File information: | |
File name: | 5992-0206EN N2804A and N2805A High Voltage Differential Probes - Data Sheet c20141009 [9].pdf [preview 5992-0206EN N2804A and N2805A High Voltage Differential Probes - Data Sheet c20141009 [9]] |
Size: | 637 kB |
Extension: | |
Mfg: | Agilent |
Model: | 5992-0206EN N2804A and N2805A High Voltage Differential Probes - Data Sheet c20141009 [9] 🔎 |
Original: | 5992-0206EN N2804A and N2805A High Voltage Differential Probes - Data Sheet c20141009 [9] 🔎 |
Descr: | Agilent 5992-0206EN N2804A and N2805A High Voltage Differential Probes - Data Sheet c20141009 [9].pdf |
Group: | Electronics > Other |
Uploaded: | 30-11-2021 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 5992-0206EN N2804A and N2805A High Voltage Differential Probes - Data Sheet c20141009 [9].pdf Keysight Technologies N2804A and N2805A High Voltage Differential Probes Data Sheet 02 | Keysight | N2804A and N2805A High Voltage Differential Probes - Data Sheet The N2804A and N2805A differential probes provide superior general-purpose differential signal measurements that are required for high-speed power measurements such as measuring characteristics of switching power devices, DC-DC converters or class D amplifiers, vehicle bus measurements, and high-speed digital system designs. Both probes are powered by the oscilloscope's AutoProbe interface. Both probes allow conventional earth-grounded Keysight oscilloscopes to be used for safe floating signal measurements. Because of outstanding common mode rejection ratio of the probes across the full frequency ranges, probes allow measurement of small differential signal in the presence of much larger common mode signals typically found in power measurements. The N2804A 300-MHz differential probe offers 100:1 attenuation ratio, allowing it to be used adequately for high voltage signal measurements. The differential probe has a differential input resistance of 4 M and low input capacitance of 4 pF to minimize circuit loading. The probe comes with a pair of extension leads (30 cm long) with a damping resistor built in to damp out the in-band resonance and provide flat frequency response even while using the extension leads and probe tip accessories. The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. This probe comes with an extensive set of probe tip accessories for use with small and large components in tight spaces. Figure 1. N2804A 300-MHz differential probe with Figure 2. N2805A 200-MHz differential probe with standard accessories. standard accessories. 03 | Keysight | N2804A and N2805A High Voltage Differential Probes - Data Sheet Product number N2804A N2805A Bandwidth* (-3dB) 300 MHz (without extension leads) 200 MHz 120 MHz (with extension leads) Rise time (calculated, 0.35/Tr, 10-90%) 1.167 ns 1.75 ns Attenuation 100:1 50:1 DC gain accuracy* (% of reading) |
Date | User | Rating | Comment |