File name 2H9 005.pdf Service Bulletin SB Number: SB 2H9-005 Creation Date: 30/08/2010 Subject: Paper jam at the DP when scanning thick media in duplex Model: FS-1028MFP/1128MFP, DP-110 Phenomenon The paper jam may occur when using the DP to scan thick media in duplex. Cause This is due to insufficient paper transport force to reverse the paper. Solution 1. The projections have been added to the paper transport ribs at the cover PF. The cover PF is a component part of the parts cover PF assy SP and is not available is an individual part. Therefore please order the parts cover PF assy SP, when replacing the cover PF. 2. Due to the above mentioned changes the shape of the upper guide B 303LJ24280 has been changed. Therefore the 11 pieces of the PET film (Sheet upper guide A/sheet upper guide B) are no longer necessary, and have been discontinued. Parts No. Old Parts New Parts Description Q'TY Interchange- SP No. No. ability Old New Old New 1 - 303LJ94080 PARTS COVER PF ASSY SP - 1 - X O 3LJ94080 2 303LJ24071 303LJ24280 UPPER GUIDE B 1 1 X X O 3LJ24071 3LJ24280 Classification Entire stock rework X In-field modification by case No modification necessary In-field modification at next visit Field measure When the above mentioned phenomenon occurs, please replace the parts cover PF assy SP and the upper guide B with the latest type at the same time. Serial numbers of affected machines Serial numbers of affected units Type Serial number Type Serial number FS-1028MFP/DP QUV9Y04037 DP-110 QRP9Y02801 FS-1128MFP PAV8X02660 Machines produced after the above mentioned Units produced after the above mentioned serial serial numbers, should not have the above mentioned number, should not have the above mentioned phenomena. phenomena. KMIS Service Department, Kyocera Mita Europe Page of 2 |
Date | User | Rating | Comment |