Installation

1. Installation of indoor, Outdoor unit

1) Select the best location * Both gas and liquid interconnecting pipes must be
1. Indoor unit insulated as a pair, but it is not necessary to
individually insulate them.
Do not have any heat or steam near the unit.
Select a place where there are no obstacles in
front of the unit. 2) Piping length and elevation
Make sure that condensation drainage can be
conveniently routed away. Pipe Size Standard Max. Max. Additional
Do not install near a doorway. Capacity Length Elevation length Refrigerant
Ensure that the space around the left and right of (Btu/h) GAS LIQUID (m) B (m) A (m) (g/m)
the unit is more than 5cm. The unit should be
installed as high on the wall as possible, allowing 9K, 12K 1/2" 1/4" 5 7 15 20
a minimum of 5cm from ceiling.
Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
Outdoor unit

More than 5cm More than 5cm


A

More than 2.3m Indoor unit B
More than 5cm

CAUTION
Install the indoor unit on the wall where the height
from the floors more than 2.3 meters.

2. Outdoor unit
If an awning is built over the unit to prevent direct Outdoor unit
sunlight or rain exposure, make sure that heat
radiation from the condenser is not restricted.
Ensure that the space around the back and sides
A
is more than 10cm. The front of the unit should Oil trap
have more than 70cm of space.
Do not place animals and plants in the path of the Indoor unit
warm air. B
Take the air conditioner weight into account and
select a place where noise and vibration are
minimum.
Select a place so that the warm air and noise
from the air conditioner do not disturb neighbors.
In case more than 5m

More than 60cm

More than 10cm More than 10cm

CAUTION