File information: | |
File name: | HP 81110A with 81111A Perf. Test p97.pdf [preview HP 81110A with 81111A Perf. Test p97] |
Size: | 362 kB |
Extension: | |
Mfg: | Agilent |
Model: | HP 81110A with 81111A Perf. Test p97 🔎 |
Original: | HP 81110A with 81111A Perf. Test p97 🔎 |
Descr: | Agilent HP 81110A Document Set HP 81110A with 81111A Perf. Test p97.pdf |
Group: | Electronics > Other |
Uploaded: | 25-04-2021 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name HP 81110A with 81111A Perf. Test p97.pdf 5 5Agilent 81110A/'11A Performance Test 1 Agilent 81110A/'11A Performance Test Introduction Use the tests in this chapter if you want to check that the Agilent 81110A Pulse Generator Frame with the Agilent 81111A 165 MHz Output Channel(s) is working correctly. Before starting any testing allow all test equipment to warm up for at least 30 minutes. Conventions Used When referring to actions that you perform during the tests, the following conventions are used: FUNCTION This indicates that a labelled button must be pressed [MODE/TRG] This shows that a soft-key must be pressed. A soft- key is an unlabelled button whose label is shown on the display, and which can vary according to the job that the button is doing CONTINUOUS PULSES This is an option shown on the dis- play, and is selected by use of the vernier keys. It is shown in upper or lower case to match the case displayed. Test Results Tables Tables for entering the results of the tests are included at the end of this chapter. The tests are numbered and reference numbers for each Test Result (TR) are given in a small table at the end of each test. The reference number shows you where the actual results should be entered in the Test Results Tables. The Test Results tables at the end of the chapter should be photo- copied, and the Test Results entered on the copies. Then, if the tests need to be repeated, the tables can be copied again. 2 Agilent 81110A/'11A Performance Test Agilent 81110A/'11A Performance Test If Channel 2 has been fitted to your instrument, make an extra copy of the Test Results tables for entry of the results of tests on that channel. In this case, however, it is not necessary to repeat the Period tests, as these are common to both channels. Agilent 81110A/'11A Performance Test 3 Agilent 81110A/'11A Performance Test Recommended Test Equipment and Accessories The following tables list the recommended test equipment you need to perform all the tests in this chapter. You can use alterna- tive instruments if they meet the critical specifications given. The test set-ups and procedures assume you are using the recom- mended equipment. Test Equipment Model Critical Specifications Oscilloscope Agilent 54121T 20 GHz, 10 bit vertical resolution, Histogram or Oscilloscope Agilent 54750A + |
Date | User | Rating | Comment |