File information: | |
File name: | 24GS3-p13.pdf [preview 24GS3-p13] |
Size: | 31 kB |
Extension: | |
Mfg: | Philips |
Model: | 24GS3-p13 🔎 24GS3p13 |
Original: | 24GS3-p13 🔎 |
Descr: | Philips Monitor Monitor CD 2001[1].part02 Monitor CD 2001 E-MANUALS Philips crt 107b cdrom 24GS3-p13.pdf |
Group: | Electronics > Computer equipment > Monitors |
Uploaded: | 28-10-2021 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 24GS3-p13.pdf Warning and Notes 107B CM24 GSIII 13 Warnings Notes 1. Safety regulations require that the unit should be returned 1. The direct voltages and waveforms are average voltages. in its original condition and that components identical to They have been measured using the Service test software the original components are used. The safety components and under the following conditions : are indicated by the symbol . - Mode : 640 * 480 (31.5kHz / 60Hz) - Signal pattern : grey scale 2. In order to prevent damage to ICs and transistors, all - Adjust brightness and contrast control for the high-voltage flash-overs must be avoided. In order to mechanical mid-position (click position) prevent damage to the picture tube, the method shown in Fig. 1 should be used to discharge the picture tube. 2. The picture tube panel has printed spark gaps. Use a high-voltage probe and a multimeter (position DC-V). Each spark gap is connected between an electrode of the Discharge until the meter reading is 0 V (after approximately picture tube and the Aquadag coating. 30 seconds). 3. The semiconductors indicated in the circuit diagram(s) 3. ESD and in the parts lists are completely interchangeable per All ICs and many other semiconductors are sensitive to position with the semiconductors in the unit, irrespective electrostatic discharges (ESD). Careless handling during of the type indication on these semiconductors. repair can drastically shorten their life. Make sure that during repair you are connected by a pulse band with resistance to the same potential as the ground of the unit. Keep components and tools also at this same potential. 4. When repairing a unit, always connect it to the AC Power voltage via an isolating transformer. 5. Be careful when taking measurements in the high-voltage section and on the picture tube panel. 6. It is recommended that saferty goggles be worn when replacing the picture tube. 7. When making adjustments,use plastic rather than metal tools. This will prevent any short-circuit or the danger of a circuit becoming unstable. 8. Never replace modules or other components while the A unit is switched on. 9. Together with the defleciton unit, the picture tube is used Fig.1 as an integrated unit. Adjustment of this unit during repair is not recommended. 10. After repair, the wiring should be fastened in place with the cable clam |
Date | User | Rating | Comment |