Text preview for : cellesse_©_.pdf part of Philips HP5230 Service Manual Cellesse 8W 99/02 - pag. 4
Back to : cellesse_©_.pdf | Home
Cellesse HP 5230 Beige / Brown HP 5230 Beige / Green
Philips Domestic Appliances and Personal Care
Service manual 4822 729 21748 is herewith cancelled
PRODUCT INFORMATION Type appliance Voltage (mains) : 12 V adapter from mains (AC/DC) : 220-240 V, 50/60 Hz 110-127 V, 50/60 Hz : DC type
Introduction The Cellesse is a special massage system, designed to help reduce or prevent the unsightly appearance of cellulite. Cellulite is the increased visibility of lumpy fat deposits through the surface of the skin. A common used description is `orange peel skin' because of its unique pitted, lumpy appearance. Cellulite should not be confused with "cellulitis", which is a medical term linked to bacterial infection of the skin. Cellulite can be reduced with the help of this product. It can never be completely eliminated and will return when neglected. A maximum reduction of the Cellulite layer by 55 % can be reached after 3 months, if the appliance is used 3 times a week for 15 mins. on each leg. The Cellesse does not reduce the fat in the fat layer.
Motor
Max. powerconsumption : 8 watts Under pressure Length cord : 5 steps from 80 mbar to 250 mbar : 2.5 m
Note: Product meets the requirements regarding interference suppression on radio and TV.
Published by Philips Domestic Appliances and Personal Care
Printed in the Netherlands
© Copyright reserved
Subject to modification
4822 729 22124 99/02
PCS 101 214
FUNCTIONAL DESCRIPTION OF THE HP5230 CELLESSE Function of the Cellesse The product is connected to the mains and the ON/OFF switch ( A ) is set to level 1 - 5. The pump ( B ) starts to function. The pump ( B ) only starts to function if the appliance is in a proper contact with the skin so a vacuum of at least 80 mbar can be reached. Once a vacuum of 80 mbar is reached, the electronic suppression switch ( C ) switches on the motor ( D ) of the massage rolls ( E ). To avoid a painful sucking in of the skin, the vacuum stop buttons ( F ) can be operated so that the vacuum is eliminated. The Cellesse only functions properly if the product is put properly on the skin so that the pump can build up a vacuum in the sucking area.( G ) Cleaning and Maintenance Never immerse the appliance in water nor rinse it. For the best results, keep the Cellesse clean at all times, using a damp cloth and a spot of detergent, if necessary. Do not use alcohol, acetone, gasoline, abrasives, scourers and so on for cleaning the appliance. When cleaning, special attention should be paid to the rollers on the underside. Cleaning the rollers
To clean the rollers select Level 1
Fig. 1
Cover the suction opening with your thumb so the rollers start to rotate.
Fig. 2
Wipe the rollers clean with a damp cloth.
Fig. 3
OLD
VACU-stop Button F On/off Switch + Suppression Switch Level 1-5 Sleeve 105 El. Suppression Switch C Switches on the motor D automatically at 80 mBar underpressure Sleeves Pump B
A1 P-JACK W1 blue C24 1 not on PCB A2 R31 W3 red C1 R1 Q1 R2 R3 R25 R5 C2 R6 D1 W4 red W6 red
M
M1
D3
M
M2
A Sleeve 104
P
W2 red R30
A3 Q22 Q2
W5 blue
W7 blue
R24
Q3 R4 Q21 R22 M1 = Motor rolls M2 = Pump R27 3 Q20a 2 R29 7 R32 R28 C23 4 C21 D20
DAP0306
R26 8 Q20b 6 5
C20
R21
R20
NEW
+13V TP6 not on W1_1 PCB C3 R1 Q1 A3 TP7 A4 TP11 not on W5 PCB red TP13 not on W7 PCB red
not on W4 PCB red
Sucking Area G Rolls E
SOCKET-PCB
red W3 TP5 W1_2 TP4 TP3
R2
R3 W1_2 LEDPCB not on W3_1 PCB blue W6 TP8 TP12 blue W8 TP14
M
M1
M
M2
W9_1
P
A1 P-JACK TP1 TP2 W1_1
A3
D3 TP9
A5
W3_2 TP10 W9_2
R4
TP15 Q2 C4 R5
DAP0777
PCS 101 215
EXPLODED VIEW + PARTS LIST
T
101 103 13 7
A 1
1 6 D 10 A 102 104 5 8 D C 2
g
A d o t t
B
B C 9
12
105
4
11
PARTS LIST
Pos Descprition 1 2 4 5 6 7 8 9 10 11 12 set housing parts, consisting of items 101, 102 and 2 (3x) screw power unit pump vacuum control unit - on/off switch vacuum stop p.c.b. set tubes ( item 104 + 105 ) decorative ring filter adapter EURO 220-240 V adapter UK 220-240 V
Service code Beige/Brown Beige/Green 4822 310 10948 4822 502 14427 4822 310 10949 4822 310 10951 4822 310 10952 4822 310 10953 4822 310 10954 4822 310 10955 4822 466 11484 4822 480 10164 4822 219 10047 4822 219 10202 4822 310 11359 4822 502 14427 4822 310 11361 4822 310 11362 4822 310 11363 4822 310 11364 4822 310 11365 4822 310 11366 4822 310 12242 4822 480 10272 4822 219 10618 4822 219 10619
Pos Descprition 12 adapter adapter adapter adapter adapter adapter adapter adapter adapter pouch USA JPN Korea Australia Brazil PRC CND Mexico Argentina 110-127 V 100 V 220 V 240 V 115 - 220 V 220 V 110-127 V 110-127 V 240 V
Service code Beige/Brown Beige/Green 4822 219 10058 4822 219 10059 4822 219 10167 4822 219 10174 4822 219 10277 4822 219 10338 4822 219 10069 4822 219 10455 4822 600 10663 4822 736 17009 4822 736 17011 4822 736 17012 4822 219 10621 4822 219 10622 4822 219 10623 4822 219 10624 4822 219 10625 4822 219 10626 4822 219 10627 4822 219 10628 4822 219 10686 4822 600 10866 4822 736 17009 4822 736 17011 4822 736 17012
13
Directions for use F, D, UK, NL, I Directions for use E, P, TR, Gr Directions for use DK, S, N, SF
Parts with numbers from 100 and higher cannot be ordered separately
DISASSEMBLY ADVICE + POSSIBLE COMPLAINTS DISASSEMBLY ADVICE To open the product N.B. CAP 103 will be damaged, when it is removed. For this reason, 2 spare caps are supplied free when you order items 1 and 4 - 9. Remove CAP 103 ( see picture ) Remove DECORATIVE RING 10 Remove SCREW 2 3x N.B. To avoid dust from getting into the pump, the suction opening has been closed with a rubber cap. Remove the rubber cap before assembling. After the product has been repaired, it should function properly and has to meet the safety requirements as laid down and officially established at this moment. Test Criteria and Controls Voltage Total product Adapter: primary voltage secondary voltage N.B. In the underpart the screws are guided by rubber bearings H. ( see cross section ) After ± 10 turns with the screw driver, the screws must be pushed out with the help of a hex key, due to friction between the screws and the rubber bearings ( see picture ) Pump Motor rollers 13.0 V Ampere 380 mA ± 10 %
220-240 V 13.0 V 400 mA If < 12.5 V adapter is defective 13.0 V 13.0 V 180 mA ± 10 % 180 mA ± 10 %
Pull open the product ( see picture )
N.B. The opening between Roller 1 and the suction area must be smaller than 0.1 mm. In case the opening is larger, power unit 4 must be replaced. ( see picture )
Possible complaints. Status 1. Switch in ' OFF" position 2. Switch set to Level 1 Failure Pump functions Pump doesn't function Possible Complaint ON/OFF switch defective Adapter defective ON/OFF switch defective Internal wiring broken defective P.C.B. Motor Pump defective Filter is clogged Electronic switch C defective defective P.C.B. Electronic switch C defective Defective P.C.B. Sleeves got loose Defective vacuum stop buttons Gearing motor defective Pump clogged - filter missing Internal wiring broken
3. Switch set to level 1 - 5 and product not placed on the skin 4. Switch set to Level 1- 5 and product properly placed
Product functions
Product doesn't function
To check if the product functions properly , set the switch to level 1 and cover the suction opening with your thumb. see fig 2 cleaning rollers.
PCS 101 216