datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent Network analyzer evaluation of RF amplifier using Keysight B2961A 62A flyer 5991-1857EN [2]

Agilent Network analyzer evaluation of RF amplifier using Keysight B2961A 62A flyer 5991-1857EN [2] free download

Various electronics service manuals

File information:
File name:Network analyzer evaluation of RF amplifier using Keysight B2961A 62A flyer 5991-1857EN [2].pdf
[preview Network analyzer evaluation of RF amplifier using Keysight B2961A 62A flyer 5991-1857EN [2]]
Size:262 kB
Extension:pdf
Mfg:Agilent
Model:Network analyzer evaluation of RF amplifier using Keysight B2961A 62A flyer 5991-1857EN [2] 🔎
Original:Network analyzer evaluation of RF amplifier using Keysight B2961A 62A flyer 5991-1857EN [2] 🔎
Descr: Agilent Network analyzer evaluation of RF amplifier using Keysight B2961A 62A flyer 5991-1857EN [2].pdf
Group:Electronics > Other
Uploaded:20-06-2021
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name Network analyzer evaluation of RF amplifier using Keysight B2961A 62A flyer 5991-1857EN [2].pdf

Network analyzer evaluation of RF amplifier using Agilent B2961A/62A Agilent B2961A/B2962A 6.5 Digit Low Noise Power Source The Agilent B2961A/62A provides precise DC voltage or current for RF amplifier S-parameter measurements RF device Evaluation Using the Agilent B2961A/62A as a precise bias source To determine RF device performance, design and test engineers generally measure electrical The B2961A/62A's voltage source mode can be used to bias amplifiers. The applied bias cur characteristics such as S-parameters, frequency bandwidth, distortion, etc. rent will be the difference between the source and device voltages divided by the value of the Analyzers (network analyzers, spectrum analyzers, etc.) are commonly used to perform these mea- external bias resistor used. surements. Since most RF devices do not have an on-chip bias circuit, in addition to an analyzer a In situations where characteristics over temperature or multiple bias current values need to be voltage or current source is usually required to power and bias the device (in conjunction with a observed, it is more convenient to use the B2961A/62A's current source mode as opposed to bias resistor). This document outlines how to perform MMIC RF amplifier S-parameter measure- its voltage source mode since the device voltage will vary depending on both temperature and ments using the Agilent B2961A as the DC bias source. bias current The Agilent B2961A/62A's internal feedback mechanisms enable it to source precise and stable voltages and currents at their specified setting values despite varying load conditions. In addi Advantages of the B2961A/62A Low Noise Power Source tion, users can easily switch between voltage and current sourcing without changing any cable connections. A revolutionary power supply for precision low-noise voltage and current sourcing Superior 6.5 digit 100 nV/10 fA resolution Wide 210 V/3 A (10.5 A pulse) bipolar range Benefits

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -