File information: | |
File name: | 5990-5093EN InfiniiScan+ Event Identification Software for Infiniium Series Oscilloscopes - Data She [preview 5990-5093EN InfiniiScan+ Event Identification Software for Infiniium Series Oscilloscopes - Data She] |
Size: | 4289 kB |
Extension: | |
Mfg: | Agilent |
Model: | 5990-5093EN InfiniiScan+ Event Identification Software for Infiniium Series Oscilloscopes - Data She 🔎 |
Original: | 5990-5093EN InfiniiScan+ Event Identification Software for Infiniium Series Oscilloscopes - Data She 🔎 |
Descr: | Agilent 5990-5093EN InfiniiScan+ Event Identification Software for Infiniium Series Oscilloscopes - Data Sheet c20140813 [11].pdf |
Group: | Electronics > Other |
Uploaded: | 17-10-2021 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 5990-5093EN InfiniiScan+ Event Identification Software for Infiniium Series Oscilloscopes - Data She Keysight Technologies InfiniiScan+ Event Identification Software for Infiniium Series Oscilloscopes Data Sheet Now featuring more zones for zone qualify triggering Identify Signal Integrity Issues Quickly and Easily Today's digital signals are increasingly Consideration Classic methods InfiniiScan software complex. Designers of serial links and parallel busses want to quickly identify Number of events One, the hardware trigger Up to five different events or the signal anomalies in their designs. that can be monitored event same event on four channels Engineers have traditionally relied on simultaneously hardware triggering and deep memory Number of occurrences One, the occurrence at the Unlimited number of events to capture such illusive events. of that event that can hardware trigger point within the acquired time However, these classic methods fall be identified window short in some key areas. Variety of events that Approximately ten, fixed and Software descriptions provide can be identified limited by hardware triggering increased event definition The Keysight Technologies, Inc. capabilities flexibility InfiniiScan software allows you Maximum speed of Minimum input setting of Events as narrow as 70 ps can to use an oscilloscope to identify events that can be 300 ps, limited by hardware be isolated, limited only by signal integrity issues that hardware isolated triggering circuits sample rate resolution triggering is unable to find in your Difficulty in defining Requires triggering expertise. If you can see it, you can electronic designs. This innovative the proper setup to Many people end up pressing capture it using the zone qualify software scans through thousands of capture the event the Single key many times capability or any of InfiniiScan's acquired waveforms per second to help or spending hours scanning other power isolation you isolate signal anomalies, saving though acquired data. mechanisms you time and improving designs. Finding an event of Manually inspecting Scope scans the waveform interest in a deep waveforms is impractical, so you don't have to, and no memory capture as 1 M point of memory programming is required |
Date | User | Rating | Comment |