Service Bulletin Ref. No. 2K3-0037 (C234)
September 7, 2012
Measure against the Developer Unit Detection Failure
(Measure against the Erroneous Display of "The developing
Subject
unit is not installed" or the Deformed Connector Terminal at
the Developer Unit)
FS-6025MFP, FS-6025MFP/B, FS-6030MFP, FS-6525MFP,
Model l:
FS-6530MFP
Topic
The detection PWB for the developer unit may be slightly slanted in counterclockwise direction depending on
structural variation since there is backlash between the detection PWB and its holder in the main unit.
If trying to install the developer unit to the main unit under this condition, the message "The developing unit is not
installed" may not disappear, or the connector terminal on the developer unit's rear side may be deformed due to
the contact with the connector holder on the detection PWB.
Field Measures
Please correct the angle of the detection PWB in the main unit and the deformed connector terminal on the
developing unit side by following the procedures described on the next pages.
Content of Changes (For more details, please refer to the page 3.)
(Temporary measures) - The detection PWB in the holder is attached while aligning it rightwards.
- It is checked at factory if the main unit can detect the detection PWB for the developer unit.
(Permanent measure) - The rib was added to the holder to attach the detection PWB in order to prevent the
detection PWB from slanting counterclockwise.
(Machine inner side)
NG condition OK condition
(View from the main unit inner side)
The connector terminal at the
developing unit may be
deformed by contact with the
connector on the detection
PWB attached while being Detection PWB slants Detection PWB
slanted when installing the counterclockwise. Holder
developer unit.
(Not individually supplied to the field)