Procedure to Properly Zero the Model 6517A Keithley Instruments, Inc. 28775 Aurora Road Release Notes Cleveland, Ohio 44139 (440) 248-0400 www.keithley.com Introduction The following is the recommended procedure for completely zeroing the Model 6517A. Applies to: Model 6517A Electrometer User's Manual and Getting Started Manual. Substitute the following para- graphs for those in the 6517A User's Manual and the Getting Started Manual. 2.13.3 Zero correct The Z-CHK and REL keys work together to cancel (zero correct) any internal offsets that might upset accuracy for volts and amps measurements. Perform the following steps to zero correct the volts or amps function: 1. Select the V or I function. 2. Press Z-CHK to enable Zero Check. 3. Select the range that will be used for the measurement. 4. Press REL to zero correct the instrument (REL indicator will be lit and "Zcor" displayed). NOTE For the volts function, the "Zcor" message will not be displayed if guard was already enabled ("Grd" displayed). 5. Press Z-CHK to disable zero check. 6. Readings can now be taken in the normal manner. Note that the instrument will remain zeroed even if the instrument is upranged. If downranged, re-zero the instrument. To disable zero correct, press REL with zero check enabled. 2.13.4 "Properly zeroed" (as defined for instrument specifications) For taking measurements "when properly zeroed", per instrument specifications: 1. Perform the zero correct procedure described in section 2.13.3. 2. Provide a zero input from a calibration source, or short leads in V function, open leads in I function. 3. Press REL to null remaining measurement offsets. 4. Readings can now be taken in the normal manner. (REL indicator will remain on.) NOTE Repeat steps 1-4 whenever the measurement range is changed. To disable REL mode, press REL with zero check not enabled. NOTE These release notes are issued with C03 but are valid for all versions of firmware. 6517A-910-01 Rev. A / 9-02

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Keithley 98932C(KPCMCIA_RS422_485S) - Keithley 6514RevA_DocSpec - Keithley Selector LowV-LowR - Keithley 2765 Thermistors - Keithley 052207 4ACS - Keithley 79480C(DASCard) - Keithley 3321RevB DocSpec -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Samsung Samsung SP42W4HBX SP47W4HFX1 20030708181639593 j54a evapl-10 [SM]

script execution: 0.03 s