File information: | |
File name: | MIL-STD-1553_mask_files_and_Application_Note MIL-STD-1553 Mask Files and Application Note.zip [preview MIL-STD-1553 mask files and Application Note MIL-STD-1553 Mask Files and Application Note] |
Size: | 2030 kB |
Extension: | zip |
Mfg: | Agilent |
Model: | MIL-STD-1553 mask files and Application Note MIL-STD-1553 Mask Files and Application Note 🔎 |
Original: | MIL-STD-1553 mask files and Application Note MIL-STD-1553 Mask Files and Application Note 🔎 |
Descr: | Agilent MIL-STD-1553_mask_files_and_Application_Note MIL-STD-1553 Mask Files and Application Note.zip |
Group: | Electronics > Other |
Uploaded: | 20-05-2022 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name MIL-STD-1553_mask_files_and_Application_Note MIL-STD-1553 Mask Files and Application Note.zip MIL-STD 1553 Eye-diagram Mask Testing Application Note Probing the Differential MIL-STD 1553 Bus MIL-STD 1553 eye-diagram mask testing is based on capturing and overlaying all "1" and "0" bits of the differential bus. The differential bus must be probed using a differential active probe. Agilent recommends using the N2791A 25-MHz differential active probe shown in Figure 1. The attenuation setting on the probe should be set to 10:1 (not 100:1). The output of the probe should be terminated into the scope's default 1-M input termination. Introduction Eye-diagram mask testing is used in a broad range of today's serial bus applications. An eye-diagram is basically an overlay of all bits captured by the scope to show when bits are valid and not valid. This provides a composite picture of the overall quality of a system's physical layer characteristics, which includes amplitude variations possibly due to transmission line affects, reflections, system noise, over-shoot, ringing, signal edge timing, and jitter. Eye-diagram mask testing can be performed on differential MIL-STD 1553 signals using an Agilent 3000 or 4000 X-Series oscilloscope licensed with the DSOX3AERO/ DSOX4AERO triggering and decode option (MIL-STD 1553 & ARINC 429), along with the DSOX3MASK/DSOX4MASK mask test option. Various MIL-STD 1553 mask files can be downloaded from Agilent's website at no charge. Save the appropriate MIL-STD 1553 mask files to your personal USB memory stick and then insert the memory stick into the scope's front-panel USB port. The following MIL-STD 1553 mask files are available: |
Date | User | Rating | Comment |