datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Keithley 071316600(2290-5-RMK-1)

Keithley 071316600(2290-5-RMK-1) free download

Various electronics service manuals

File information:
File name:071316600(2290-5-RMK-1).pdf
[preview 071316600(2290-5-RMK-1)]
Size:159 kB
Extension:pdf
Mfg:Keithley
Model:071316600(2290-5-RMK-1) 🔎
Original:071316600(2290-5-RMK-1) 🔎
Descr: Keithley Kits 071316600(2290-5-RMK-1).pdf
Group:Electronics > Other
Uploaded:26-02-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 071316600(2290-5-RMK-1).pdf

Model 2290-5-RMK-1 Keithley Instruments, Inc. 28775 Aurora Road Single Rack-Mount Kit Instructions Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Introduction This document provides instructions for the Model 2290-5-RMK-1 single fixed rack-mount kit. The kit contains mounts needed to install one Model 2290-5 High Voltage Power Supply in a standard 19-inch rack. Hardware is included to attach the instrument to the rack ears (use existing hardware to mount the assembly into the rack). Parts list The parts list below contains a description of the parts supplied with the Model 2290-5-RMK-1 single fixed rack-mount kit. Item number Quantity Description Use 1 2 Handle Attached to rack ears 2 4 Truss head screws Screws removed from the instrument to secure rack ears to instrument 3 4 Flat head screws Handle 4 1 Rack ear Instrument side rack ear 5 1 Rack ear Blank side rack ear 071316600 *P071316600* 1 2290-5 kV Single Rack Mount Kit Installation The next figure provides an exploded view of the rack mounting kit, the instrument, and the rack face. Step-by-step assembly and mounting instructions are given below. Before installing the instrument in the rack, be sure that the rack angle bracket or shelf is in place and adjusted to accept and support the instrument. Under no circumstances should the instrument's entire weight be supported solely by the hardware and brackets supplied in the mounting kit. 1. Mount handles (1) to both rack ears (4 and 5) securing each handle with two flat head screws (3). 2. Determine which side of the rack (left or right) will contain the instrument. 3. Install the instrument side rack ear (4) to the instrument and secure with two truss head screws that were removed from the instrument (2). The next figure shows the instrument is mounted on the left side of the rack. When you remove the truss head screws to install the rack ears, you will need to re-use the screws to secure the rack ears on the outside edge of each instrument. 4. Install the blank side rack ear (5) and secure with two truss head screws that were removed from the instrument (2). 5. Install assembly (instrument and installed rack ears) in the rack. Secure the assembly with existing hardware (see the next figures). Figure 1: Model 2290-5 single rack mount kit installation 2

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Keithley 98932C(KPCMCIA_RS422_485S) - Keithley 6514RevA_DocSpec - Keithley Selector LowV-LowR - Keithley 2765 Thermistors - Keithley 052207 4ACS - Keithley 79480C(DASCard) - Keithley 3321RevB DocSpec -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : AOC 1-HP

script execution: 0.03 s