datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Fluke 801

Fluke 801 free download

Measuring and test equipment,digital multimeters, analog multimeters, Fluke, Wavetek ... service manuals and repair information

File information:
File name:Fluke_801_Army.pdf
[preview 801]
Size:121 kB
Extension:pdf
Mfg:Fluke
Model:801 🔎
Original:
Descr:Army Calibration Procedure. 801, 801R, 801B, 801BR, 801B/AG, AN/USM-98, AN/USM-98A, AN/USM-98B Differential Voltmeters
Group:Electronics > Measuring equipment
Uploaded:27-01-2009
User:arnehoff
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name Fluke_801_Army.pdf

THIS COPY IS A REPRINT, WHICH INCLUDES CURRENT PAGES FROM CHANGES 1 THROUGH 5 *TB 9-6625-1866-50 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR DIFFERENTIAL VOLTMETERS AN/USM-98, AN/USM-98A, AND AN/USM-98B (JOHN FLUKE MODELS 801, 801R, 801B, 801BR, 801B/AG) Headquarters, Department of the Army, Washington, DC 19 September 1970 REPORTING OF ERRORS You can help improve this publication by calling attention to errors and by recommending improvements and stating your reasons for the recommendations. Your letter or DA Form 2028, Recommended Changes to Publications, should be mailed directly to Commander, U.S. Army Aviation and Missile Command, ATTN: AMSAM-TMD-EP, Redstone Arsenal, AL 35898-5000. FAX to DSN 7882313 (commercial 256-842-2313). A reply will be furnished directly to you. Paragraph SECTION I. GENERAL Purpose and scope... Reporting of equipment publication improvements ... Descriptive data ... General Instructions... Differences among models ... CALIBRATION OF DIFFERENTIAL VOLTMETERS AND/USM-98 (J-F 801 and 801R) Equipment and accessory required... Preliminary procedure... Dc VTVM and null range... 500-volt range and stability... 50-volt range ... 5-volt range ... 0.5-volt range ... 1 2 3 4 5 Page 2 2 2 3 4 II. 6 7 8 9 10 11 12 4 4 5 7 9 9 20 __________ *This bulletin supersedes TB 9-6625-994-50, 28 July 1969 and TB ORD 1026/981, 12 October 1964 including all changes. TB 9-6625-1866-50 Paragraph 13 14 Page 10 12 Voltage dividers ... Final procedure ... III. CALIBRATION OF DIFFERENTIAL VOLTMETERS AN/USM-98A AND AN/USM-98B (J-F 801B, J-F 801 BR, AND J-F 801B(AG) Equipment and accessories required ... Preliminary procedure... Dc VTVM and null range... 500-volt range and stability... 50-volt range ... 5-volt range ... 0.5-volt range ... Voltage dividers ... Final procedure ... SPECIFIC ITEM IDENTIFICATION Identification ... Secondary transfer calibration standards set... 15 16 17 18 19 20 21 22 23 24 25 12 12 13 16 16 17 18 19 20 20 20 SECTION I GENERAL 1. Purpose and Scope. This bull

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Fluke Fluke 2100A - Fluke 332A - Fluke 5100B - Fluke 5100B - Fluke 1900A - Fluke 27 - Fluke 45 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : rondo rondo202

script execution: 0.02 s