Text preview for : servtool.pdf part of Nokia 7110 Nokia 7110 Service Manual



Back to : 7110.rar | Home

PAMS Technical Documentation NSE­5 Series Transceivers

Service Tools

Issue 1 07/99

NSE­5 Service Tools

PAMS Technical Documentation

CONTENTS Page No
Battery Adapter BDC­3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Battery BBD­3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Jig MJS­8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Test Probe MPA­1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flash Loading Adapter FLA­5 (Sales Pack) . . . . . . . . . . . . . . . . . . . . . . Flash Prommer FPS­4S (Sales Pack) . . . . . . . . . . . . . . . . . . . . . . . . . . . Security Box TDF­4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Audio Box JBA­4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Cable SCH­5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warranty Cable SCH­6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Cable ADS­1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D15­D15 Cable AXS­5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Cable PCC­1B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Cable SCB­3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External Antenna Cable XRC­1B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MBUS Cable DAU­9S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MBUS Cable DAU­9P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Cable PCS­1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modular T­adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SW Security Device PKD­1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dongle/Flash Device FLS­1 (Sales Pack) . . . . . . . . . . . . . . . . . . . . . . . . 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Page 2

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

Battery Adapter BDC­3
The Battery Adapter BDC­3 is used along with an external battery capacity meter to check battery capacity. Note that Li­ion batteries have an internal protection circuit to prevent deep discharge. Product Code Battery Adapter BDC­3: View of BDC­3 0770083

Issue 1 07/99

Page 3

NSE­5 Service Tools

PAMS Technical Documentation

Service Battery BBD­3
The Service Battery BBD­3 is used in place of the phone's normal battery during service, to supply a controlled operating voltage to the phone for current and charger calibration, and is also required when flashing the phone. Note that the cable SCB­3 (0730114) is also required for charger calibration. Product Code Service Battery BBD­3: View of BBD­3 0775071

Page 4

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

Module Jig MJS­8
The Module Jig MJS­8 is used for component level repair of the system/RF module. * Product Code Module Jig MJS­8: View of MJS­8 0775170

*) Connect the External antenna cable XRC­1B, service Cable SCH­5, and the DC Cable PCS­1 to the MJS­8 jig. The service cable SCH­5 can be replaced by the DAU­9P cable. Note: The nominal supply voltage for MJS­8 is +4.1 V. The supply voltage must not exceed +6.0 V.

Issue 1 07/99

Page 5

NSE­5 Service Tools

PAMS Technical Documentation

Audio Test Probe MPA­1
MPA­1 is a Audio Test Probe used for testing the microphone signal together with the Module Jig MJS­8. Product Code Audio Test Probe MPA­1: View of MPA­1 0775169

MPA­1 Audio Test Probe

MJS­8 Module Jig

Page 6

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

Flash Loading Adapter FLA­5 (Sales Pack)
The Flash Loading Adapter FLA­5 is used with the Service Battery BBD­3 and Service Cable SCH­5. Power is supplied to FLA­5 from the Flash Security Box TDF­4 via the DC cable PCC­1B, (The PCC­1B cable can be replaced with a Travel Charger ACH­6), and is connected to the Flash Prommer FPS­4S with the cable AXS­5. The sales pack includes: ­ Flash Loader Adapter FLA­5 ­ Service cable SCH­5 ­ D15 ­ D15 Cable AXS­5 ­ Installation software for FPS­4 Product Code Flash Loading Adapter FLA­5: View of FLA­5 0080178 0770085 0730098 0730091 8400041

Issue 1 07/99

Page 7

NSE­5 Service Tools

PAMS Technical Documentation

Flash Prommer FPS­4S (Sales Pack)
The Flash Prommer FPS­4S is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU software only needs to be loaded to the prommer once. The sales pack includes: ­ Charger ACL­3E ­ Printer Cable ­ D9 ­ D9 Cable AXS­4 ­ Installation software for FPS­4 Product Code Flash Prommer FPS­4S: View of FPS­4S 0080178 0680015 0730029 0730090 8400041

Page 8

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

Security Box TDF­4
The Security Box TDF­4 is required for updating MCU software, and infra red testing. Note1: TDF­4 is delivered in de­activated mode. Fill in the enclosed Activation Request Form, and fax to NMP Salo to get the activation code The infra red module JLP­1 is not included in the TDF­4 sales package

Note2: Product Code

Security Box TDF­4: View of TDF­4

0770106

Issue 1 07/99

Page 9

NSE­5 Service Tools

PAMS Technical Documentation

Service Audio Box JBA­4
The Service Audio Box JBA­4 is used between the Service Cable SCH­5, MBUS Cable DAU­9S, and Audio Cable ADS­1. Product Code Service Audio Box JBA­4: View of JBA­4 0770094

Page 10

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

Service Cable SCH­5
The Service Cable SCH­5 is used between the phone and Service Audio Box JBA­4 (or modular T­adapter. It is also used between the phone and the Flash Loading Adapter FLA­5. Product Code Service Cable SCH­5: View of SCH­5 0730098

Issue 1 07/99

Page 11

NSE­5 Service Tools

PAMS Technical Documentation

Warranty Cable SCH­6
The Warranty cable SCH­6 is used to connect two phones, and enables transfer of data (stored numbers etc.) from one phone to another. Product Code Warranty Cable SCH­6: View of SCH­6 0730099

Page 12

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

Audio Cable ADS­1
Audio cable is an adapter routing AF signals (MIC/EAR) from 8 pin modular connector to two BNC connectors. It is used to connect JBA­4, SCH­5, and DAU­9S. Product code Audio Cable ADS­1: View of ADS­1 0730011

Issue 1 07/99

Page 13

NSE­5 Service Tools

PAMS Technical Documentation

D15­D15 Cable AXS­5
The D15­D15 Cable AXS­5 is used to connect two 15 pin D connectors. e.g. between FLA­5 and FPS­4S. Product Code D15­D15 Cable AXS­5: View of AXS­5 0730091

Page 14

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

DC Cable PCC­1B
The DC Cable PCC­1B is used e.g. to connect FLA­5 and TDF­4. Product Code DC Cable PCC­1B: View of PCC­1 0770053

Issue 1 07/99

Page 15

NSE­5 Service Tools

PAMS Technical Documentation

DC Cable SCB­3
The DC Cable SCB­3 is used to connect the Service Battery to the charger connection Vin of the phone when doing the charger calibration service procedure. Product Code DC Cable SCB­3: View of SCB­3 0730114

Page 16

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

External Antenna Cable XRC­1B
The External Antenna Cable is used to connect the transceiver to measuring equipment during servicing. Note: Product Code External Antenna Cable XRC­1B: View of XRC­1B 0730128 Typical attenuation at 900 MHz is 0.7 dB. Typical attenuation at 1800 MHz is 0.9 dB.

Issue 1 07/99

Page 17

NSE­5 Service Tools

PAMS Technical Documentation

MBUS Cable DAU­9S
The MBUS Cable DAU­9S has a modular connector, and is used with the service Audio Box JBA­4, or a modular T­adapter. Product Code MBUS Cable DAU­9S: View of DAU­9S 0730108

Page 18

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

MBUS Cable DAU­9P
The MBUS Cable DAU­9P has a phone system connector, and is used between the phone and external devices. Product Code MBUS Cable DAU­9P: View of DAU­9P 0730109

Issue 1 07/99

Page 19

NSE­5 Service Tools

PAMS Technical Documentation

Power Cable PCS­1
The Power Cable PCS­1 is used to connect the module jigs JBT­1 and JBS­19 to an external power supply. Product Code Power Cable PCS­1: View of PCS­1 0730012

Page 20

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

Modular T­adapter
The modular T­adapter is a suitable branching unit to provide the needed parallel modular connections. Product Code Modular T­adapter: View of Modular T­adapter 4626134

Issue 1 07/99

Page 21

NSE­5 Service Tools

PAMS Technical Documentation

SW Security Device PKD­1
SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Whitout the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.

Caution: Make sure thet you have switched off the PC and the printer before making connections! Caution: Do not connected the PKD­1 to the serial port. You may damage your PKD­1!
Product Code SW Security Device PKD­1: View of SW Security Device 0750018

Page 22

Issue 1 07/99

PAMS Technical Documentation

NSE­5 Service Tools

Dongle/Flash Device FLS­1 (Sales Pack)
FLS­1 is a dongle and flash device incorporated into one package, developed specifically for POS use. Product Code Sales Pack ­APAC Sales Pack ­ Europe/Africa View of FLS­1 0081290 0081291

Sales Pack Contents

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á
Part No. 0750130 0730163 0770177 0770176 0774120 0774123 0275405 Description FLS­1 Flash Device. AXS­4U Cable. Disk­ Installation package,16bit Dongle Drivers. Disk ­ Installation package, 32bit Dongle Drivers. Disk ­ Installation package for the FLE­5 Drivers. Disk ­ Remote Update Application Installation Package. Installation and User Guide 0275404 Registration Request Form

Note: in addition to this Sales Pack, a Service Cable will be required to connect the FLS­1 to the Product/Phone to be flashed, e.g. SCH­5, and a software package to run the flashing process.

The picture overleaf shows how to connect the FLS­1 device and associated cables to the PC and Product/Phone.

Issue 1 07/99

Page 23

NSE­5 Service Tools FLS­1 Connection Diagram

PAMS Technical Documentation

1. FLS­1 (connects to
parallel port)

4

2

SCH­5

3 AXS­4U 4 PC 1

3

2

Page 24

Issue 1 07/99