Error Code Chart
FZ SENSOR ERROR- The sensor is read as open or shorted,
1 E Error check the wiring connections in the respective compartment and
at the Main PCB
R SENSOR ERROR- The sensor is read as open or shorted, check
2 E Error the wiring connections in the respective compartment and at the
Main PCB
FZ DEF SENSOR ERROR- The sensor is read as open or shorted,
4 E Error check the wiring connections in the respective compartment and
at the Main PCB
R DEF SENSOR ERROR-- The sensor is read as open or shorted,
5 E Error check the wiring connections in the respective compartment and
at the Main PCB
AMBIENT-SENSOR ERROR- The sensor is read as open or
6 E Error shorted, check the wiring connections in the respective
compartment and at the Main PCB
HUMIDITY-SENSOR ERROR- The sensor is read as open or
13 E Error shorted, check the wiring connections in the respective
compartment and at the Main PCB
IM SENSOR ERROR-- The sensor is read as open or shorted,
14 E Error check the wiring connections at the Icemaker, the ice room and at
the Main PCB
FZ FAN ERROR-The Freezer Fan motor is read as not connected or
21 E Error the fan has stopped, check the wiring connections in the freezer
and at the Main PCB
R FAN ERROR-The Ref. Fan motor is read as not connected or the
22 E Error fan has stopped, check the wiring connections in the freezer and at
the Main PCB
C-FAN ERROR-The Comp. Fan motor is read as not connected or
23 E Error the fan has stopped, check the wiring connections in the freezer
and at the Main PCB
FZ DEF FUNCTION ERROR-The freezer defrost heater is read as
24 E Error open or the heater has been heating continuously for more than 80
minutes.
R DEF FUNCTION ERROR-The refrigerator defrost heater is read
25 E Error as open or the heater has been heating continuously for more than
80 minutes.
ICE Maker function Error- Ice Maker In FZ Function will put out
26 E Error
an error
IM FUNCTION ERROR- The Icemaker release heater reads as open
39 E Error
circuit or the ice rake did not return to the home position
MAIN<->LCD COMM ERROR- The Main PCB and the LCD display
41 E Error
are not communicating properly verify the wiring at both PCB's
COMP STARTING FAILURE- The compressor did not start
81 E Error
properly, check for an overload condition
COMP ABNORMAL CURRENT DETECTION -Excessive current
83 E Error detected at the Compressor check the compressor windings for
shorts
COMP MOTOR LOCKED OVER RPM ERROR- Compressor Over
84 E Error
speed error check for low refrigerant levels
COMP UNDER VOLTAGE- Low voltage to the compressor Check
85 E Error
the DC supply from the Main PCB
COMP OVER VOLTAGE- Over voltage to the compressor Check
86 E Error
the DC supply from the Main PCB