File name E6630A_InstSW_Update E6630A Update Instructions c20130807 [6].pdf Instrument Software Update Instructions Agilent E6630A Wireless Connectivity Test Set Purpose The purpose of this document is to outline the instrument software update procedure for the E6630A, Wireless Connectivity Test Set. The advantages of updating the instrument software with the current revision include: 1. Keeps the instrument current and up to date. 2. Updates the advanced measurement applications where appropriate. 3. Updates the PC board FPGA software where appropriate. An update to the instrument software revision does not require a new license key for the measurement application(s), so long as the application(s) were licensed prior to the update. To determine what revision of instrument software is currently installed, press System, Show, System using the instruments virtual front panel. You can access the virtual front panel using a mouse and right "clicking" in the application window and selecting Utility Virtual Front Panel. Once in the show system screen look for the "Instrument S/W Revision" entry (for example: "A.13.85"). If the installed revision is the same as the latest revision on the web, there is no need to update the instrument software. Instrument Software Installation Note: This will only update the instrument software that currently resides on the C: drive of the instrument. It will not update the version that exists on the recovery partition. Because of this, if the recovery process is performed, the instrument will revert back to the instrument software revision that was originally shipped from the factory. Requirements To use this update procedure, the following requirements must be met: Instrument must be functioning properly before the update is attempted Must have a USB keyboard and mouse to perform tasks required to install update Must have the ability to login to the instrument as the administrator. Must have the ability to transfer a large file (~1G Byte) to the instrument being updated. File Download 1. Go to http://www.agilent.com/find/E6630A and go to the Technical Support section and select the Driver, Firmware & Software tab. 2. Download the executable file by clicking on the file link. Save the file to a location of your choice. If you do not have the ability to download files directly to the C: drive of the instrument being updated, store the file on a large capacity USB storage device for transfer to the instrument. (The file size is ~1 GByte.) Update Procedure The default user account is Instrument, which does not have the required permissions to install the instrument software updates. For the process outlined below, the user must be logged in as the Administrator. The automated instrument software upgrade process has an install wizard which removes the old software version and installs new software version without manual steps. The removal of the old software version and the installation of the new software version com |
Date | User | Rating | Comment |