configuration Guide c20140725 [17]] |
Size: | 683 kB |
Extension: | |
Mfg: | Agilent |
Model: | 5990-4391EN E5061B Network Analyzer - Configuration Guide c20140725 [17] 🔎 |
Original: | 5990-4391EN E5061B Network Analyzer - Configuration Guide c20140725 [17] 🔎 |
Descr: | Agilent 5990-4391EN E5061B Network Analyzer - Configuration Guide c20140725 [17].pdf |
Group: | Electronics > Other |
Uploaded: | 26-08-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 5990-4391EN E5061B Network Analyzer - Configuration Guide c20140725 [17].pdf Keysight E5061B Network Analyzer Coniguration Guide 02 | Keysight | E5061B Network Analyzer - Coniguration Guide Ordering guide The following steps will guide you through coniguring your E5061B. Standard furnished item 1 Description Additional information Installation guide Contains the information necessary to start up with the E5061B. CD ROM IO libraries Power cable Certiicate of calibration Step 1. Choose test set option (must choose one of the nine test set options.) Option No. Description 50 RF NA options E5061B-115 Transmission/Relection test set, 100 kHz to 1.5 GHz, 50 system impedance E5061B-215 S-parameter test set, 100 kHz to 1.5 GHz, 50 system impedance E5061B-135 Transmission/Relection test set, 100 kHz to 3 GHz, 50 system impedance E5061B-235 S-parameter test set, 100 kHz to 3GHz, 50 system impedance 75 RF NA options E5061B-117 Transmission/Relection test set, 100 kHz to 1.5 GHz, 75 system impedance E5061B-217 S-parameter test set, 100 kHz to 1.5 GHz, 75 system impedance E5061B-137 Transmission/Relection test set, 100 kHz to 3 GHz, 75 system impedance E5061B-237 S-parameter test set, 100 kHz to 3GHz, 75 system impedance LF-RF NA option E5061B-3L5 2 LF-RF network analyzer with DC bias source, 5 Hz to 3 GHz Step 2. Choose impedance analysis option (for E5061B-3L5 LF-RF network analyzer. If not required, go to step 3.) Option No. Description Software option E5061B-005 3, 4 Impedance analysis for E5061B-3L5 LF-RF network analyzer Accessory E5061B-720 4, 5 Add 50 resistor set 1. Keyboard and mouse are not furnished as standard. Refer to "Step 6. accessory option" for the selection of these items. 2. The E5061B-3L5 includes the 50 ohm S-parameter test set (5 Hz to 3 GHz), and the gain-phase test port (5 Hz to 30 MHz) 3. This option is not applicable for the E5061B RF NA options 1x5/2x5/1x7/2x7. 4. Refer to "Upgrade Kit" section for retroit information on the above option. 5. For calibration at test ixtures. Required for the gain-phase series-thru method. 03 | Keysight | E5061B Network Analyzer - Coniguration Guide Step 3. Choose hardware option (If not required, go to step 4) Option No. Description E5061B-1E5 1 |
Date | User | Rating | Comment |