File information: | |
File name: | RS265TDBP.pdf [preview RS265TDBP] |
Size: | 2422 kB |
Extension: | |
Mfg: | Samsung |
Model: | RS265TDBP 🔎 |
Original: | RS265TDBP 🔎 |
Descr: | Samsung Refridgerators RS265TDRS Service Tip RS265TDBP.pdf |
Group: | Electronics > Other |
Uploaded: | 09-03-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name RS265TDBP.pdf 6/21/13 Dr Error Code Chart FZ SENSOR ERROR- The sensor is read as open or shorted, 1 E Error check the wiring connections in the respective compartment and at the Main PCB R SENSOR ERROR- The sensor is read as open or shorted, check 2 E Error the wiring connections in the respective compartment and at the Main PCB FZ DEF SENSOR ERROR- The sensor is read as open or shorted, 4 E Error check the wiring connections in the respective compartment and at the Main PCB R DEF SENSOR ERROR-- The sensor is read as open or shorted, 5 E Error check the wiring connections in the respective compartment and at the Main PCB AMBIENT-SENSOR ERROR- The sensor is read as open or 6 E Error shorted, check the wiring connections in the respective compartment and at the Main PCB HUMIDITY-SENSOR ERROR- The sensor is read as open or 13 E Error shorted, check the wiring connections in the respective compartment and at the Main PCB IM SENSOR ERROR-- The sensor is read as open or shorted, 14 E Error check the wiring connections at the Icemaker, the ice room and at the Main PCB FZ FAN ERROR-The Freezer Fan motor is read as not connected or 21 E Error the fan has stopped, check the wiring connections in the freezer and at the Main PCB R FAN ERROR-The Ref. Fan motor is read as not connected or the 22 E Error fan has stopped, check the wiring connections in the freezer and at the Main PCB C-FAN ERROR-The Comp. Fan motor is read as not connected or 23 E Error the fan has stopped, check the wiring connections in the freezer and at the Main PCB FZ DEF FUNCTION ERROR-The freezer defrost heater is read as 24 E Error open or the heater has been heating continuously for more than 80 minutes. R DEF FUNCTION ERROR-The refrigerator defrost heater is read 25 E Error as open or the heater has been heating continuously for more than 80 minutes. ICE Maker function Error- Ice Maker In FZ Function will put out 26 E Error an error IM FUNCTION ERROR- The Icemaker release heater reads as open 39 E Error circuit or the ice rake did not return to the home position MAIN<->LCD COMM ERROR- The Main PCB and the LCD display 41 E Error are not communicating properly verify the wiring at both PCB's COMP STARTING FAILURE- The compressor did not start 81 E Error properly, check for an overload condition COMP ABNORMAL CURRENT DETECTION -Excessive current 83 E Error detected at the Compressor check the compressor windings for shorts COMP MOTOR LOCKED OVER RPM ERROR- Compressor Over 84 E Error speed er |
Date | User | Rating | Comment |