File information: | |
File name: | AL-1035 Instruction for Use of Adjustment Tool.pdf [preview AL-1035] |
Size: | 523 kB |
Extension: | |
Mfg: | Sharp |
Model: | AL-1035 🔎 AL1035 |
Original: | |
Descr: | AL-1035 Instruction for Use of Adjustment Tool |
Group: | Electronics > Computer equipment > Printers |
Uploaded: | 07-01-2016 |
User: | arko123a |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name AL-1035 Instruction for Use of Adjustment Tool.pdf Instruction for Use of Adjustment Tool Note: Be sure to install AL-1035 driver program in PC before using the adjustment tool. 4. Read Data from EEPROM Clicking [Read all NVRAM] button to read all data in the printer EEPROM and store them in PC. 1. Install Copy the adjustment tool folder under the root directory of Drive D and put the shortcut on the desktop. 5. Write Data to EEPROM 2. Connect Connect PC with AL-1035 through USB code and power on AL-1035. Clicking [Write all NVRAM] button to open the window for writing data to EEPROM. 3. Execution Double-click to open M140NVRamServiceTool.exe. "Device not found" dialogue appears when the cable is not connected correctly or the printer is not turned on. After the device connection is completed, "Welcome" screen appears. Clicking "SHARP AL-1035 NVRAM Service Tool" key to enter into Adjustment System Main Function Interface. AL-1035 Adjustment List 76 |