File information: | |
File name: | 5991-1401EN M8190A Arbitrary Waveform Generator - Configuration Guide c20140611 [11].pdf [preview 5991-1401EN M8190A Arbitrary Waveform Generator - Configuration Guide c20140611 [11]] |
Size: | 939 kB |
Extension: | |
Mfg: | Agilent |
Model: | 5991-1401EN M8190A Arbitrary Waveform Generator - Configuration Guide c20140611 [11] 🔎 |
Original: | 5991-1401EN M8190A Arbitrary Waveform Generator - Configuration Guide c20140611 [11] 🔎 |
Descr: | Agilent 5991-1401EN M8190A Arbitrary Waveform Generator - Configuration Guide c20140611 [11].pdf |
Group: | Electronics > Other |
Uploaded: | 28-08-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 5991-1401EN M8190A Arbitrary Waveform Generator - Configuration Guide c20140611 [11].pdf Keysight Technologies M8190A Arbitrary Waveform Generator Configuration Guide 02 | Keysight | M8190A Arbitrary Waveform Generator - Configuration Guide The following steps will guide you through configuring a turn key M8190A modular system. Step 1. Choose the number of channels per module. This is a hardware option and it is not upgradable later on (must choose one of the two options) Option No. Description M8190A-001 Arbitrary Waveform Generator module with 1 Channel M8190A-002 Arbitrary Waveform Generator module with 2 Channels Step 2. Choose the Sample Rate / Resolution combination per module (must choose one of the two options or both) Option No. Description M8190A-12G 12 GSa/s with 12 bit resolution M8190A-14B 14 bit resolution with 8 GSa/s Comment: It is also possible to choose both options for one module and select the run mode as required. The options are upgradable with the product number M8190AU-12G or M8190AU-14B.) Refer to Upgrade kits section on page 6 for retrofit information on the above options. 03 | Keysight | M8190A Arbitrary Waveform Generator - Configuration Guide Step 3. Choose the amount of memory per channel (If not required, go to step 4) Option No. Description M8190A-02G Upgrade from 128 MSa to 2 GSa Memory /Channel Comment: Select this option Qty 1 for a module with 1 Channel and Qty 2 for a 2-channel module. Refer to Upgrade kits section on page 6 for retrofit information on the above options. Step 4. Choose additional options per module (If not required, go to step 5; refer to Software upgrade section for retrofit information on the above option) Option No. Description M8190A-AMP Additional AC and DC Amplifier M8190A-SEQ Sequencer M8190A-FSW Fast Switching (requires Export Control License in conjunction with M8190A-12G) M8190A-DUC Digital Upconversion License for the M8190A Arbitrary Waveform Generator Comment: Option M8190A-FSW determines the minimum switching time between selected segments in sequence mode in 12 bit / 12GSa/s operation. For quoting option M8190A-FSW, options M8190A-12G and M8190A-SEQ are required. Option M8190A-FSW does not affect switching time in 14 bit / 8GSa/s mode, it is basically included in option M8190A-14B. Streaming is included in M8190A firmware version 3.x. Refer to Upgrade kits section on page 6 for retrofit information on the above options. Step 5. Choose multi-channel support (if not required, go to step 6) Option No. Description M8192A Sync |
Date | User | Rating | Comment |