datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:panasonic nv ds

panasonic nv ds free download

Digital photo camera, digital imaging - Sony, Olympus, Canon, Nikon, HP - service manual and repair information

File information:
File name:PanaTest.zip
Size:79 kB
Extension:
Mfg:panasonic
Model:nv ds 🔎
Original:
Descr:Abilitazione ingresso DV videocamere Panasonic
Group:Electronics > Consumer electronics > Photo > Digital cameras
Uploaded:02-01-2008
User:mauste
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:2
File name Cti.txt

PanaTest - program pro čtení/zápis kódů z/do paměti digitálních videokamer Panasonic. Pokud znáš správné kódy můžeš povolit DV in. Některé kódy jsou známy: (Zatím ověřeny u DA1 - tu mám doma) Address F8 / F7 / 30 NV-DA1 Codes En 62 / 00 / EF Codes Dis 62 / 18 / FF DS 33 Codes En 72 / 01 / 23 Codes Dis 72 / 19 / ?? EX 1 Codes En 82 / 01 / 23 Codes Dis 82 / 19 / ?? DX 100 Codes En A2 / 00 Codes Dis A2 / 18 DS 5 Codes En B2 / 00 Codes Dis B2 / 18 DS 1 Codes En C2 / A0 Codes Dis C2 / B8 DS 77 Codes En 42 / 01 / 23 Codes Dis 42 / 19 / ?? or Codes En 42 / 81 / 23 Codes Dis 42 / 99 / ?? Poznámka: Rozdíl mezi byty na adrese F7 pro zakázaný a povolený DVin je vždy 18h (podle této tabulky): Disable[F7] - Enable[F7] = 18h Toto může pomoci u kamer, pro které zatím nejsou známy kódy. ?? - kód neznám Co dále potřebuješ? PC - Windows 95/98 volný Com port Panasonic DVC still capture cable (jak ho zhotovit - http://www.cis.tu-graz.ac.at/wb/dvin/panautil.htm) Propoj PC a DVC, zapni DVC a přepni do VCR modu. Spusť PanaTest. Zaškrtni odpovídající Com port and klikni na Read. Uvidíš kódy adres F7 a F8. Adresa F8 slouží k ověření modelu, podle adresy F7 zjistíš jestli má kamera povolený nebo zakázaný DVin. Některé modely vyžadují i změnu kódu na adrese 30. (Na adrese 30 jsem vyzkoušel všech 256 možností při hledání správného kódu, na adrese F7 jsem zkoušel několik desítek možností, když jsem si myslel, že mám špatné kódy - kamera přežila, ale ty, pokud nejseš nadšenec, tak to radši nezkoušej!) Porovnej kódy s tabulkou nahoře. Jestliže jsi našel správné kódy můžeš je zapsat pomocí Write. Upozornění! Buď opatrný. Nesprávným zadáním kódu nebo adresy můžeš zničit kameru! Až budeš hotov, vypni kameru, počkej asi 5 sec. a znovu zapni. Pomocí tohoto programu můžeš provést výpis celé EEPROM (pouze pro VCR mod). Jestliže narazíš na problém nebo zjistíš něco nového pošli mi mail, prosím. Je to můj koníček, ne práce, takže nepočítej s nějakou velkou a rychlou podporou. 1999 Copyright Michal Krejcik [email protected] www.volny.cz/mkrejcik
File name Read.txt

WHAT IS PANATEST? PanaTest - the program for read/write codes from/to Panasonic DV Cam memory. If you know right codes and addresses you can enable DV in. CAMS AND CODES Some codes are known: (I get confirm about enabling all of these cam) Address F8 / F7 / 30 NV-DA1 Codes En 62 / 00 / EF Codes Dis 62 / 18 / FF DS 33 Codes En 72 / 01 / 23 Codes Dis 72 / 19 / 33 EX 1 Codes En 82 / 01 / 23 Codes Dis 82 / 19 / 33 DX 100 Codes En A2 / 00 Codes Dis A2 / 18 DS 5 Codes En B2 / 00 Codes Dis B2 / 18 DS 1 Codes En C2 / A0 Codes Dis C2 / B8 DS 77 Codes En 42 / 01 / 23 Codes Dis 42 / 19 / 33 or Codes En 42 / 81 / 23 Codes Dis 42 / 99 / 33 Note: I am sorry, but I don't know codes for DS8, DS11, DS99 and EX3. As soon as I'll have some information about them, I'll post it to my pages. Keep connection. WHAT DO YOU NEED? PC - Windows 95/98 (some reports that Windows NT and VirtualPC are working with PanaTest) free serial port Panasonic DVC still capture cable (how to make - http://www.cis.tu-graz.ac.at/wb/dvin/panautil.htm) HOW CAN I ENABLE (DISABLE) DVIN? Connect PC and DVC, turn DVC on and switch to VCR mode. Run PanaTest. Check Com port and click on Read button. You should see: 1. line - Address F8 (1st column) and its code (2nd column), this can be used for identification DVC (62 is DA1 and so on). 2. line - Address F7 (1st column - address field) and its code (2nd column - read code field), this says you if DV in enable or disable (look table above). If the connection is wrong, you'll see message box and XX in code fields. If you know right code, put it in field above Write button (3rd column - written code field) and you can write it to cam by clicking on Write button. Use only capital characters (A, B, C, D, E, F) or digits (0..9). If you put wrong character (for e.g. ff, b8, ...), you'll get warning message and non code is written to cam. Allways note address and code before and after writing! After succesfully writing to cam you'll see written code in read code field. Some models need to change code of address 30: Click on address on 2nd line (F7 in this case), delete it and put 30 in address field. Click on Read button. Note the code. Put right code (table above) in written code field and click Write. If you are finished, turn DVC off for no less then 5 sec. WARNING!!! Be carefull. If you use wrong codes or addresses you may damage your cam! Close Panatest and turn off cam before connecting or disconnecting, you may damage your port! Read my page DVin (http://www.volny.cz/mkrejcik) for detailed description. There you can find some FAQ and news about it. If you have one of cam with known codes and it seems not to work, first of all try to find problem in driver or software comming with your 1394



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Panasonic pv-dv400d - panasonic nv ds - panasonic nv ds - Panasonic DMC-FP1, FP2 - Panasonic DMC-LZ5 DMC-LZ4 DMC-LZ3 - Panasonic 2200 - Panasonic DMC-FZ50 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : conrad C-Phone

script execution: 0.02 s