6/21/13 Dr Error Code Chart FZ SENSOR ERROR- The sensor is read as open or shorted, 1 E Error check the wiring connections in the respective compartment and at the Main PCB R SENSOR ERROR- The sensor is read as open or shorted, check 2 E Error the wiring connections in the respective compartment and at the Main PCB FZ DEF SENSOR ERROR- The sensor is read as open or shorted, 4 E Error check the wiring connections in the respective compartment and at the Main PCB R DEF SENSOR ERROR-- The sensor is read as open or shorted, 5 E Error check the wiring connections in the respective compartment and at the Main PCB AMBIENT-SENSOR ERROR- The sensor is read as open or 6 E Error shorted, check the wiring connections in the respective compartment and at the Main PCB HUMIDITY-SENSOR ERROR- The sensor is read as open or 13 E Error shorted, check the wiring connections in the respective compartment and at the Main PCB IM SENSOR ERROR-- The sensor is read as open or shorted, 14 E Error check the wiring connections at the Icemaker, the ice room and at the Main PCB FZ FAN ERROR-The Freezer Fan motor is read as not connected or 21 E Error the fan has stopped, check the wiring connections in the freezer and at the Main PCB R FAN ERROR-The Ref. Fan motor is read as not connected or the 22 E Error fan has stopped, check the wiring connections in the freezer and at the Main PCB C-FAN ERROR-The Comp. Fan motor is read as not connected or 23 E Error the fan has stopped, check the wiring connections in the freezer and at the Main PCB FZ DEF FUNCTION ERROR-The freezer defrost heater is read as 24 E Error open or the heater has been heating continuously for more than 80 minutes. R DEF FUNCTION ERROR-The refrigerator defrost heater is read 25 E Error as open or the heater has been heating continuously for more than 80 minutes. ICE Maker function Error- Ice Maker In FZ Function will put out 26 E Error an error IM FUNCTION ERROR- The Icemaker release heater reads as open 39 E Error circuit or the ice rake did not return to the home position MAIN<->LCD COMM ERROR- The Main PCB and the LCD display 41 E Error are not communicating properly verify the wiring at both PCB's COMP STARTING FAILURE- The compressor did not start 81 E Error properly, check for an overload condition COMP ABNORMAL CURRENT DETECTION -Excessive current 83 E Error detected at the Compressor check the compressor windings for shorts COMP MOTOR LOCKED OVER RPM ERROR- Compressor Over 84 E Error speed er

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Samsung TORINO 2 NP Q70 (2) - Samsung LG-RT-44NZ21RBService Manual.part3 - Samsung Spinpoint F1 III - Samsung LG-RT-44NZ21RBService Manual.part4 - Samsung le-26a41b.part1 - Samsung Cover - Samsung Cover -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Behringer T-1

script execution: 0.05 s