File information: | |
File name: | TEK CSA 7404_252C 7154_252C TDS 7404_252C 7254_252C 7154_252C 7104_252C 7054 Reference.pdf [preview TEK CSA 7404 252C 7154 252C TDS 7404 252C 7254 252C 7154 252C 7104 252C 7054 Reference] |
Size: | 1403 kB |
Extension: | |
Mfg: | Tektronix |
Model: | TEK CSA 7404 252C 7154 252C TDS 7404 252C 7254 252C 7154 252C 7104 252C 7054 Reference 🔎 |
Original: | TEK CSA 7404 252C 7154 252C TDS 7404 252C 7254 252C 7154 252C 7104 252C 7054 Reference 🔎 |
Descr: | Tektronix TEK CSA 7404_252C 7154_252C TDS 7404_252C 7254_252C 7154_252C 7104_252C 7054 Reference.pdf |
Group: | Electronics > Other |
Uploaded: | 14-05-2021 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name TEK CSA 7404_252C 7154_252C TDS 7404_252C 7254_252C 7154_252C 7104_252C 7054 Reference.pdf Reference CSA7000 Series Communications Signal Analyzers TDS7000 Series Digital Phosphor Oscilloscopes 071-7000-01 *P071700001* 071700001 To Use the Front Panel You can use the dedicated, front-panel knobs and buttons to do the most commonly performed operations. Turn INTENSITY to adjust waveform intensity. Push FastAcq to turn Fast Acquisition on and off. Push CURSORS to turn cursors on and off. Push PRINT to make a hard copy. Push DEFAULT SETUP to return settings to the default values. Push AUTOSET to quickly set the vertical, horizontal, and trigger controls for a usable display. Use the multipurpose knobs to control parameters selected from the screen interface. Push a FINE button to make small changes with a multipurpose knob. Push to turn the touch screen on and off. Push ZOOM to add a magnified graticule to the display. Push the HORIZ or VERT button to select the axis that you want to magnify. Use these knobs and buttons to set horizontal SCALE and POSITION for the waveforms. Push DELAY to turn on horizontal delay, and then use POSITION to set the delay time. Adjust RESOLUTION to change the number of acquired points in the waveform. Use these knobs and buttons to set the basic trigger parameters. Push ADVANCED to display a menu of additional trigger functions. Use these buttons to start and stop acquisition or start a single acquisition sequence. The ARM, READY, and TRIG'D lights show the acquisition status. Turn channel displays on and off, and adjust the channel POSITION and SCALE using dedicated knobs and buttons. Copyright E Tektronix, Inc. Beaverton, OR 97077 www.tektronix.com To Use the Screen Interface You can control all oscilloscope functions except the power switch using only the screen interface. Touch here to change to menu-bar Choose the Toolbar operation. Touch a button in the toolbar to display a control window at the bottom of the display. Touch a screen control to change a setting. Touch a numerical control to assign that control to a multipurpose knob. Turn the multipurpose knob to adjust the parameter value. Tou |
Date | User | Rating | Comment |