File information: | |
File name: | 130A_901_01C.pdf [preview 130A 901 01C] |
Size: | 587 kB |
Extension: | |
Mfg: | Keithley |
Model: | 130A 901 01C 🔎 |
Original: | 130A 901 01C 🔎 |
Descr: | Keithley 130_131 130A_901_01C.pdf |
Group: | Electronics > Other |
Uploaded: | 21-03-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 130A_901_01C.pdf APPLICATIONS DEPT. mmm 28775 AURORA ROAD CLEVELAND, OHIO 44139 U.S.A. Model 130A/131 1216) 248-0400 Publication Date: June 1984 Document Number: 130A-901-01C WARRANTY Keithley Instruments, Inc. warrants this product to be free from defects in material and workmanship for a period of two years from date of ship- ment. During the warranty period, we will, at our option, either repair or replace any product that proves to be defective. To exercise this warranty, write or call your local Keithley representative, or contact Keithley headquarters in Cleveland, Ohio. You will be given prompt assistance and return instructions. Send the instrument, transportation prepaid, to the indicated service facility. Repairs will be made and the instrument returned, transportation prepaid. Repaired products are warranted for the balance of the original warranty period, or at least 90 days. LIMITATION OF WARRANTY This warranty does not apply to defects resulting from unauthorized modification or misuse of any product or part. This warranty also does not apply to fuses, batteries, or damage from battery leakage. This warranty is in lieu of all other warranties, expressed or implied, in- cluding any implied warranty of merchantability or fitness for a particular use. Keithley Instruments, Inc. shall not be liable for any indirect, special or consequential damages. STATEMENT OF CALIBRATION This instrument has been inspected and tested in accordance with specifications published by Keithley Instruments, Inc. The accuracy and calibration of this instrument are traceable to the National Bureau of Standards through equipment which is calibrated at planned intervals by comparison to certified standards maintained in the Laboratories of Keithley Instruments, Inc. S PECIFICAT10 NS DC VOLTS ACCURACY (2 YEARS) +(%rdg + counts) RANGE RESOLUTION 1E0-2E0C 200mV 100 pv 2 v 1mV 20 v 10mV +(0.25% + 11 200 v 100mV 1000 v 1 v M A X I M U M ALLOWABLE INPUT: 1OOOV DC or peak AC non-switched, 750V peak switched. INPUT RESISTANCE: 10MR. NORMAL MODE REJECTION RATIO: Greater than 46dB at 50Hz, 60Hz. C O M M O N MODE REJECTION RATIO: Greater than lOOdB at DC, 50Hz and 6OHz (1kQ unbalance]. AC VOLTS ACCURACY (2 YEARS)" f (Yordg+ counts) FREQUENCY RANGE RESOLUTION 1Eo-28OC RANGE 200mV 100 pv 2 v 1mV 20 v 10mV +(l% + 31 45Hz-500Hz 200 v 100mV 750 V 1 v M A X I M U M ALLOWABLE INPUT: lOOOV |
Date | User | Rating | Comment |