Text preview for : TFC-04056_CTC211_System_Control_Component_Level_Troubleshooting.pdf part of RCA D52130 Large File 6 pare RAR Folder containing: Flow Charts, Tech Tips, Trouble Shooting Manuals, Updates, Module Training, and Symptom Fixes



Back to : RCA_CTC210-211_01.rar | Home

THOMSON TECHNICAL COMMUNICATION
Television

Troubleshooting Flow Chart

TFC-04056

The information contained herein is provided solely to assist qualified Technician in the diagnosis of the problem described. It is not intended as a modification or alteration of the product.
REVISION DATE: Chassis: CTC211 9/23/2004

TOPIC: System Control Component Level Troubleshooting SYMPTOM: Dead Set - Pulsing

Press power button, green LED is lit & main board standby power supply is operational 1 1A

Is there 5 vdc at pin 51 of U13101

NO

Check reset circuit Q13107 and Q13106

YES 2A Check pins 40 & 42 for 5 vpp osc. 8 mhz Suspect Y13101, C13106, C13107

2

NO

YES 3A Check pin 5 for 5.2 VDC NO Suspect Power fail circuit Q14607 & Q14608

3

YES

go to page 2

Product Safety Information
Product Safety information is contained in the appropriate Thomson Service Data covering models/chassis referenced herein. All specified Product Safety requirements and testing shall be complied with prior to returning equipment to the customer. Servicers who defeat safety features or fail to perform safety checks may be liable for any resulting damages and may expose themselves and others to possible injury.
First Edition First Printing Copyright 2003 Thomson multimedia Inc. Printed in U.S.A. Trademark(s) ® Registered Marca(s) Registrada(s)

Page 1 of 2

THOMSON INC.

CTC211 System Control Component Troubleshooting

4A Is there 5 vpp and 5vdc at pins 43 & 44 of U13101 NO Remove U13102 eeprom

4B YES Is there 2.5 vdc at pins 43 and 44 of U13101 NO Suspect U13101

4C

Check U13203 pins 1,12,5,14 for clock & data

YES

NO

5A

YES

Suspect U13203

System control is Operational

Product Safety Information
Product Safety information is contained in the appropriate Thomson Service Data covering models/chassis referenced herein. All specified Product Safety requirements and testing shall be complied with prior to returning equipment to the customer. Servicers who defeat safety features or fail to perform safety checks may be liable for any resulting damages and may expose themselves and others to possible injury.
First Edition First Printing Copyright 2003 Thomson multimedia Inc. Printed in U.S.A. Trademark(s) ® Registered Marca(s) Registrada(s)

Page 2 of 2

THOMSON INC.