datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Keithley 500 915 01C

Keithley 500 915 01C free download

Various electronics service manuals

File information:
File name:500_915_01C.pdf
[preview 500 915 01C]
Size:856 kB
Extension:pdf
Mfg:Keithley
Model:500 915 01C 🔎
Original:500 915 01C 🔎
Descr: Keithley 500 500_915_01C.pdf
Group:Electronics > Other
Uploaded:20-02-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 500_915_01C.pdf

AIM5 Isolated Low-Level Analog Input Module The AIM5 Isolated Low-level Analog Input Module is designed to accept inputs from +5mV to *lOOmV, including signals from thermocouples. Isolated input permits the connection of signals with high common mode voltages--up to 500V DC or peak AC-- and provides normal mode input protection up to l3OV. Channel-to-chaimel isolation is 500V DC or peak AC. The input bandwidth is below 2Hz, reducing sensitivity to 50/60 cycle AC noise. There are four input channels on the AIM5 module, each with individually adjustable gain amplification. The module is shipped from the factory with a preset gain of xl00 volts/volt, appropriate for thermocouple types B,E,J,K,R,S, and T. This gain can be reset for each channel by changing the value of the gain-setting resistor. The AIM5 is equipped with cold junction reference circuitry, which allows accurate measurement of the junction temperature, eliminating the need for ice-bath reference junctions. The AIM5 may be placed in slots 3-10 of the baseboard (slots 2-10 if AMMl is used). To install the module, remove the top cover of the mainframe and insert the module in the desired slot with the component side facing the power supply. Place the AIM5 as far away from the power supply as possible to minimize noise or thermal effects. CAUTION: Always turn off the system power before installing or removing modules. To minimize the possibility of EM1 radiation, never operate the system with the top cover removed. Short the input terminals of unused channels together. User-Configured Components Overall gain is factory set to x100. Gain amplification for each channel can be modified by changing resistors in the locations provided on the AIM5 module card. Installing op- tional resistors provides current to voltage conversion, allowing connection of current loop inputs. All inputs are connected to a bank of screw terminals, with positive and negative (high and low) terminals for each of the four input channels (see Table 1 and Figure 1). Table 1. Summary of User-Configured Components Name Designation Function Switch 101 SlOl xl/xl00 gain (channel 0) Resistors R102, R106, RllO, R114 Per channel gain resistors Resistors User-installed Optional resistors for current to voltage conversion Screw Terminals J163 Input terminals for channels O-3 Document Number: 500-925-01 Rev. C AIM5-1 Fi

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Keithley 98932C(KPCMCIA_RS422_485S) - Keithley 6514RevA_DocSpec - Keithley Selector LowV-LowR - Keithley 2765 Thermistors - Keithley 052207 4ACS - Keithley 79480C(DASCard) - Keithley 3321RevB DocSpec -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : MARANTZ 4240

script execution: 0.03 s