File name 01630-90915 1630A D G Operating and Programming Oct85.pdf OPERATING AND PROGRAMMING MANUAL ~HEWLETT CP PACKARD [hp] OPERATING AND PROGRAMMING MANUAL HP LOGIC ANALYZERS MODELS 1630A/D/G This manual applies to Models 1630A/D (Option 007) and all 1630G instruments. It also applies to 1630A instruments serial prefixed 2424A and below, and 1630D instruments serial prefixed 2428A and below . HP Part Number 01630-90915 PRINTED : OCTOBER 1985 Microfiche Part Number 01630-90815 SAFETY SUMMARY The following general safety precautions must be observed during all phases of operation, service, and repair of this Instrument. Failure to comply with these precautions or with specific warnings elsewhere In this manual violates safety standards of design, manufacture, and intended use of the Instrument. Hewlett-Packard Company assumes no liability for the customer's failure to comply with these requirements. GROUND THE INSTRUMENT . To minimize shock hazard, the instrument chassis and cabinet must be connected to an electrical ground . The instrument is equipped with a three-conductor ac power cable . The power cable must either be plugged into an approved three-contact electrical outlet or used with a three-contact to two-contact adapter with the grounding wire (green) firmly connected to an electrical ground (safety ground) at the power outlet . The power jack and mating plug of the power cable meet International Electrotechnical Commission (IEC) safety standards . DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE . Do not operate the instrument in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard . KEEP AWAY FROM LIVE CIRCUITS . Operating personnel must not remove instrument covers . Component replacement and internal adjustments must be made by qualified maintenance personnel . Do not replace components with power cable connected. Under certain conditions, dangerous voltages may exist even with the power cable removed . To avoid injuries, always disconnect power and discharge circuits before touching them . DO NOT SERVICE OR ADJUST ALONE. Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present . USE CAUTION WHEN EXPOSING OR HANDLING THE CRT. Breakage of the Cathode-ray Tube (CRT) causes a high-velocity scattering of glass fragments (implosion) . To prevent CRT implosion, avoid rough handling or jarring of the instrument . Handling of the CRT shall be done only by qualified maintenance personnel using approved safety mask and gloves . DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT . Because of the danger of introducing additional h |
Date | User | Rating | Comment |