datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Keithley 4072-1,0

Keithley 4072-1,0 free download

Various electronics service manuals

File information:
File name:4072-1,0.pdf
[preview 4072-1,0]
Size:12 kB
Extension:pdf
Mfg:Keithley
Model:4072-1,0 🔎
Original:4072-1,0 🔎
Descr: Keithley 2001M CDROM Digital Multimeters - Data Acquisition - Switch Systems Product Information CD_Content pdfs app_notes 4072-1,0.pdf
Group:Electronics > Other
Uploaded:01-08-2021
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 4072-1,0.pdf

Eliminating Common SCPI Errors Roger Chaplin May 17, 1993 There are three SCPI errors which occur more often than any others: -113, "Undefined header" -410, "Query INTERRUPTED" -420, "Query UNTERMINATED" This paper gives likely causes for these errors, and ideas for avoiding them. -113, "Undefined header" ------------------------ This error indicates that what you sent to the instrument did not contain a recognizable command name. The most likely causes for this are: 1. Missing space between the command and its parameter. There must be one or more spaces (blanks) between the command and its parameter. For example: :sens:volt:dc:rang100 wrong :sens:volt:dc:rang 100 right 2. Improper short or long form. Check the manual or the Quick Reference Guide for the correct command name. 3. Blanks (spaces) within the command name. Blanks are not permitted within the command name. For example: :syst:err? right :syst: err? wrong -410, "Query INTERRUPTED" ------------------------- This error occurs when you have sent a valid query to the instrument, then send it another command or query, or a Group Execute Trigger (GET) before it has had a chance to send the entire response message (including the line-feed/EOI terminator). The most likely causes are: 1. Sending a query to the instrument and then sending another command or query before reading the response to the first query. For example, the following sequence of commands will cause an error -410: send syst:err? send *opc? because you must read the response to syst:err? before sending another command or query. 2. Incorrectly configured IEEE 488 driver. The driver must be configured so that when talking on the bus it sends line-feed with EOI as the terminator, and when listening on the bus it expects line-feed with EOI as the terminator. See the reference manual for your particular IEEE 488 interface. -420, "Query UNTERMINATED" -------------------------- This error occurs when you addess the instrument to talk and it has nothing to say. The most likely causes are: 1. Not sending a query. You must send a valid query to the instrument before addressing it to talk. This is true even of measuring instruments, such as the Model 2001. You cannot get a reading from the 2001 until you send it a query. 2. Sending an invalid query. If you have sent a query and still get this error, make sure that the instrument is processing the query without error. For example, sending an ill-formed query which generates an error -113, "Undefined header" and then addressing the instrument to talk will generate an e

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Keithley 98932C(KPCMCIA_RS422_485S) - Keithley 6514RevA_DocSpec - Keithley Selector LowV-LowR - Keithley 2765 Thermistors - Keithley 052207 4ACS - Keithley 79480C(DASCard) - Keithley 3321RevB DocSpec -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Sanwa SANWA+CX506A

script execution: 0.02 s