File name err-msg.PDF Appendix B: Status and Error Messages This appendix describes the status and error messages that appear on the CTS850 display. Status messages are statements about actions the CTS850 has completed. Status messages appear during normal operation. Error messages are statements about actions the CTS850 was unable to complete. Error messages appear when the CTS850 is unable to perform a requested action. Status Messages Autoscan complete. The CTS850 has successfully completed the Autoscan sequence. Burst pointer movement transmitted. The POINTER ACTION button was pressed with the Pointer Control set to Burst. Disk root directory read. The CTS850 has successfully read the disk directory. Factory settings restored, non-volatile settings cleared. This message appears when the instrument is turned on after it was turned off during a state change. The instrument settings were corrupted during the shutdown and so the factory default settings were loaded at turn-on and all information stored in RAM was cleared. File has been deleted. The CTS850 has successfully deleted the selected file. Hardcopy complete. The CTS850 has successfully completed a printout. CTS850 SDH Test Set User Manual B 1 Appendix B: Status and Error Messages Instrument factory reset complete. The recall of default factory settings, from the RECALL INSTRUMENT SETUPS page, was completed successfully. Instrument returned to previous setup. This message appears if you select Cancel while an Autoscan is in progress. Instrument setup for received signal. The CTS850 has completed an Autoscan and has changed its settings to match those of the received signal. Internal diagnostics completed. An instrument self test has been initiated and completed successfully. No Setup file with '.SET' extension found. You selected the Disk action on the RECALL INSTRUMENT SETUPS page and no instrument setup files were found on the disk. Previous power down instrument state restored. This message appears when the CTS850 turns on. It means that the settings in effect when the CTS850 was last turned off have been successfully restored. Reading disk... The CTS850 is reading the disk directory. Recall of instrument setup complete. This message confirms that the recall of an instrument setup was successfully completed. Recall of measurement results/histories complete. The CTS850 has successfully recalled the selected results from disk. Recall of pass/fail test complete. The CTS850 has successfully recalled the selected pass/fail test from disk. Save of instrument setup co |
Date | User | Rating | Comment |