datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Keithley 7153 901 01A

Keithley 7153 901 01A free download

Various electronics service manuals

File information:
File name:7153_901_01A.pdf
[preview 7153 901 01A]
Size:2642 kB
Extension:pdf
Mfg:Keithley
Model:7153 901 01A 🔎
Original:7153 901 01A 🔎
Descr: Keithley 71xx 7153_901_01A.pdf
Group:Electronics > Other
Uploaded:08-03-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 7153_901_01A.pdf

Model 7153 High Voltage Low Current Matrix Card Instruction Manual Contains Operating and Servicing Information Model 7153 High Voltage Low Instruction Manual 0 1990, Keithley Instruments, Inc. Test Instrumentation Croup All rights reserved. Cleveland, Ohio, U.S.A. November 1990, First Printing Document Number: 7153.YOLRev. A SAFETY PRECAUTIONS The following safety precautions should be observed before using the Model 7153 and the associated instruments. This matrix card is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read over this manual carefully before using the card. ALWAYS remove power from the entire system (mainframe, test instru- ments, DUT, etc.) and discharge any capacitors before doing any of the following: 1. Installing or removing the matrix card from the mainframe. 2. Connecting or disconnecting cables from the matrix card. Exercise extreme caution when a shock hazard is present at the test fixture. User-supplied lethal voltages may be present on the fixture or the connec- tor jack. The American National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 30V RMS or 42.4V peak are present. A good safety practice is to expect that hazardous volt- age is present in any unknown circuit before measuring. Do not exceed 1300V between any two pins or between any pin and chas- sis ground. Inspect the connecting cables and test leads for possible wear, cracks, or breaks before each use. For maximum safety, do not touch the test fixture, test cables or any instru- ments while power is applied to the circuit under test. Do not touch any object which could provide a current path to the com- mon side of the circuit under test or power line (earth) ground. Do not exceed the maximum signal levels of the test fixture, as defined in the specifications and operation section of this manual. Do not connect the matrix card (or any other instrumentation) to humans. Do not connect the matrix card directly to unlimited power circuits. This product is intended to be used with impedance limited sources. NEVER connect the tmatrix card directly to AC mains. When connecting sources, install protective devices to limit fault current and voltage to the card. The chassis connections must only be used as shield connections for measuring circuits; NOT as safety earth ground connections. The outer shields (including the triax connector shells) of the Model 7153-TRX are not connected to safety earth ground. NEVER apply more than 30V to these shields. To prevent voltages from bein

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Keithley 98932C(KPCMCIA_RS422_485S) - Keithley 6514RevA_DocSpec - Keithley Selector LowV-LowR - Keithley 2765 Thermistors - Keithley 052207 4ACS - Keithley 79480C(DASCard) - Keithley 3321RevB DocSpec -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : APC SU10000

script execution: 0.03 s