4009UBINVERTING TYPE 4010BNON INVERTING TYPE
. . . . . . . . .
CMOS TO DTL/TTL HEX CONVERTER HIGH-TO-LOW LEVEL LOGIC CONVERSION MULTIPLEXER: 1-TO-6 OR 6-TO-1 HIGH"SINK" AND "SOURCE" CURRENT CAPABILITY 5V, 10V AND 15V PARAMETRIC RATINGS MAXIMUM INPUT CURRENT OF 100 µA AT 18V OVER FULL PACKAGE AND TEMPERATURE RANGE; o 100nA AT 18V AND 25 C 100% TESTED FOR QUIESCENT CURRENT AT 20V MEETS ALL REQUIREMENTS OF JEDEC TENTATIVE STANDARD N. 13A, " STANDARD SPECIFICATIONS FOR DESCRIPTION OF B SERIES CMOS DEVICES "
non-inverting Hex Buffer/Converters, respectively. Both devices can be used as CMOS to TTL or DTL logic-level converters, as current "sink" or "source" drivers or as multiplexer (1 to 6). 4049UB and 4050B are prefered replacements for 4009UB and 4010B, respectively, in buffer applications.
EY (Plastic Package)
F (Ceramic Package)
DESCRIPTION The HCC4009UB/4010B (extended temperature range) and the HCF4009UB/4010B (intermediate temperature range) are monolithic integrated circuits available in 16-lead dual in line plastic or ceramic packages and plastic micropackage. The HCC/HCF4009UB/4010B are inverting and PIN CONNECTIONS 4009UB 4010B
M1 (Micro Package) C1 (Chip Carrier)
ORDER CODES : HCCXXXXBF HCFXXXXBM1 HCFXXXXBEY HCFXXXXBC1
September 1988
1/13
HCC/HCF4009UB HCC/ HCF4010B
SCHEMATIC DIAGRAM: COS/MOS TO DTL OR TTL CONVERTER (1 of 6 identical units)
4009UB
4010B
Connect VCC to DTL or TTL supply and VDD to COS/MOS supply
ABSOLUTE MAXIMUM RATING
Symbol VDD * Vi II Ptot Parameter Supply Voltage: HCC Types HCF Types Input Voltage DC Input Current (any one input) Total Power Dissipation (per package) Dissipation per Output Transistor for Top = Full Package Temperature Range Operating Temperature: HCC Types HCF Types Storage Temperature Value -0.5 to +20 -0.5 to +18 -0.5 to VDD + 0.5 ± 10 200 100 -55 to +125 -40 to +85 -65 to +150 Unit V V V mA mW mW
o o
Top Tstg
C C o C
Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress ratingonly and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for external periods may affect device reliability. * All voltage values are referred to VSS pin voltage.
RECOMMENDED OPERATING CONDITIONS
Symbol VDD VI Top Parameter Supply Voltage: HCC Types HCF Types Input Voltage Operating Temperature: HCC Types HCF Types Value 3 to 18 3 to 15 0 to VDD -55 to +125 -40 to +85 Unit V V V
o o
C C
2/13
HCC/HCF4009UB HCC/HCF4010B
STATIC ELECTRICAL CHARACTERISTICS (over recommended operating conditions)
Symbol IL Parameter Quiescent Current VI (V) Test Conditios VO |IO| VDD (V) (µA) (V) 5 10 15 20 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 5 5 10 15 5 5 10 15 5 10 15 5 10 15 18 Any Input Value TLOW * 25 oC Min. Max. Min. Typ. 1 0.02 2 0.02 4 0.02 20 0.04 4 0.02 8 0.02 16 0.02 4.95 4.95 9.95 9.95 14.95 14.95 0.05 0.05 0.05 4 4 8 8 12.5 12.5 3.5 3.5 7 7 11 11 1 2 2.5 1.5 3 4 -1 -0.8 -1.6 -0.25 -0.2 -0.4 -0.55 -0.45 -0.9 -1.65 -1.5 -3 -0.9 -0.8 -1.6 -0.23 -0.2 -0.4 -0.5 -0.45 -0.9 -1.6 -1.5 -3 3.75 3 4 10 8 10 30 24 36 3.6 3 4 0.96 8 10 40 24 36 ±0.1 ±10-5 15 5 THIGH * Min. Max. 30 60 120 600 30 60 120 4.95 9.95 14.95 0.05 0.05 0.05 0.05 0.05 0.05 4 8 12.5 3.5 7 11 1 1 2 2 2.5 2.5 1.5 1.5 3 3 4 4 -0.58 -0.15 -0.33 -1.1 -0.65 -0.18 -0.38 -1.25 2.1 5.6 16 2.4 6.4 1.9 ±0.1 22.6 7.5 ±1 Unit
V OH
VOL
VIH
0/5 0/10 0/15 0/20 0/5 HCF 0/10 Types 0/15 Output High 0/5 Voltage 0/10 0/15 Output Low 5/0 Voltage 10/0 15/0 Input High Voltage (4009UB) HCC Types Input High Voltage (4010B) Input Low Voltage (4009UB) Input Low Voltage (4010B) Output Drive Current 0/5 0/5 0/10 0/15 0/5 0/5 0/10 0/15 0/5 0/10 0/15 0/5 0/10 0/15
Max. 1 2 4 20 4 8 16
µA
V
V
VIH
V IL
V IL
IOH
HCC Types
HCF Types IOL Output Sink Current
HCC Types HCF Types
0.5 1 1.5 4.5 9 13.5 4.5 9 13.5 0.5 1 1.5 2.5 4.6 9.5 13.5 2.5 4.6 9.5 13.5 0.4 0.5 1.5 0.4 0.5 1.5
V
V
V
V
mA
mA
IIH, IIL CI
Input Leakage 0/18 Current Input 4009UB Capacitance 4010B
µA pF
* TLOW = -55 oC for HCC device: -40 oC for HCF device. * THIGH = +125 oC for HCC device: +85 oC for HCF device. The Noise Margin for both "1" and "0" level is: 1V min. with VDD = 5 V, 2 V min. with VDD = 10 V, 2.5 V min. with VDD = 15 V
3/13
HCC/HCF4009UB HCC/ HCF4010B
DYNAMIC ELECTRICAL CHARACTERISTICS (Tamb = 25 o C, C L = 50 pF, RL = 200 K, o typical temperature coefficent for all VDD values is 03 %/ C, all input rise and fall times= 20 ns)
Symbol tPLH Parameter Propagation Delay Time (4009UB) Test Conditions VDD (V) VI (V) VCC (V) 5 5 5 10 10 10 10 10 5 15 15 15 15 15 5 5 5 5 10 10 10 10 10 5 15 15 15 15 15 5 5 5 5 10 10 10 10 10 5 15 15 15 15 15 5 5 5 5 10 10 10 10 10 5 15 15 15 15 15 5 5 5 5 10 10 10 15 15 15 5 5 5 10 10 10 15 15 15 Min. Value Typ. 70 40 35 30 30 100 50 50 35 35 30 20 15 15 10 65 35 30 25 20 150 75 55 35 20 15 Max. 140 80 70 60 60 200 100 100 70 70 60 40 30 30 20 130 70 70 50 40 350 150 110 70 40 30 Unit
ns
tPLH
Propagation Delay Time (4010B)
ns
tPHL
Propagation Delay Time (4009UB)
ns
tPHL
Propagation Delay Time (4010B)
ns
tTLH
Transition Time
ns
tTHL
Transition Time
ns
Minimum and Maximum Voltage Transfer Characteristics for 4009UB
Typical Voltage Transfer Characteristics As a Function of Temperature for 4009UB
4/13
HCC/HCF4009UB HCC/HCF4010B
Minimum and Maximum Voltage Transfer Characteristics for 4010B Minimum and Maximum Voltage Transfer Characteristics for 4010B
Minimum and Maximum Voltage Transfer Characteristics for 4010B
Typical Voltage Transfer Characteristics As a Function ot Temperature for 4010B
Typical Output Los (sink) Current Characteristics
Minimum output Low (sink) Current Characteristics
5/13
HCC/HCF4009UB HCC/ HCF4010B
Typical Output High (source) Current Characteristics Minimum output High (source) Current Characteristics
Typical Low to High Propagation Delay Time vs Load Capacitance for 4009UB
Typical High to Low Propagation Delay Time vs Load Capacitance for 4009UB
Typical Low to High Propagation Delay Time vs Load Capacitance for 4010B
typical High to Low Propagation Delay Time vs Load Capacitance for 4010B
6/13
HCC/HCF4009UB HCC/HCF4010B
Typical Low to High Transition Time vs Load Capacitance Typical High to Low Transition Time vs Load Capacitance
Typical Dissipation Characteristics
7/13
HCC/HCF4009UB HCC/ HCF4010B
TEST CIRCUITS Quiescent Device Current. Noise Immunity.
Input Leakage Current.
8/13
HCC/HCF4009UB HCC/HCF4010B
Plastic DIP16 (0.25) MECHANICAL DATA
mm MIN. a1 B b b1 D E e e3 F I L Z 3.3 1.27 8.5 2.54 17.78 7.1 5.1 0.130 0.050 0.51 0.77 0.5 0.25 20 0.335 0.100 0.700 0.280 0.201 1.65 TYP. MAX. MIN. 0.020 0.030 0.020 0.010 0.787 0.065 inch TYP. MAX.
DIM.
P001C
9/13
HCC/HCF4009UB HCC/ HCF4010B
Ceramic DIP16/1 MECHANICAL DATA
mm MIN. A B D E e3 F G H L M N P Q 7.8 2.29 0.4 1.17 0.22 0.51 0.38 17.78 2.79 0.55 1.52 0.31 1.27 10.3 8.05 5.08 0.307 0.090 0.016 0.046 0.009 0.020 3.3 0.015 0.700 0.110 0.022 0.060 0.012 0.050 0.406 0.317 0.200 TYP. MAX. 20 7 0.130 MIN. inch TYP. MAX. 0.787 0.276
DIM.
P053D
10/13
HCC/HCF4009UB HCC/HCF4010B
SO16 (Narrow) MECHANICAL DATA
DIM. MIN. A a1 a2 b b1 C c1 D E e e3 F G L M S 3.8 4.6 0.5 9.8 5.8 1.27 8.89 4.0 5.3 1.27 0.62 8° (max.) 0.149 0.181 0.019 10 6.2 0.35 0.19 0.5 45° (typ.) 0.385 0.228 0.050 0.350 0.157 0.208 0.050 0.024 0.393 0.244 0.1 mm TYP. MAX. 1.75 0.2 1.65 0.46 0.25 0.013 0.007 0.019 0.004 MIN. inch TYP. MAX. 0.068 0.007 0.064 0.018 0.010
P013H
11/13
HCC/HCF4009UB HCC/ HCF4010B
PLCC20 MECHANICAL DATA
mm MIN. A B D d1 d2 E e e3 F G M M1 1.27 1.14 7.37 1.27 5.08 0.38 0.101 0.050 0.045 9.78 8.89 4.2 2.54 0.56 8.38 0.290 0.050 0.200 0.015 0.004 TYP. MAX. 10.03 9.04 4.57 MIN. 0.385 0.350 0.165 0.100 0.022 0.330 inch TYP. MAX. 0.395 0.356 0.180
DIM.
P027A
12/13
HCC/HCF4009UB HCC/HCF4010B
Information furnished is believed to be accurate and reliable. However, SGS-THOMSON Microelectronics assumes no responsability for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may results from its use. No license is granted by implication or otherwise under any patent or patent rights of SGS-THOMSON Microelectronics. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. SGS-THOMSON Microelectronics products are not authorized for use ascritical components in life support devices or systems without express written approval of SGS-THOMSON Microelectonics. © 1994 SGS-THOMSON Microelectronics - All Rights Reserved SGS-THOMSON Microelectronics GROUP OF COMPANIES Australia - Brazil - France - Germany - Hong Kong - Italy - Japan - Korea - Malaysia - Malta - Morocco - The Netherlands Singapore - Spain - Sweden - Switzerland - Taiwan - Thailand - United Kingdom - U.S.A