For internal use only PHILIPS
ISSUE AS99.07 (99-09-28)
Published by:
Service Department Audio Systems
LINE OF BUSINESS AUDIO SYSTEMS
SERVICE NEWSLETTER
07.01 TYPENUMBER(S): FW350C/34, FW390C/34, FW398C/34
SYMPTOM : IRIS CODE 1 2 1 2
FM1 range is lost when the set is switched off.
CURE : The FM1 range (65.81-74MHz) can be turned on via the procedure
published in Service Newsletter AS99.05.03.
However, due to a software problem, some sets disable the FM1
range again when the set is switched off.
The problem can be resolved by replacing the microprocessor by the
new version "23". The ordering code reads 9965 000 01676.
REMARKS :
07.02 TYPENUMBER(S): FW754P, FW765P, FW795W
INFORMATION : Corrections to the Service Manual, partslist
1. Service code for Rucksack of "Power4 Module" should read:
4822 256 10575 Rucksack 4 Channel
2. FW795W/37 only: Service code for item 224
(Exploded view, page 14-2) should read:
4822 454 13447 Orn Display DPL only for FW795W/37
REMARKS :