DISASSEMBLY PROCEDURE
A Assembly 1 1-1 Meter Panel Remove the screws marked [210], [220] and [230]. The Meter Panel can then be removed. (Fig. 1) The type and quantity of the screws marked [210] and [220] are: [210]: 24CH:10, 32CH:11, 40CH:13, 48CH:14, 56CH:15 [220]: 24CH:7, 32CH:8, 40CH:9, 48CH:10, 56CH:11 2 2-1 2-2 MONO Assembly Remove the meter panel (See Procedure 1.) Remove the screws marked [160] and [180]. (Fig. 1) Lift the fader side of the control panel and then remove the MONO Assembly by pulling it forward. [160]: 40CH:21, 56CH:31 [180]: 24CH:26, 32CH:31, 40CH:26, 48CH:52, 56CH:26

Rear view

(Bottom)

[210]

(Top)
[220]

[110]

Side view
[230]

Top view

(REAR)

[180]

[120]

[160]

(FRONT)
[120]: Bind Head Tapping Screw-B 3.0X8 FMZN2BL (EP600190) [160]: Bind Head Tapping Screw-B 3.0X8 FMZN2BL (EP600190) [180]: Bind Head Tapping Screw-B 3.0X8 FMZN2BL (EP600190) [210]: Bind Head Tapping Screw-B 4.0X8 FMZN2BL (EG340190) [220]: Bind Head Screw 4.0X8 FMZN2BL (EG340360) [230]: Bind Head Screw 4.0X25 MFZN2BL

Fig.1

18

M2500

3 3-1 3-2

MASTER Assembly Remove the meter panel. (See Procedure 1.) Remove the twenty [20] screws marked [120]. Lift the fader side of the control panel, remove the connectors and then remove the MASTER Assembly by pulling it forward. (Fig. 1)

B Circuit Board 1 1-1 1-2 1-3 MONO Assembly Remove the meter panel. (See Procedure A1.) Remove the MONO assembly. (See Procedure A2.) Remove the following circuit boards by removing the screws indicated for each of them. (Fig. 2)

Circuit Board & Unit IN1 IN2 IN3 IN4

Ref No. 40 70 130 150

PARTS NAME Hexagon Socket Tapping Screw-P 3X25 MFZNBL Hexagon Socket Tapping Screw-P 3X25 MFZNBL Bind Head Tapping Screw-B 3.0X8 MFZN2BL PCB Support CS-0305 KSS

PARTS No. V3289800 V3289800 EP600190 EP600230

Q'ty 11 9 8 4

[40]

[40]

IN1

IN2 [70] [70]

[180]

[180] INPAN

[120]

[120]

IN3

[130]

[130] IN4

Fig.2

19

M2500

2 2-1 2-2 2-3

MASTER Assembly Remove the meter panel. (See Procedure A1.) Remove the MASTER assembly. (See Procedure A3.) Remove the following circuit boards according to the listed order by removing the screws indicated for each of them. (Fig3)

Circuit Board & Unit ST1 ST2 ST3

Ref No. 60 90 150 140

PARTS NAME Hexagon Socket Tapping Screw-P 3X25 MFZNBL Hexagon Socket Tapping Screw-P 3X25 MFZNBL Hexagon Socket Tapping Screw-P 3X25 MFZNBL Bind Head Tapping Screw-B 3.0X8 MFZN2BL PCB Support CBS-6K

PARTS No. V3289800 V3289800 V3289800 EP600190

Q'ty 8 6 2 4 4

ST4

170

Circuit Board & Unit MAS1 MAS2 1/2

Ref No. 220 280 270

PARTS NAME Hexagon Socket Tapping Screw-P 3X25 MFZNBL Hexagon Socket Tapping Screw-P 3X25 MFZNBL Bind Head Tapping Screw-B 3.0X8 MFZN2BL Bonding Tapping Screw-B 3.0X8 MFZN2BL Hexagon Socket Tapping Screw-P 3X25 MFZNBL Bind Head Tapping Screw-B 3.0X8 MFZN2BL Nut

PARTS No. V3289800 V3289800 EP600190 VN413300 V3289800 EP600190

Q'ty 12 8 6 2 5 10

MAS2 2/2 MAS3 1/2

290 350 340

MAS3 2/2 MASPAN 1/2 MASPAN 2/2 400 400

Bind Head Tapping Screw-B 3.0X8 MFZN2BL Bind Head Tapping Screw-B 3.0X8 MFZN2BL

EP600190 EP600190

2 2

Circuit Board & Unit CTRL 1/5~4/5 CTRL 5/5
*1 OVERALL ASSEMBLY

Ref No. 470 110*1

PARTS NAME Bind Head Tapping Screw-B 3.0X8 MFZN2BL Bonding Tapping Screw-B 3.0X8 MFZN2BL

PARTS No. EP600190 VN413300

Q'ty 12 2

20

M2500

[220]
CTRL 5/5

[60]

ST1

MAS1

[280] [90] [270] [290] [280] [400]

[470]
CTRL 4/5 ST2 CTRL 3/5 MAS2 1/2 MAS2 2/2 MASPAN 2/2 MASPAN 1/2

[470]

[470] [150] [140] [350]
CTRL 1/5 MAS3 1/2 ST3

[470]
MAS4 CTRL 2/5 ST4

[140]

[340]

MAS3 2/2

Fig.3

Battery VN103500
VN103600(Battery holder for VN103500)

· Notice for back-up battery removal Push the battery as shows in figure, then the battery will pop up. · Druk de batterij naar beneden zoals aangeven in de tekening, de batterij springt dan naar voren.
Note that the battery is installed on the CTRL circuit board but it is not a component part.

21

M2500

3 3-1 3-2 3-3

3-4

3-5

MASOUT 1, 2, 3 Remove the meter panel. (See Procedure A1.) Remove the MASTER assembly. (See Procedure A3.) Remove the twelve (12) screws marked [30] from the rear panel. The MASOUT 1 circuit board can then be removed. (Fig. 4) Remove the forty-eight (48) screws marked [50] from the rear panel. The MASOUT 2 circuit board can then be removed. (Fig. 4) Remove the twelve (12) screws marked [70] from the rear panel. The MASOUT 3 circuit board can then be removed. (Fig. 4) ISRT 1/6 ~ 6/6 Remove the meter panel. (See Procedure A1.) Remove the MASTER assembly. (See Procedure A3.) Remove the MONO assembly. (See Procedure A2.) Remove the following circuit boards according to the listed order by removing the screws indicated for each of them.

4 4-1 4-2 4-3

Circuit Board & Unit ISRT 1/6 ISRT 2/6

Ref No. 380 420 440 390

PARTS NAME PCB Support CBS-6K GIN LIAN Bind Head Screw 4.0X8 MFZN2BL Bind Head Screw 4.0X8 MFZN2BL Bind Head Tapping Screw-B 3.0X8 MFZN2BL Bind Head Screw 4.0X8 MFZN2BL Bind Head Screw 4.0X8 MFZN2BL Bind Head Screw 4.0X8 MFZN2BL Bind Head Screw 4.0X8 MFZN2BL Bind Head Screw 4.0X8 MFZN2BL

PARTS No. VZ336600 EG340360 EG340360 EP600190 EG340360 EG340360 EG340360 EG340360 EG340360

Q'ty 4 4 4 8 4 4 4 4 1

ISRT 3/6

440 390

ISRT 4/6 ISRT 5/6 ISRT 6/6

390 390 390

22

M2500

[50]

[30]

[70]

[110]

MASOUT2 MASOUT1 MASOUT3 CTRL 5/5

[30]: Bonding Tapping Screw-B 3.0X8 MFZN2BL (VN413300) [50]: Bonding Tapping Screw-B 3.0X8 MFZN2BL (VN413300) [70]: Bonding Tapping Screw-B 3.0X8 MFZN2BL (VN413300)

Fig.4

Earth Bar(LARGE) Bus Earth Bar
INST 2/6 [390] [420] [440] [380] [390] [440] INST 3/6

ISRT 1/6

ISRT 6/6

[390]

INST 4/6

[390]

[390]

INST 5/6

Fig.5

23

M2500

5 5-1 5-2 5-3

INJK Remove the meter panel. (See Procedure A1.) Remove the MONO assembly. (See Procedure A2.) Remove the screws marked [460] and the hexagonalnuts marked [A] from the rear panel. The INJK can then be removed. (Fig. 6)

6 6-1 6-2 6-3

STJK Remove the meter panel. (See Procedure A1.) Remove the MASTER assembly. (See Procedure A3.) Remove the two (2) screws marked [480] and the six (6) hexagonal nuts marked [B] from the rear panel. The STJK can then be removed. (Fig. 6)

7 7-1 7-2 7-3 7-4 7-5

Meter 1 and Meter 2 Remove the meter panel. (See Procedure A1.) Remove the four (4) screws marked [80]. The Meters can then be removed. (Fig. 7) Remove the Meter 1 1/3 to 3/3 circuit boards by removing the seven (7) screws marked [70]. (Fig. 7) Remove the Meter 2 1/2 circuit board by removing the seven (7) screws marked [70]. (Fig. 7) Remove the Meter 2 2/2 circuit board by removing the five (5) screws marked [70]. (Fig. 7)

INJK

STJK

INJK

[460]

[480]

[460]

INJK

STJK

INJK

[460]: Bonding Tapping Screw-B 3.0X8 MFZN2BL (VN413300) [480]: Bonding Tapping Screw-B 3.0X8 MFZN2BL (VN413300)

Fig.6

24

M2500

METER1 3/3

[70]

METER1 2/3

METER2 1/2 3/3 [70]

METER2 1/2 2/3

[70]

METER1 1/3

[70]

METER2 1/2 1/3

METER2 2/2 2/3

[70]

METER2 2/2 1/3

[80]

[80]

[80]

[80]

[70]: Bind Head Tapping Screw-B 3.0X8 MFZN2BL (EP600190)