File information: | |
File name: | 5989-7819EN Infiniium 90000A Series Oscilloscopes - Data Sheet c20141005 [36].pdf [preview 5989-7819EN Infiniium 90000A Series Oscilloscopes - Data Sheet c20141005 [36]] |
Size: | 4386 kB |
Extension: | |
Mfg: | Agilent |
Model: | 5989-7819EN Infiniium 90000A Series Oscilloscopes - Data Sheet c20141005 [36] 🔎 |
Original: | 5989-7819EN Infiniium 90000A Series Oscilloscopes - Data Sheet c20141005 [36] 🔎 |
Descr: | Agilent 5989-7819EN Infiniium 90000A Series Oscilloscopes - Data Sheet c20141005 [36].pdf |
Group: | Electronics > Other |
Uploaded: | 31-01-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 5989-7819EN Infiniium 90000A Series Oscilloscopes - Data Sheet c20141005 [36].pdf Keysight Infiniium 90000 Series Oscilloscopes Data Sheet Engineered for unmatched real-time measurement accuracy Why choose Keysight oscilloscopes for your toughest high-speed measurement challenges? As an engineer you're no stranger to tough challenges that help you exceed your customer's needs and expectations. Deploying your next design successfully is even more difficult with today's high speed technologies. Data signal eye openings become smaller and measurement error from your oscilloscope becomes less tolerable. Keysight Technologies, Inc. is committed to providing the best measurement solutions for these critical challenges. The Keysight Infiniium 90000 Series oscilloscopes are engineered to give you unmatched real-time measurement accuracy so you can: 1. Use your jitter budget in your design, not on your oscilloscope. 2. Pass today's demanding compliance tests more quickly. 3. Debug your toughest designs with confidence. 90000A Series Infiniium oscilloscopes Model Real-time Maximum sampling Standard memory Maximum memory Noise floor at bandwidth on 4 ch rate on 4 ch 50 mV/div 91304A 13 GHz 40 GSa/s on 4 ch 20 Mpts on 4 ch 1 Gpts on 4 ch 1.73 mVrms 91204A 12 GHz 40 GSa/s on 4 ch 20 Mpts on 4 ch 1 Gpts on 4 ch 1.45 mVrms 90804A 8 GHz 40 GSa/s on 4 ch 20 Mpts on 4 ch 1 Gpts on 4 ch 1.15 mVrms 90604A 6 GHz 20 GSa/s on 4 ch* 20 Mpts on 4 ch 1 Gpts on 4 ch 0.98 mVrms 90404A 4 GHz 20 GSa/s on 4 ch* 20 Mpts on 4 ch 1 Gpts on 4 ch 0.79 mVrms 90254A 2.5 GHz 20 GSa/s on 4 ch* 20 Mpts on 4 ch 1 Gpts on 4 ch 0.64 mVrms *DSA model numbers come standard with 50 Mpts of memory on 4 ch. How much time span can I capture? Sampling Rate 20 Mpts of 50 Mpts of 100 Mpts of 200 Mpts of 500 Mpts of 1 Gpts of memory memory memory memory memory memory 40 GSa/s 500 s 1.25 ms 2.5 ms 5.0 ms 12.5 ms 25.0 ms 20 GSa/s 1 ms 2.5 ms 5.0 ms 10.0 ms 25.0 ms 50.0 ms Note: time span capture = memory depth x 1/ sampling rate 2 Engineered for unmatched real-time measurement accuracy. Use your jitter budget in your design, not on your oscilloscope. Keysight's Infiniium 90000 Series oscilloscopes offer the industry's lowest noise floor and most accurate real-time jitter measurements available on scope |
Date | User | Rating | Comment |