Original:Symptom: Intermittent Failure Of The Power Supply 🔎
Descr:Television Technical Bulletin - pag. 1
Group:Electronics > Documentation
Uploaded:13-01-2007
User:salvacolnome
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name CTV991206_Bulletin_®_.pdf

CTV991206 TELEVISION TECHNICAL BULLETIN Month of Issue: December 1999 Classification: White Page 1 of 1 MODELS DV5105H DV5107H DV5132H SYMPTOM Intermittent failure of the power supply. CAUSE ACTION Various components. If Q702 immediately goes short circuit when the set is turned on, check that D716 has not gone short circuit or that T700 (chopper transformer) is not short circuit across pins 7 and 2. Note that D716 is connected across Q702 emitter earth return resistor, as this is only 0.22, D716 needs to be removed before testing. If the power supply works, but fails after being run on soak test, replace D708 and D709, also check that the main smoothing block (C705) has not got loose rivets. In some cases it is possible for the HT to rise significantly during standby, the normal value of the HT in standby is anywhere between 120VDC and 130VDC ( this rise is due to the line output load being removed). If this increases above 130VDC, there is a problem. Check the feedback circuit around the opto coupler and D751. Note that it is important that Q702 is replaced with the correct type or long term reliability problems will ensue (MJF18006). The HT voltage should be set to 113VDC on a blue screen (pull out the aerial and wait a few minutes - the screen will turn blue due to lack of line sync). REF NO C705 D708 D709 D716 D751 Q702 T700 DESCRIPTION Capacitor, 100uF 400V Diode, 1N4934 Diode, 1N4934 Diode, 1N4148 Diode Transistor, MJF18006 Chopper transformer PART NUMBER RC-EZ0104BMZZ RH-DX0519BMZZ RH-DX0519BMZZ RH-DX0045BMZZ RH-DX0226CEZZ RH-TX0119BMZZ RTRNZ0514BMZZ PRICE CODE AP AB AB AA AC AL AU Sharp Electronics (UK) Limited Reference AVW031299-1 Revision 1 White ­ Carry out as required, Yellow ­ Carry out as required and whenever the unit comes in for service, Red ­ Carry out on all units

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
sharp 20v-l80m - Sharp DV5161H - Sharp 51CS03H, 59CS03H, 66CS03H, 66CS05H, 51CS05H, 59CS05H, 59CSD8H, 66CSD8H - Sharp Sharp_Bulletins_7 - Sharp Sharp_Bulletins_6 - Sharp Sharp_Bulletins_8 - Sharp Sharp_Bulletins_3 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Top Power DC/DC Converters/TPTE0505S-1W

script execution: 0.03 s