File name 4009.pdfHCC/HCF4009UB HCC/HCF4010B
HEX BUFFER/CONVERTERS
4009UBINVERTING TYPE 4010BNON INVERTING TYPE
. . . . . . . . .
CMOS TO DTL/TTL HEX CONVERTER HIGH-TO-LOW LEVEL LOGIC CONVERSION MULTIPLEXER: 1-TO-6 OR 6-TO-1 HIGH"SINK" AND "SOURCE" CURRENT CAPABILITY 5V, 10V AND 15V PARAMETRIC RATINGS MAXIMUM INPUT CURRENT OF 100 µA AT 18V OVER FULL PACKAGE AND TEMPERATURE RANGE; o 100nA AT 18V AND 25 C 100% TESTED FOR QUIESCENT CURRENT AT 20V MEETS ALL REQUIREMENTS OF JEDEC TENTATIVE STANDARD N. 13A, " STANDARD SPECIFICATIONS FOR DESCRIPTION OF B SERIES CMOS DEVICES "
non-inverting Hex Buffer/Converters, respectively. Both devices can be used as CMOS to TTL or DTL logic-level converters, as current "sink" or "source" drivers or as multiplexer (1 to 6). 4049UB and 4050B are prefered replacements for 4009UB and 4010B, respectively, in buffer applications.
EY (Plastic Package)
F (Ceramic Package)
DESCRIPTION The HCC4009UB/4010B (extended temperature range) and the HCF4009UB/4010B (intermediate temperature range) are monolithic integrated circuits available in 16-lead dual in line plastic or ceramic packages and plastic micropackage. The HCC/HCF4009UB/4010B are inverting and PIN CONNECTIONS 4009UB 4010B
M1 (Micro Package) C1 (Chip Carrier)
ORDER CODES : HCCXXXXBF HCFXXXXBM1 HCFXXXXBEY HCFXXXXBC1
September 1988
1/13
HCC/HCF4009UB HCC/ HCF4010B
SCHEMATIC DIAGRAM: COS/MOS TO DTL OR TTL CONVERTER (1 of 6 identical units)
4009UB
4010B
Connect VCC to DTL or TTL supply and VDD to COS/MOS supply
ABSOLUTE MAXIMUM RATING
Symbol VDD * Vi II Ptot Parameter Supply Voltage: HCC Types HCF Types Input Voltage DC Input Current (any one input) Total Power Dissipation (per package) Dissipation per Output Transistor for Top = Full Package Temperature Range Operating Temperature: HCC Types HCF Types Storage Temperature Value -0.5 to +20 -0.5 to +18 -0.5 to VDD + 0.5 ± 10 200 100 -55 to +125 -40 to +85 -65 to +150 Unit V V V mA mW mW
o o
Top Tstg
C C o C
Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress ratingonly and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for external periods may affect device reliability. * All voltage values are referred to VSS pin voltage.
RECOMMENDED OPERATING CONDITIONS
Symbol VDD VI Top Parameter Supply Voltage: HCC Types HCF Types Input Voltage Operating Temperature: HCC Types HCF Types Value 3 to 18 3 to 15 0 to VDD -55 to +125 -40 to +85 Unit V V V
o o
C C
2/13
HCC/HCF4009UB HCC/HCF4010B
STATIC ELECTRICAL CHARACTERISTICS (over recommended operating conditions)
Symbol IL Parameter Quiescent Current VI (V) Test Conditios VO |IO| VDD (V) (µA) (V) 5 10 15 20 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 5 5 10 15 5 5 10 15 5 10 15 5 10 15 18 Any Input Value TLOW * 25 oC Min. Max. Min. Typ. 1 0.02 2 0.02 |