Original:Thermistor Evaluation Using the Keysight B2911A 5990-7118EN c20130107 [5] 🔎
Descr: Agilent Thermistor Evaluation Using the Keysight B2911A 5990-7118EN c20130107 [5].pdf
Group:Electronics > Other
Uploaded:30-08-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name Thermistor Evaluation Using the Keysight B2911A 5990-7118EN c20130107 [5].pdf

Thermistor Evaluation Using the Agilent B2900A Series of SMUs Technical Overview Agilent B2901/02/11/12A Precision Source/Measure Unit Agilent B2901A Precision SMU, 1ch, 100 fA resolution, 210 V, 3 A DC/10.5 A pulse Agilent B2902A Precision SMU, 2ch, 100 fA resolution, 210 V, 3 A DC/10.5 A pulse Agilent B2911A Precision SMU, 1ch, 10 fA resolution, 210 V, 3 A DC/10.5 A pulse Introduction Agilent B2912A Precision SMU. 2ch, 10 fA resolution, 210 V, 3 A DC/10.5 A pulse The thermistor is a resistor with resistivity that varies as a function of temperature. Typical thermistor applications are thermal sensing and electric circuitry protection. However, the thermistor's sensitivity to temperature changes can work against measurement accuracy since Joule self-heating during measure- ment can alter device characteristics. This means that accurate thermistor characterization requires both precise low-current resistance measurement capability and pulsed bias measure- ment capability (to minimize tempera- ture change during measurement). The Agilent B2901/02/11/12A Precision Source/Measure Unit is a compact and cost-effective bench- top Source/Measure Unit (SMU) with the capability to output and measure both voltage and current. The B2900A Series of SMUs also supports a resistance measurement function that facilitates both low and Figure 1. Using the B2900A Series of SMUs to characterize a thermistor high resistance measurements. The B2900A Series of SMUs enables you to make a wide range of resistance that make it easy for you to begin Figure 1 illustrates the connections measurements more accurately and making productive measurements necessary for measuring a thermistor quickly than ever before. immediately. using a member of the B2900A Series of SMUs. The B2900A Series of SMUs In addition, the B2900A Series These features make the B2900A allows you to accurately and easily of SMUs comes with an intuitive Series of SMUs the best solution measure the resistance of thermistor. graphical user interface (GUI) and for accurate characterization of free PC-based application software thermistor and other devices. B2901/02/11/12A B2901/02/11/12A RLead High force IMeas High force IM

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : CROWN xls202

script execution: 0.07 s