Text preview for : 05ssi.pdf part of Nokia 2110 Nokia 2110 part2



Back to : Nokia_2110_2.zip | Home

After Sales Technical Documentation

NHE­1/3/4 SERVICE SOFTWARE INSTRUCTIONS

Original 11/97

Copyright E 1997 Nokia Mobile Phones. All rights reserved.

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

AMENDMENT RECORD SHEET
Amendment Number Date Inserted By Comments

Page 2

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

NHE­1/3/4 SERVICE SOFTWARE INSTRUCTIONS Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Minimum Required Servicing Equipment . . . . . . . . . . . . . . . . . Mechanical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Start Up Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to Service Software Package User Interface . . . . . Service Software/Hardware Enviroment . . . . . . . . . . . . . . . . . Service Software Enviroment . . . . . . . . . . . . . . . . . . . . . . . . . . Service Software Executables . . . . . . . . . . . . . . . . . . . . . . . Command Line Parameters . . . . . . . . . . . . . . . . . . . . . . . . . Common Properties of the User Interface . . . . . . . . . . . . . . . . . . Login Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Main Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dealer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Phone Identity Window . . . . . . . . . . . . . . . . . . . . . . . . . . . Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mouse Cursors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reserved Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Short Cut Function Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alt Hot Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ctrl Hot Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shift Hot Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Key Strokes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Help Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dialog boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Common Dialog boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Note Message Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Query Message Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Message Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Custom Dialog boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reporting Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6 Page 6 Page 6 Page 7 Page 8 Page 9 Page 9 Page 9 Page 10 Page 10 Page 11 Page 11 Page 12 Page 14 Page 14 Page 15 Page 15 Page 15 Page 16 Page 17 Page 17 Page 18 Page 18 Page 19 Page 19 Page 19 Page 19 Page 19 Page 20 Page 20 Page 21 Page 21 Page 22 Page 22 Page 22 Page 23 Page 24 Page 24 Page 25

Original 11/97

Page 3

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation Page 26 Page 26 Page 26 Page 26 Page 26 Page 27 Page 27 Page 27 Page 27 Page 27 Page 28 Page 29 Page 29 Page 30 Page 31 Page 32 Page 32 Page 33 Page 35 Page 37 Page 39 Page 42 Page 44 Page 45 Page 46 Page 46 Page 51 Page 56 Page 57 Page 59 Page 61 Page 62 Page 63 Page 65 Page 66 Page 67 Page 69 Page 69 Page 70 Page 71 Page 72 Page 73 Page 74 Page 75

NHE­1/3/4 Specific Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . New command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Open... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Close command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Initialize command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Local Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Faultlog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exit command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Options... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Directories... command . . . . . . . . . . . . . . . . . . . . . . . . . . . Faultlog... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AFC... command (NHE­4) . . . . . . . . . . . . . . . . . . . . . . . . AFC... command (NHE­1) . . . . . . . . . . . . . . . . . . . . . . . . RSSI (AGC)... command (NHE­4) . . . . . . . . . . . . . . . . . RSSI (AGC)... command (NHE­1) . . . . . . . . . . . . . . . . . TX Power... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . TX I/Q... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Battery A/D... command . . . . . . . . . . . . . . . . . . . . . . . . . . Charger A/D... command . . . . . . . . . . . . . . . . . . . . . . . . . Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick Testing (RF)... command (NHE­4) . . . . . . . . . . . . Quick Testing (RF)... command (NHE­1) . . . . . . . . . . . . Self Tests... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . MCU Powerup Self­tests . . . . . . . . . . . . . . . . . . . . . . . . . MCU Self Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ADC Readings... command (NHE­4) . . . . . . . . . . . . . . . ADC Readings... command (NHE­1) . . . . . . . . . . . . . . . Audio... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Display... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Call Simulation.. command . . . . . . . . . . . . . . . . . . . . . . . . Noise Sensitivity... command . . . . . . . . . . . . . . . . . . . . . . Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Phone Identity... command . . . . . . . . . . . . . . . . . . . . . . . . Serial Number Transfer... command . . . . . . . . . . . . . . . . Product Profile... command (NHE­4) . . . . . . . . . . . . . . . NHE­4 Product Profile Settings . . . . . . . . . . . . . . . . . . . . Product Profile... command (NHE­1) . . . . . . . . . . . . . . . NHE­1 Product Profile Settings . . . . . . . . . . . . . . . . . . . . Start Up Self­tests... command . . . . . . . . . . . . . . . . . . . .

Page 4

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4 Page 75 Page 76 Page 76 Page 78 Page 79 Page 80 Page 80 Page 80 Page 81 Page 82 Page 82 Page 82 Page 82 Page 82 Page 83 Page 84

Set Default Values... command . . . . . . . . . . . . . . . . . . . . Dealer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Short Code Memory... command . . . . . . . . . . . . . . . . . . . User Settings... command . . . . . . . . . . . . . . . . . . . . . . . . . Set UI Default Values... command . . . . . . . . . . . . . . . . . . View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick/RF Info... command (NHE­4) . . . . . . . . . . . . . . . . Quick/RF Info... command (NHE­1) . . . . . . . . . . . . . . . . Phone Identity... command . . . . . . . . . . . . . . . . . . . . . . . . Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General help command . . . . . . . . . . . . . . . . . . . . . . . . . . . Using Help command . . . . . . . . . . . . . . . . . . . . . . . . . . . . About... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Initialization File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix 1, Vocabulary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Original 11/97

Page 5

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

Introduction
General
The NHE­1/3/4 Service Software is specially designed to facilitate the servicing of GSM cellular telephones. The software can be used to control the phone according to the user's requirements merely by entering commands via the keyboard or mouse of a PC connected to the phone. This section refers to the Service Software Version 2.3. NMP After Sales will notify service personnel about future upgrades via Technical Bulletins. Software upgrades will be available from your local NMP outlet.

Minimum Required Servicing Equipment
­ Computer: Intel 386/33 MHz or compatible with one unused serial port (COM1 or COM2*), one parallel port (LPT1), hard disk recommended. ­ Memory: 4 MB or more ­ Operating System: DOS Version 5 & Microsoft Windows 3.11 or later ­ Display: VGA based display (640 x 480) ­ WinTesla Service Software: SWSA1 for 3.5" disk (product code: 0774046) ­ Software Protection Key PKD­1 (product code 0750018) ­ M2BUS interface cable DAU­2 (product code 0750006) ­ RS­232 adapter, 9 to 25 pins (product code 4626170) ­ Service cable SCS­1 (product code 0770010)

*) Note:

A number of PC's of an older generation use the Intel, National Semiconductor, or United Microelectronics IC 8250 as the serial port UART. This is a comparatively inefficient circuit for current purposes and does not necessarily support the M2BUS adapter at 9600 baud. The newer UART's NS16450 and NS16550AF of National Semiconductor offer solutions for these problems.

Page 6

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

Mechanical Connections
Caution: Ensure that you have switched off the PC and the printer before making connections ! Caution: Do not connect the PKD­1 to the serial port. This could damage the PKD­1 !
The software controls the phone via a separate adapter connected to the serial port of the PC and to the telephone's M2BUS (DAU­2 and SCS­1). Attach the protection key PKD­1 to parallel port one (25­pin female D­connector) of the PC. When connecting the PKD­1 to the parallel port be sure that you insert the PC end of the PKD­1 to the PC (male side). If you use a printer on parallel port one, place the PKD­1 between the PC and your printer cable. The PKD­1 should not effect devices working with it. If some errors occur (errors in printing are possible) please try printing without the PKD­1. If printing is OK without the PKD­1 please contact your dealer. We will offer you a new PKD­1 in exchange for your old one.

Original 11/97

Page 7

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

Attach first the RS­232 adapter cable to the PC's 9­pin serial port. Connect the M2BUS adapter (DAU­2) to the RS­232 cable. Connect the service cable SCS­1 to the M2BUS adapter (DAU­2) and attach the other end of the cable to the bottom connector of the phone.

Start Up Procedure
Start the phone by pressing the power­on button of the handset. Switch PC power on. To installing software, proceed as follows: 1. Insert Service Software disk into drive A of your PC 2. Start Windows: 3. Start Installing program: type WIN and press Enter select File ­> Run from Program Manager menu, then type A:INSTALL and press OK button

4. Follow Installation Software instructions

Page 8

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

Introduction to Service Software Package User Interface
This chapter gives a short description of the Service Software properties.

Service Software/Hardware Enviroment
To run the Service Software, a parallel port software protection device (PKD­1) has to be connected. The user can use the Service Software functions for testing all supported Phone Types. The functions send messages from the PC to the phone, receive results and show them on the PC display. The messages are sent via a low level NMP proprietary bus protocol. An example bus is an M2BUS interface, which needs M2BUS adapter (DAU­2) connected to the PC RS­232 port and special M2BUS cable.

The recommended minimum hardware standard to run the Service Software package is any computer which is 386 33Mhz or greater with at least 4 MB of memory and VGA type display (640x480). This assumes that only the Service Software package is active, i.e. other Windows packages are not running in the background. Note: if the Service Software is to be run on a laptop, the power saving feature MUST be switched off.

Service Software Enviroment
Service Software user interface is intended for Microsoft Windows 3.11 environment running in enhanced mode. For those who are familiar with Windows environment this application will be easy to use. Detailed information about Windows and application usage can be found from Ref 3­ Microsoft Windows Version 3.11 Users Guide chapter one (Windows Basics) and chapter two (Application Basics). As an ordinary Windows application, the main idea in the user interface is that selections are made with menus, push buttons and shortcut keys. Selections can be done by using keyboard and/or mouse. When messages from phone

Original 11/97

Page 9

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

are received, they cause display updating in special display windows. There is always a status bar displayed at the bottom of the main window which contains information about current actions.

Service Software Executables
Only one executable is needed ­ WinTesla. For NHE­1/3/4 there are two DLL's: ­ Functionality DLL is NH134.DLL ­ User Interface DLL is NH134EN.DLL

Command Line Parameters
There are NO command line parameters.

Page 10

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

Common Properties of the User Interface
This chapter describes how the User Interface CLF must appear to the user. The User Interface MUST be capable of being driven without the use of a mouse, as the service engineer rarely has space on the bench to use a mouse.

Login Dialog
When the Service Software application is invoked, by checking on the Service Software icon, the Login dialog box will be displayed on the screen.

Nokia logo and application name

Application version

Copyright version

Login box

Nokia logo and application name bitmap (­) Displays Nokia logo and name of the application. Application version static text (­) Contains the name and version of the application. Copyright notice static text (­) Copyright is informed as: "Nokia Mobile Phones (c) 1996. All Rights Reserved". Login Box edit box (­) The user Login ID edit box, where the user enters his faultlog user name. (See Faultlog User Guide) OK button (default key)

Original 11/97

Page 11

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

The user name is stored in memory and the dialog box is closed. When the dialog box is closed, the application starts. Cancel button (ESC) The Dialog box is closed and application is started, but the Faultlog feature is disabled. Help button (F1) Activates the Windows Help application and displays context sensitive Help.

Main Window
The application supports a Multiple Document Interface (MDI). However, the service software interface will present a Single Document Interface (SDI) appearance. Note: MDI is to allow for future expansion, e.g. R&D features.

Title bar The title bar is located at the top of the window. A title bar contains the following elements: · Application Control­menu button · Maximise button · Minimise button · Name of the application · Restore button The properties of these elements and their usage is described in Ref 3­ Microsoft Windows Version 3.11 Users Guide chapter one (Windows Basics) and chapter two (Application Basics). Menu bar The menu bar is below the title bar and contains all available menu selections. The menu bar is a dynamic element and is dependent on the dongle type fitted, and whether a phone is connected.

Page 12

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

Underlined characters in menu names and options indicates that the menu selection can be done by pressing Alt+ underlined character. Options can also be selected by activating menu bar with Alt­ key ( or F10 key ) and using arrow­keys to highlight the desired menu. In that case, selection is done by pressing Enter. Menus can also be selected by using the mouse as described in Ref 3­Microsoft Windows Version 3.11 Users Guide Status bar The status bar is displayed at the bottom of the Service Software main window. The status bar contains information about the menu selections and events. The left area of the status bar describes the actions of menu items as the user uses the arrow keys to navigate through menus. The status bar texts are explained in detailed in each of command's description. The right areas of the status bar indicate which of the following keys are latched down: Indicator USER CAP NUM SCRL Tool bar The tool bar is NOT defined and will not be implemented until specified by this document. Description Entered Login ID. The Caps Lock key is latched down. The Num Lock key is latched down. The Scroll Lock key is latched down.

Original 11/97

Page 13

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

Menu Bar
The Service Software package will have two menu bar configurations. The first, is an abbreviated version that contains the minimum number of menus that allows package configurations when a phone is NOT connected. The second is described below: The menu bar MUST only contain the follow menus for the Service Software package when a phone is connected: · Product* · Configure* · Tuning · Testing · Software · Dealer · View · Help* * ­ always displayed, even if no phone is connected. A menu is broken down into sections that are indicated with menu separators. Each sections identifies a logical difference from itself and other sections, i.e. between transmitter and receiver. Any items that are required to be added to a menu lists will be added on the bottom of the appropriate menu section list. If a new item is to be added which is common to two or more phone types, then that menu item will become a common menu item. The menu lists will use the Microsoft [...] symbol after an item name to indicate that selecting that item will NOT initiate an operation immediately, i.e. a dialog box will be displayed for the user to select options or type in data and press the OK button before the operation is performed.

Product
The Product menu contains the following menu items: · New · Open... · Close · Initialize ·Faultlog · Normal Mode · Local Mode F5 Shift+F5 Ctrl+R

· Activate Faultlog... F9 · Edit Faultlog... Alt+F4

· Exit

Page 14

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

Configure
The Configure menu contains the following menu items: · Options... · Directories... · Faultlog... · Phone Type Specific configuration items (where applicable)

Tuning
The Tuning menu contains the following menu sections: · Receiver · Transmitter · Voltages · Phone Type Specific tuning items (where applicable) An example Tuning menu is shown below: · AFC... · RSSI (AGC)... · Tx Power... · Tx I/Q... · Battery A/D · Charger A/D... Additional menu items may be added within the sections according to the phone type being tuned, e.g. a Charger tuning menu item will be added after the Battery tuning item, but not in the Transmitter tuning section.

Testing
The Testing menu contains the following menu sections: · Quick Tests · Digital · User Interface Flexi · Transmitter · Receiver · Automatic Tests · Phone Type Specific testing items (where applicable)

Original 11/97

Page 15

Service Software Instructions NHE­1/3/4 An example Testing menu is shown below: · Quick Testing (RF)... · Self Tests · ADC Readings · Audio · Display · Call Simulation... · Noise Sensitivity...

After Sales Technical Documentation

Additional menu items may be added within the sections according to the phone type being tested. Where a menu item consists of more than one test, a pop­up menu may be added to identify the appropriate sub­tests, e.g. there may be two receiver tests required for a particular phone type (Bit Error Rate and RSSI Monitoring). These will be shown as a popup from the Receiver menu item.

Software
The Software menu contains the following menu sections: · Phone Identity/Numbers · Flashing · Phone Type Specific software items (where applicable) An example Software menu is shown below: · Phone Identity · Serial Number Transfer... · Product Profile... · Start Up Self­tests... · Set Default Values

Page 16

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

Dealer
The Dealer menu contains the following menu sections: · Phone UI Data Editors · Phone UI Data Transfer · Phone Re­Initialization Functions · Subscriber Data · Phone Type Specific dealer items (where applicable) An example Dealer menu is shown below: · Short Code Memory · User Settings · Set UI/DEV Default Values ...

View
The View menu contains the following sections: · Service Windows · Production Windows (where applicable) · R&D Windows (where applicable) An example View menu is shown below: · Quick/RF Info... · Phone Information...

Original 11/97

Page 17

Service Software Instructions NHE­1/3/4 Phone Identity Window

After Sales Technical Documentation

The Phone Identity window should contain, as a minimum, the following data: · Software Version(s) · Hardware Version(s) · Serial Number(s) · Product Code This window will only be used as a display window and therefore will not allow editing of the displayed data. This window will not contain any controls other than a scroll bar.

Help
The Help menu contains the following menu items: · Index · General Help · Using Help · About WinTesla

Page 18

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

Mouse Cursors
The standards Windows pointer will be used as the mouse cursor. During time consuming tasks e.g. communication to phone, an hour glass will be shown informing the user that a task is in progress. The application uses the hour glass cursor to inform user that the application has taken the control and any actions from user will be ignored. When a function is initiated, the hour glass will be displayed and when the function has finished the mouse pointer will return to normal.

Reserved Keys
The following Hot keys and Short Cut keys are reserved either as Microsoft standard keys or as part of the Common Look and Feel specified by this document.

Short Cut Function Keys
Key F1 F5 Shift+F5 F9 F10 Ctrl+F4 Description Context Sensitive Help Normal Mode Local Mode Activate Faultlog Goto Menu Bar Close Active Window Defined by Microsoft NMP NMP NMP Microsoft Microsoft

Alt Hot Keys
Key Alt+F4 Alt+H Description Exit Active Application Help Defined by Microsoft Microsoft

Ctrl Hot Keys
Key Ctrl+N Ctrl+O Ctrl+P Ctrl+R Description File ­ New File ­ Open File ­ Print Product ­ New Defined by Microsoft Microsoft Microsoft NMP

Original 11/97

Page 19

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

Shift Hot Keys
Key Shift+F5 Description Local Mode Defined by NMP

Key Strokes
Key Alt+P Alt+P,N Alt+P,O Alt+P,C Alt+P,I Alt+P,I,N Alt+P,I,L Alt+P,F Alt+P,F,A Alt+P,F,E Alt+P,E Alt+C Alt+C,O Alt+C,D Alt+C,F Alt+T Alt+T,A Alt+T,R Alt+T,X Alt+T,Q Alt+T,B Alt+T,C Alt+E Alt+E,Q Alt+E,S Alt+E,A Alt+E,U Description Product Menu New Open Close Initialize Pop­up Normal Mode Local Mode Faultlog Pop­up Activate Faultlog Edit Faultlog Exit Application Configure Option Directories Faultlog Tuning Menu AFC RSSI(AGC) Tx Power Tx I/Q Battery Charger Testing Menu Quick Testing RF Self Tests ADC Readings Audio Defined by NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP

Page 20

Original 11/97

After Sales Technical Documentation Alt+E,D Alt+E,C Alt+E,N Alt+S Alt+S,I Alt+S,T Alt+S,P Alt+S,S Alt+S,V Alt+D Alt+D,C Alt+D,U Alt+D,V Alt+V Alt+V,Q Alt+V,P Alt+H Alt+H,I Alt+H,G Alt+H,U Alt+H,A Display Call Simulation Noise Sensitivity Software Menu Phone Identity Serial Number Transfer Product Profile Start­Up Self Tests Set Default Values Dealer Menu Short Code Memory User Settings Set UI Default Values View Menu Quick/RF Info Phone Information Help Menu Index General Help Using Help About WinTesla

Service Software Insructions NHE­1/3/4 NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP Microsoft Microsoft Microsoft Microsoft Microsoft

Help Functions
The Help User Interface will be the standard Windows help tool called WinHelp. The context sensitive help is activated with F1­key. Help contains also Using Help which describes how to use help facility. Refer to the Windows manual for detailed description on the Windows Help.

Dialog boxes
The Service Software application uses many different dialog boxes. Dialog boxes are used to display data and prompt the user for input. Dialog boxes are opened from menus or with shortcut keys. Dialog boxes have different properties but some features are common. All service dialog boxes must be modal, that is, the user will not be able to start another operation without first closing the present dialog box. All dialog boxes will contain the following entities:

Original 11/97

Page 21

Service Software Instructions NHE­1/3/4 ­ Help button ­ Title bar ­ At least one button other than Help ­ Application Control­menu Button

After Sales Technical Documentation

Common Dialog boxes
This sections describes the common dialog boxes used in the Service Software package, and the context in which they will be used. Note Message Box When the user has made an illegal selection, a note message box dialog will be opened and message text is displayed. The message box is also opened when the program has some information for the user. The size of the dialog box may vary. An information dialog box is recognized by the !­icon.

The dialog box will also contain an OK button and a Help button. OK button (default key): Acknowledge displayed information and continue. The dialog box is closed after selection. Help button (Alt+H): Opens context sensitive help as F1­key does. Query Message Box Confirmations and questions are asked in a query message box. A query dialog box is recognized by the ?­icon.

The dialog box will also contain a Yes button, a No button, and a Help button. Yes button (Alt+Y or Y) (default key): Accepts confirmation or question. No button (Alt+N or N): Denies confirmation or question. Help button (Alt+H): Opens context sensitive help as F1­key does. The buttons may also be OK and Cancel. The operation of these buttons are the same as in the Note dialog box.

Page 22

Original 11/97

After Sales Technical Documentation Error Message Box

Service Software Insructions NHE­1/3/4

Error message dialog boxes use the Stop­icon. When a "Stop"­dialog box is shown, the current operation is terminated. The dialog box has a description about the failed operation and reason. Pressing F1 (Help) application opens the appropriate help topic that gives information about recommended actions.

The dialog box will also contain an OK button and a Help button. OK button (default key): Acknowledges displayed information and terminate current operation. The dialog box is closed after selection. Help button (Alt+H): Open context sensitive help as F1­key does.

Original 11/97

Page 23

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

Custom Dialog boxes
All custom dialog boxes will contain the predefined buttons as defined below in the section ­ Buttons. However, it is recognised that features may require additional button types, but the addition of these non­standard buttons should be carefully considered to minimise any inconsistencies between implementations. The buttons will be positioned down the right­hand side of the dialog boxes. The default action will be OK, except where that default action could result in an irretrievable failure. All tuning dialogs that contain tuning results, will display the old tuned data read from the phone before the tuning was performed, as well as the newly tuned data. List boxes will be used to display lists of data, such as tuning data, test results etc. The use of Radio buttons should be limited and carefully considered. The use of radio buttons defines the number of possible choices available to the user, which may be acceptable for one project, but not for another.

Buttons
All buttons must be the Microsoft style of buttons. In general, the default button will be the OK button, the Close button or the Yes button, but this will depend on the context of the dialog box that the button is associated with. OK button: Accepts and validates entered settings and values and closes the dialog. If the values have not been changed, then no action will be taken. The status bar will reflect the status. The user should only be queried, if the settings or values accepted will over­write data that CAN NOT be reproduced. A greyed OK button indicates that settings selected by the user are not acceptable. Close button: Closes the current dialog box. Does not send or store anything and closes the dialog. The Close button is only used for dialogs that do not set or change any data. Cancel button (Esc): Cancel operation. Does not send or store anything and closes the dialog box. A greyed Cancel button indicates that it is not possible to quit from this dialog box.

Page 24

Original 11/97

After Sales Technical Documentation Yes button (ALT+Y or Y):

Service Software Insructions NHE­1/3/4

Replies Yes to a question asked of the user. No button (ALT+N or N): Replies No to a question asked of the user. Help button (ALT+H): Opens context sensitive help as F1­key does.

Reporting Status
The status bar will be used to report the present status to the user. When a feature is initiated, the status bar will be updated with a brief description of the function. The status bar will also be updated at key points in a time consuming function. If an error is to be reported to the user, it will be displayed in the status bar as well as displayed in a common error dialog box. This will mean the user is not delayed from progressing on to the next operation unless an error occurs, in which case, the user will have to acknowledge the error by pressing the OK button.

Original 11/97

Page 25

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

NHE­1/3/4 Specific Features
Menu Bar
The Service Software's menus adopts the menu structure specified by CLF.

Product
New command Activation Alt, P, N Ctrl+R Status Bar Text Rescan a new phone

This command scans a new product. When phone is found a product specific functionality module is loaded. If no phone or wrong phone/cellular type is detected, functionality is unloaded and user is informed. This function is also started automatically when the application is started. The user can also specify a regular poll which enables the WinTesla application to scan the new phone periodically. If the phone is still the same, no changes are done. If the phone is changed (with same phone type only the serial number is changed), the phone will be initialized to a normal mode. If the phone is changed to a different phone type, the current dlls are unloaded and new ones are loaded for that phone. The initialization routine checks the phone's cellular type (GSM/PCN), and if an unsupported phone is detected, the WinTesla application does not load the dlls. If quick info view is open, the window will be automatically updated. If phone identification view is open, the window will be automatically updated. Open... command Activation Alt, P, O Status Bar Text Force load phone specific functionality

Enables the user to force load specific phone's WinTesla dll's. It also disables further phone type detection with New command. Note: This selection is for applications that has reflashing functionality. Reflashing is not implemented for NH­1 phones.

Page 26

Original 11/97

After Sales Technical Documentation Close command Activation Alt, P, C Status Bar Text Close loaded functionality

Service Software Insructions NHE­1/3/4

Closes loaded functionality and sends reset to phone if dlls are loaded by Open command. Initialize command Activation Alt, P, I Status Bar Text ­

Opens a submenu which contains the following options: Normal Mode Activation Alt, P, I, N F5 Status Bar Text Initializes phone to normal mode

When normal mode has been activated or program has been started, self­test results will be asked from MCU. If any fault was found in the tests, an error message is shown. If normal mode has been set successfully (no self test error has been found), and paging listening has been started, the used AFC value is requested from MS. The Initialization routine checks the phone's cellular type (GSM/PCN) and if an unsupported phone is detected, the application unloads the dlls. If phone identification view is open, the window will be automatically updated. Also if RF Information Window is open it will be updated to quick info view. Local Mode Activation Alt, P, I, L Shift+F5 Status Bar Text Initialises phone to local mode

Selection will change the MS state to local. When local mode is selected the phone is controlled to the local mode so that special actions can be made (for example RF tunings). Faultlog Activation Alt, P, F Status Bar Text ­

Original 11/97

Page 27

Service Software Instructions NHE­1/3/4 Opens a submenu which contains following options: Activate Faultlog... Activation Alt, P, F, A F9 Edit Faultlog... Activation Alt, P, F, E Exit command Activation Alt, P, X Alt + F4 Double click the application's Control menu button: Status Bar Text Exit application Status Bar Text Activates faultlog editing Status Bar Text Activates faultlogging

After Sales Technical Documentation

This command ends the Service Software session.

Page 28

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

Configure
Options... command Activation Alt, C, O (Sample screen) Status Bar Text Edit Service Software configuration options

The Options dialog box contains the following items: Language drop down list. Current password edit box: New Password edit box: Retype Password edit box: User ID edit box. M2BUS Com Port drop down list. Automatic Rescan edit box. Units in seconds (eg. value10 checks the phone every 10 seconds in case it has been replaced). OK button (Alt+O): The dialog box is closed, and values are saved to phone.

Original 11/97

Page 29

Service Software Instructions NHE­1/3/4 Cancel button (Esc):

After Sales Technical Documentation

The dialog box is closed and changes are not saved to phone. Directories... command Activation Alt, C, D Status Bar Text Edit directory settings

The Directories dialog box contains the following items: ID Data edit box: Logs edit box: Fault log file(s) edit box: Data Validation file(s) edit box: Flash Images edit box: Blow failures edit box: OK button (Alt+O): The dialog box is closed, and values are saved to phone. Cancel button (Esc): The dialog box is closed and changes are not saved to phone.

Page 30

Original 11/97

After Sales Technical Documentation Faultlog... command Activation Alt, C, F Status Bar Text Edit faultlog settings

Service Software Insructions NHE­1/3/4

The Faultlog dialog box contains the following items: Fault log enabled/disabled radio buttons: Allow Manual Entry enabled/disabled radio buttons: Automatic fault log prompting enabled 1/Disabled 2 radio buttons: Station identity edit box: Country of Repair edit box: Warranty period months edit box / drop down list: Maximum Time to repair edit box:

Original 11/97

Page 31

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

Tuning
The tuning menu offers functions for ME adjustments. AFC... command (NHE­4) Activation Alt, T, A Starts AFC tuning. The following are automatically selected when this tuning function is activated: Active Unit = RX Operation mode = Continuous Update RF Information window Before tuning is started, the user is requested to set signal generator to specified input level (read from .INI file). Status Bar Text Open an AFC diagram dialog box

The AFC Diagram dialog box will open when user accepts request:

The AFC Diagram dialog box contains the following items: Repeat button (Alt+R): The measurement can be started again by pressing Repeat button. OK button (Alt+O): The dialog box is closed, and tuning is saved to phone.

Page 32

Original 11/97

After Sales Technical Documentation Cancel button (Esc):

Service Software Insructions NHE­1/3/4

Dialog is closed and tuning is not saved to phone. The D/A converter range (DAC) is from +1023 to ­1024 and voltage range is from 0.3 V to 3.9 V (voltage precision is 0.01 V). The frequency error range is from ­134 kHz to +134 kHz with the precision 0.1 kHz. The rounding is made to the closest value. After exiting with the Cancel button, the following are reset to the values which were selected before this adjustment. Active Unit Operation mode Update RF Information window The AFC is also reset to its previous value after exiting with the Cancel button. AFC... command (NHE­1) Activation Alt, T, A Starts AFC tuning. The following are automatically selected when this tuning function is activated: Active Unit = RX Operation mode = Continuous Update RF Information window Before tuning is started, the user is requested to set signal generator to specified input level (read from .INI file). Status Bar Text Open an AFC diagram dialog box

The AFC Diagram dialog box will open when user accepts request:

Original 11/97

Page 33

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

(Sample screen)

The AFC Diagram dialog box contains the following items: Repeat button (Alt+R): The measurement can be started again by pressing Repeat button. OK button (Alt+O): The dialog box is closed, and tuning is saved to phone. Cancel button (Esc): Dialog is closed and tuning is not saved to phone. The frequency error precision is 0.1 kHz. The rounding is made to the closest value. After exiting with the Cancel button, the following are reset to the values which were selected before this adjustment. Active Unit Operation mode Update RF Information window The AFC is also set to the middle (zero) value after exiting with the Cancel button.

Page 34

Original 11/97

After Sales Technical Documentation RSSI (AGC)... command (NHE­4) Activation Alt, T, R Status Bar Text

Service Software Insructions NHE­1/3/4

Open RSSI Calibration dialog box

Starts RSSI calibration. The following are automatically selected when this tuning function is activated: Active Unit = RX Operation Mode = Continuous Update RF Information window The measurement is started automatically when RSSI calibration is entered. The measurement is done in five steps: 1. The user is requested to set signal generator to low input level (read from .INI file).

2. Measurement with low input level is executed. 3. The user is requested to set signal generator to high input level (read from .INI file).

4. Measurement with high input level is executed.

Original 11/97

Page 35

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

5. The RSSI Calibration dialog box will be updated when previous steps are done. (Sample screen)

The RSSI Calibration dialog box contains the following items: AGC List box (Alt+A): Gain code DAC can have values from 0 to 1023 and voltage from 0.26 V to 3.86 V (voltage precision is 0.01 V). Note that the needed input signal level is also shown. The difference column shows the difference between tuned DAC values and mean straight line calculated from part slopes in dBs (see /1/). This can be calculated when all measurement results have been received from phone. Repeat button (Alt+R): The measurement can be started again by pressing this button. OK button (Alt+O): The dialog box is closed, and tuning is saved to phone. Cancel button (Esc): The dialog box is closed and tuning is not saved to phone.

Page 36

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

When calibration is ended, the DAC value check is made, and if it is unsuccessful, an error message is shown. The test checks if all DAC values are in the same order as AGC values in the table. After exiting with the Cancel button, the following are reset to the values which were selected before this adjustment. Active Unit Operation Mode Update RF Information window The exit and the use of AGC­control values is done the same way as exit from power level tuning and power coefficient use.

RSSI (AGC)... command (NHE­1) Activation Alt, T, R Status Bar Text Open RSSI Calibration dialog box

Starts RSSI calibration. The following are automatically selected when this tuning function is activated: Active Unit = RX Operation Mode = Continuous Update RF Information window The measurement is started automatically when RSSI calibration is entered. The measurement is done in three steps: 1. The user is requested to set signal generator to low input level (read from .INI file).

2. Measurement with low input level is executed. 3. The RSSI Calibration dialog box will be updated when previous steps are done.

Original 11/97

Page 37

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

(Sample screen)

The RSSI Calibration dialog box contains the following items: RSSI Offset value: RSSI offset value has the 0.1 dB precision. AGC List box (Alt+A): AGC list box shows gain code values and correspondence compensation term values. AGC compensation terms have the 0.1 dB precision. Repeat button (Alt+R): The measurement can be started again by pressing this button. OK button (Alt+O): The dialog box is closed, and tuning is saved to phone. Cancel button (Esc): The dialog box is closed and tuning is not saved to phone. After exiting with the Cancel button, the following are reset to the values which were selected before this adjustment. Active Unit Operation Mode Update RF Information window

Page 38

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

The exit and the use of AGC­control values is done the same way as exit from power level tuning and power coefficient use. TX Power... command Activation Alt, T, X Status Bar Text Open TX Power Tuning dialog box

Starts TX power tuning. The user is first requested to select with which values tuning is started in the Start Tuning dialog box.

The Start Tuning dialog box contains the following items: Start Tuning With list box (Alt+S): Current Values in PC memory Tuning values are loaded from the program's internal memory. EEPROM Values Tuning values are loaded from ME's EEPROM. The following are automatically selected when this tuning function is activated: ­ Active Unit = TX ­ the BASE power level is selected ­ Operation mode = Burst

Original 11/97

Page 39

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

The TX Power Tuning dialog box will be activated automatically after value selection. NHE­4 dialog box: (Sample screen)

NHE­1 dialog box: (Sample screen)

The TX Power Tuning dialog box contains the following items: Power Level & Coefficients list box (Alt+P): The power is presented in GSM values (5..15). The base power is selected automatically when the dialog box is opened. The test value is reset to 0.035 when the program is started. The test value is not saved to the EEPROM. The test value can be changed during tuning

Page 40

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

as other power coefficients and the program remembers its value when tuning function is activated later again. If there are more power levels in the phone than can fit into the window, the window is scrollable. When the phone is initialized, the program asks the number of power levels used in the phone. Only three power coefficients (biggest, third smallest and smallest) are needed to tune and the rest of them are calculated. The tuning position is highlighted and can be tuned with +/­ keys or left/right cursor keys. Calculate button (Alt+C): The calculation is activated with this button. The power coefficients which are calculated from the tuned coefficients are displayed on the different columns than the others. All values can be tuned if needed. +/­ buttons (+/­): The + and ­ buttons will cause power changing by 0.25dB steps (D/A converter control value ratio is 1.0292). When these keys are used, the coefficient value is updated on the tuning window. OK button (Enter): The dialog box is closed, and tuning is saved to phone. Cancel button (Esc): The dialog box is closed, and tuning is not saved to phone. When selections are used, the power value checking is made and if it is unsuccessful, an error message is shown. The test checks that all power coefficients are in descending order (same order as power levels). If the power tuning function is ended and EEPROM values are not received or EEPROM fault is noticed, an error message is shown. When all power coefficients have such values that they don't cause any error messages, the dialog box will close. The last selected tuning power will be used after exit. Because the stored power level range is larger than the number of used power levels, the unused levels should be set to nearest possible power level. (For example in GSM the levels 2­4 are not used, so they are set to same value as level 5). When this tuning function is ended, the following is automatically selected: Active Unit = RX

Original 11/97

Page 41

Service Software Instructions NHE­1/3/4 TX I/Q... command Activation Alt, T, Q Status Bar Text Open the TX I/Q Tuning dialog box

After Sales Technical Documentation

This function is used for tuning TX I and Q branch DC offset, amplitude difference and phase difference. The function opens the same Start Tuning dialog box as with TX Power Tuning. When this function is activated the following are automatically selected: Active Unit = TX Operation Mode = Burst TX Power Level = 10 If TX Data Type = RANDOM => TX Data Type = 1 Update RF Information window

Page 42

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

The TX I/Q Tuning dialog box is opened. (Sample screen)

The TX I/Q Tuning dialog box contains the following items: Tune TX I DC Offset scroll bar (Alt+I): The DC Offset is shown in percent (%) from the ± maximum value. 0% means that there is no DC. The value range is ­100%...100%. The value is rounded to the nearest integer value. Tune TX Q DC Offset scroll bar (Alt+Q): The operation of this function is the same as one above, except with this selection the Q branch DC Offset is tuned. The value range is ­100%...100%. The value is rounded to the nearest integer value. Tune Amplitude Difference scroll bar (Alt+A): When this selection is made, the user can increase or decrease the amplitude difference in 0.1 dB steps. The value range is ­1...1. Tune Phase Difference scroll bar (Alt+P): When this selection is made, the user can increase or decrease the phase difference in 0.5° steps. The current phase difference is shown in the tuning window with numbers and bar figure. The value range is 85...95. OK button (Enter): The dialog box is closed, and tuning is saved to phone. Cancel button (Esc): The dialog box is closed, and tuning is not saved to phone. After each value change, the new value is sent to the phone. The following will be automatically selected when the TX I / Q tuning function is ended: Active Unit = RX Update RF Information window

Original 11/97

Page 43

Service Software Instructions NHE­1/3/4 Battery A/D... command Activation Alt, T, B Status Bar Text Calibrate battery voltage

After Sales Technical Documentation

This function is for battery a/d tuning. Before battery a/d tuning is started, a voltage setting request is shown to the user:

When an external power is connected, and the user selects OK to continue, the application measures a/d converter and displays the Battery A/D Calibration dialog box.

The Battery A/D Calibration dialog box contains the following items: Repeat button (Alt+R): Makes measurement again. OK button (Enter): The dialog box is closed, and tuning is saved to phone. Cancel button (Esc): The dialog box is closed, and tuning is not saved to phone.

Page 44

Original 11/97

After Sales Technical Documentation Charger A/D... command Activation Alt, T, C Status Bar Text Calibrate charger voltage

Service Software Insructions NHE­1/3/4

Works in the same way as the previous Battery A/D calibration.

Original 11/97

Page 45

Service Software Instructions NHE­1/3/4

After Sales Technical Documentation

Testing
The Testing sub menu offers functions for ME testing. Quick Testing (RF)... command (NHE­4) Activation Alt, E, Q Status Bar Text Open the Quick Testing dialog box

This function is used for quick RF testing. The command opens the Quick Testing dialog box, which contains data for testing and adjustments. (Sample screen)

The Quick Testing dialog box contains the following items: Active Unit group: RX radio button (Alt+R): When RX is selected, the next functions are made: Data transmission is deactivated

Page 46

Original 11/97

After Sales Technical Documentation TX power is deactivated If operation mode is continuous, ­ AGC is controlled

Service Software Insructions NHE­1/3/4

­ RX continuous mode channel is activated If operation mode is burst, ­ RX and Monitoring channels are activated RF Information window is updated The RX value is always given as default. Note! The function is activated immediately, Apply is not needed. TX radio button (Alt+T): When TX is selected, the next functions are made: Data transmission is activated Operation mode is set to burst, TX power is activated RF Information window is updated Note! The function is activated immediately, Apply is not needed. Operation Mode group: Continuous radio button (Alt+C): When continuous selection is used, Synthesiser is set to constant frequency Synthesiser channel number is as given with Continuous Mode Channel selection Transmitter power is not connected Note! The function is activated immediately, Apply is not needed. Burst radio button (Alt+B): When burst selection is used, the synthesiser is controlled by using GSM/PCN receiving/transmission/measuring synthesiser. Control sequence synthesiser channel numbers are as given with Channel/Monitoring Channel selections. If Active Unit is TX, data (selected with TX Data Type) is sent, and the TX power is connected Note! The function is activated immediately, Apply is not needed.

Original 11/97

Page 47

Service Software Instructions NHE­1/3/4 TX Data Type drop list (Alt+D):

After Sales Technical Documentation

This list changes the transmission data type. The list consists of the following options: 0, 1, and Random. After Random, data selection 0 is used. If Operating Mode is continuous, TX Data Type Random causes different data sending than in burst mode. TX Power Level edit box (Alt+X): With this value it is possible to change the transmission power. The user can give the needed GSM/PCN power value (5..15/0...10) or select the TEST or BASE. These values is found at the end of the list. Channel edit box (Alt+N): The user can enter here the channel number that is used for both transmission and receiving. The frequency of the selected channel is shown after selection. Monitoring Channel edit box (Alt+M): This field selects neighbouring monitoring channel. The frequency of the selected channel is shown after selection. Continuous Mode Channel edit box (Alt+O): To this edit box the user can type the continuous mode channel which may have all GSM channel numbers (1..124) or PCN channel numbers (512...885). The used frequency depends on the Active Unit. If the Active Unit is RX, then RX frequency is used, else TX frequency. The frequency of the selected channel is shown after selection. AGC edit box (Alt+G): This selection allows user to edit the AGC absolute value (value from A/D converter). The AGC can have values from 0dB to 93dB in 3dB steps in GSM, and from 0dB to 81dB in PCN. The AGC value is shown only when its value is controlled by the PC. When the Active Unit has value RX and Operation Mode is continuous, AGC is controlled by the PC except when next adjustment functions are activated: RSSI Calibration AFC Diagram AFC edit box (Alt+F): This selection allows the user to edit the AFC D/A converter value. The AFC can have values from ­1024 to 1023.

Page 48

Original 11/97

After Sales Technical Documentation

Service Software Insructions NHE­1/3/4

The AFC value is the last measured AFC D/A converter value (11 bit 2­complement value is used with decimal digits). If the AFC results are not received, no text is shown. The AFC value is neither shown in the next situations i.e. when AFC is not controlled by PC: AFC Diagram Apply button (Alt+A): Accepts entered values and validates them. After validation, the application sends corresponding messages to ME. Closes the dialog box, and updates Info Window. Note: Active Unit and Operation mode command do not use the Apply button, as they are activated immediately. Following automatic selections are made when Quick testing function is ended. Active Unit = RX Update RF Information window Set Defaults button (ALT+S): Sets current values as default Quick Test values. Get Defaults button (ALT+E): Gets default Quick Test values as current values.

The next table shows the dialog box's properties in different situations: ACTIVE UNIT = TX: TX Data Type: Updated AGC values: Greyed Monitoring Channel: Greyed OPERATION MODE = BURST: TX Power Level: Updated Continuous Mode Channel: Greyed Channel: Updated OPERATION MODE = CONT.: TX Power Level: OFF, Greyed Continuous Mode Channel: Updated Channel: Greyed

Original 11/97

Page 49

Service Software Instructions NHE­1/3/4 ACTIVE UNIT = RX: TX Data Type: Greyed TX Power Level: OFF, Greyed OPERATION MODE = BURST: AGC values: Greyed AFC values: Greyed Continuous Mode Channel: Greyed Channel: Updated Monitoring Channel: Updated OPERATION MODE = CONT: AGC values: Updated AFC values: Updated Continuous Mode Channel: Updated Channel: Greyed Monitoring Channel: Greyed

After Sales Technical Documentation

Page 50

Original 11/97

After Sales Technical Documentation Quick Testing (RF)... command (NHE­1) Activation Alt, E, Q Status Bar Text

Service Software Insructions NHE­1/3/4

Open the Quick Testing dialog box

This function is used for quick RF testing. The command opens the Quick Testing dialog box, which contains data for testing and adjustments. (Sample screen)

The Quick Testing dialog box contains the following items: Active Unit group: RX radio button (Alt+R): When RX is selected, the next functions are made: Data transmission is deactivated TX power is deactivated If operation mode is continuous,

Original 11/97

Page 51

Service Software Instructions NHE­1/3/4 ­ AGC is controlled ­ RX continuous mode channel is activated RF Information window is updated The RX value is always given as default. Note! The function is activated immediately, Apply is not needed. TX radio button (Alt+T): When TX is selected, the next functions are made: Data transmission is activated

After Sales Technical Documentation

If operation mode is continuos, TX continuos mode channel is activated If operation mode is burst, TX power is activated RF Information window is updated Note! The function is activated immediately, Apply is not needed. Operation Mode group: Continuous radio button (Alt+C): When continuous selection is used, Synthesiser is set to constant frequency Synthesiser channel number is as given with Continuous Mode Channel selection If Active Unit is TX, data (selected with TX Data Type) is sent Transmitter power is not connected If Active Unit is RX, AGC is controlled Note! The function is activated immediately, Apply is not needed. Burst radio button (Alt+B): When burst selection is used, the synthesiser is controlled by using GSM/PCN receiving/transmission/measuring synthesiser. Control sequence synthesiser channel numbers are as given with Channel/Monitoring Channel selections. If Active Unit is TX, data (selected with TX Data Type) is sent, and the TX power is connected Note! The function is activated immediately, Apply is not needed.

Page 52

Original 11/97

After Sales Technical Documentation TX Data Type drop list (Alt+D):

Service Software Insructions NHE­1/3/4

This list changes the transmission data type. The list consists of the following options: 0, 1, and Random. After Random, data selection 0 is used. If Operating Mode is continuous, TX Data Type Random causes different data sending than in burst mode. TX Power Level edit box (Alt+X): With this value it is possible to change the transmission power. The user can give the needed GSM/PCN power value (5..15/0...10) or select the test value, which is tuned with theTX power tuning function. The test value is found at the end of the list. TX Power have value OFF and is disabled (greyed) when active unit is RX or transmission power as GSM or PCN value. When the TX power is tuned with test value (smallest value) the TX Power has value TEST. Channel edit box (Alt+N): The user can enter here the channel number that is used for both transmission and receiving. The frequency of the selected channel is shown after selection. Monitoring Channel edit box (Alt+M): This field selects neighbouring monitoring channel. The frequency of the selected channel is shown after selection. Continuous Mode Channel edit box (Alt+O): To this edit box the user can type the continuous mode channel which may have all GSM channel numbers (1..124) or PCN channel numbers (512...885). The used frequency depends on the Active Unit. If the Active Unit is RX, then RX frequency is used, else TX frequency. The frequency of the selected channel is shown after selection. AGC edit box (Alt+G): This selection allows user to edit the AGC absolute value (value from A/D converter). The AGC can have values from 0dB to 93dB in 3dB steps in GSM, and from 0dB to 81dB in PCN. The AGC value is shown only when its value is controlled by the PC. When the Active Unit has value RX and Operation Mode is continuous, AGC is controlled by the PC except when next adjustment functions are activated: RSSI Calibration AFC Diagram

Original 11/97

Page 53

Service Software Instructions NHE­1/3/4 Apply button (Alt+A):

After Sales Technical Documentation

Accepts entered values and validates them. After validation, the application sends corresponding messages to ME. Closes the dialog box, and updates Info Window. Note: Active Unit and Operation mode command do not use the Apply button, as they are activated immediately. Following automatic selections are made when Quick testing function is ended. Active Unit = RX Update RF Information window Set Defaults button (ALT+S): Sets current values as default Quick Test values. Get Defaults button (ALT+E): Gets default Quick Test values as current values.

The next table shows the dialog box's properties in different situations: ACTIVE UNIT = TX: TX Data Type: Updated AGC values: Greyed Monitoring Channel: Greyed OPERATION MODE = BURST: TX Power Level: Updated Continuous Mode Channel: Greyed Channel: Updated OPERATION MODE = CONT.: TX Power Level: OFF, Greyed Continuous Mode Channel: Updated Channel: Greyed ACTIVE UNIT = RX: TX Data Type: Greyed TX Power Level: OFF, Greyed OPERATION MODE = BURST:

Page 54

Original 11/97

After Sales Technical Documentation AGC values: Greyed

Service Software Insructions NHE­1/3/4

Continuous Mode Channel: Greyed Channel: Updated Monitoring Channel: Updated OPERATION MODE = CONT: AGC values: Updated Continuous Mode Channel: Updated Channel: Greyed Monitoring Channel: Greyed

Original 11/97

Page 55

Service Software Instructions NHE­1/3/4 Self Tests... command Activation Alt, E, S Status Bar Text Open MCU Self­tests dialog box

After Sales Technical Documentation

The command is used for reading self test results and running self tests. User is first requested to run self­tests in minimum mode, or to look powerup self­tests results with Test Type Selection dialog.

The Test Type Selection dialog has following items: Test Type list box (ALT+S): Power up self­test results Shows power up self­test results in MCU Powerup Self­tests dialog. Run Self­tests in minimum mode Sets phone to minimum mode and opens MCU Self­tests dialog.

Page 56

Original 11/97

After Sales Technical Documentation MCU Powerup Self­tests

Service Software Insructions NHE­1/3/4

When powerup self­tests are selected the test results are read from the phone and displayed in MCU Powerup Self­tests dialog. (Sample screen)

The MCU Powerup Self­tests dialog has following items: When powerup self­tests are selected test results are read from phone and displayed in MCU Self­tests dialog. Tests list box (ALT+T): Test states are updated according to the results received from the phone. Possible test states will be one of the next:

Passed Failed No response Not executed
Only on the fault value is indicated in the DSP self­test message. Note that DSP test results can be asked from DSP only when all MCU tests have been passed. Possible DSP error texts are:

RAM BUS Fault, ASIC BUS Fault, RFI BUS Fault, Unknown and Download Error.

Original 11/97

Page 57

Service Software Instructions NHE­1/3/4 Bus Errors... button (ALT+B):

After Sales Technical Documentation

When this selection is made Bus Test dialog is displayed. In this dialog are shown results from the first failed MCU BUS test. When none of MCU BUS tests has been failed this selection is disabled (greyed). The field "(s)" means that this test is selectable one. The following tests are available: MCU Internal Test................: MCU RAM BUS Test.................: MCU IMEI Test....................: MCU ROM BUS Test.................: MCU ROM Data Test................: MCU ASIC BUS Test.............(s): MCU ASIC Timer and IRQX Test..(s): MCU ASIC Timer and NMI Test...(s): MCU Audio Codec Test..........(s): MCU DSP Code Download Test.......: MCU EEPROM Checksum Test.........: Sim­Lock Checksum Test...........: DSP Tests........................:

Page 58

Original 11/97

After Sales Technical Documentation MCU Self Tests

Service Software Insructions NHE­1/3/4

When the selection is made, the test result is read from ME. The test result will be shown to the user within the MCU Self­test dialog box. (Sample screen)

The MCU Self­test dialog box contains the following items: Tests list box (Alt+T): The field "(p)" in the screen example means that the test is also run in power up. The field "/s)" means that this test is selectable one. Test states are updated according to the results received from the phone. Possible test states will be one of the following:

Passed Failed No response Not executed RUNNING....
Run button (Alt+R): The user can select desired test from list and hit Run button. When user selects test to be run, the text RUNNING... is shown in the test state field, and test is run. When results are received, the test state field is updated according to the result. If no response was received in the defined time, a error message box will be shown and the test state is changed to No response.

Original 11/97

Page 59

Service Software Instructions NHE­1/3/4 Bus Errors... button (ALT+B):

After Sales Technical Documentation

When this selection is made Bus Test dialog is displaye