Text preview for : r561.pdf part of Tektronix r561 Tektronix r561.pdf



Back to : r561.pdf | Home

TM 9-6625-963-14-1


TECHNICAL MANUAL




OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT, AND
GENERAL SUPPORT MAINTENANCE MANUAL
(INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

GRAPHICAL DISPLAY SYSTEM,
TEKTRONIX TYPE 561 SERIES


This copy is a reprint which includes current
pages from Change 1.




HEADQUARTERS, DEPARTMENT OF THE ARMY
OCTOBER 1972
NOTE

This manual is an authentication of the manufacture's commercial literature which, through
usage, has been found to cover the data required to operate and maintain this equipment.
Since the manual was not prepared in accordance in with military specifications, the format
has not been structured to considered level of maintenance nor to include a formal section
on depot overhaul standards.

This manual contains copyrighted information. Reproduced by permission of Tektronix,
Incorporated. All rights reserved.
CHANGE TM 9-6625-963-14-1
Change 2
No. 2 HEADQUARTERS
DEPARTMENT OF THE ARMY
WASHINGTON, DC, 12 August 1986


OPERATOR'S ORGANIZATIONAL, DIRECT SUPPORT AND

GENERAL SUPPORT MAINTENANCE MANUAL,

INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST:

GRAPHICAL DISPLAY SYSTEM

TEKTRONIX TYPE 561 SERIES (NSN 4931-0(1-910-8164)

Current as of 16 April 1986


TM 9-6625-963-14-1, 11 October 1972, is changed as follows:

1. Remove old pages and insert new pages as indicated below. New or changed material is indicated by a vertical bar in the margin
of the page.

Remove pages Insert pages

0 -1 and 0 -2 0 -1 and 0 -2
12 - 1 through 12 - 11 12 - 1 through 12 - 16

2. File this change sheet in front of the publication for reference purposes.



By Order of the Secretary of the Army:

JOHN A. WICKHAM, JR.
General, United States Army
Chief of Staff
Official:

R. L. DILWORTH
Brigadier General, United States Army
The Adjutant General


Distribution:
To be distributed in accordance with DA Form 12-34C, Block No. 319, requirements for calibration procedures publications.
TM 9-6625-963-14-1
CHANGE 1



}
CHANGE HEADQUARTERS
DEPARTMENT OF THE ARMY
NO. 1 WASHINGTON, D.C. 20 MARCH 1975


OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT,

AND SUPPORT MAINTENANCE MANUAL,

INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST:

GRAPHICAL DISPLAY SYSTEM, TEKTRONIX

TYPE 561 SERIES (NSN 4931-00-910-8164)

Current as of 11 September 1974

TM 9-6625-963-14-1, 11 October 1972, is changed as follows:
1. The title is changed to read as shown above.
2. Remove old pages and insert new pages as indicated below. New or changed material is indicated by a vertical bar in the margin
of the page.

Remove pages Insert pages

i and ii i and ii
12-1 through 12-11

3. File this change sheet in front of the publication for reference purposes.
TM 9-6625-963-14-1

TECHNICAL MANUAL

NO. 9-6625-963-14-1 } HEADQUARTERS
DEPARTMENT OF THE ARMY
Washington, D.C. 11 October 1972



OPERATOR'S ORGANIZATIONAL, DIRECT SUPPORT, AND
GENERAL SUPPORT MAINTENANCE MANUAL

INCLUDING REPAIR PARTS SPECIAL TOOL LIST
GRAPHICAL DISPLAY SYSTEM,

TEKTRONIX TYPE 561 SERIES

(NSN 4931-00-910-8164)



Page
SECTION 0 INTRODUCTION................................................................................................................................................0-1
1 CHARACTERISTICS RM561A...........................................................................................................................1-1
1A TYPE R561B SPECIFICATION ...................................................................................................................... 1-1A
2 OPERATING INSTRUCTIONS RM561A............................................................................................................2-1
2A OPERATING INSTRUCTIONS R561B ........................................................................................................... 2-1A
3 CIRCUIT DESCRIPTION RM561A ....................................................................................................................3-1
3A CIRCUIT DESCRIPTION R561B. ................................................................................................................... 3-1A
4 MAINTENANCE RM561A ..................................................................................................................................4-1
4A MAINTENANCE R561B .................................................................................................................................. 4-1A
5 PERFORMANCE CHECK RM561A...................................................................................................................5-1
5A PERFORMANCE CHECK VIRGULE MAINTENANCE CALIBRATION R561B............................................... 5-1A
6 MAINTENANCE CALIBRATION RM561A..........................................................................................................6-1
PARTS LIST ABBREVIATIONS......................................................................................................................7-0.1
7 ELECTRICAL, PARTS LIST...............................................................................................................................7-1
8 MECHANICAL, PARTS LIST .............................................................................................................................8-1
9 DIAGRAMS ........................................................................................................................................................9-1
10 PREVENTIVE MAINTENANCE INSTRUCTIONS............................................................................................10-1
11 RACKMOUNTING............................................................................................................................................11-1
12 REPAIR PARTS LIST ......................................................................................................................................12-1
Appendix A REFERENCES.................................................................................................................................................. A-1
B BASIC ISSUE ITEMS LIST AND ITEMS TROOP INSTALLED OR AUTHORIZED LIST.................................. B-1
C MAINTENANCE ALLOCATION CHART ........................................................................................................... C-1


Change 1 i
TM 9-6625-963-14-1




Figure 1-1A. Type RM561A Oscilloscope

ii
TM 9-6625-963-14-1

SECTION 0

INTRODUCTION


Scope Report of Packaging and Handling Deficiencies (DD Form
The manual includes installation and operation 6). Fill out and forward DD Form 6 as prescribed in AR 700-8
instructions and covers organizational, direct support (DS), (Army), NAVSUP Pub 378 (Navy), AFR 71-41 (Air Force), and
and general support (GS) maintenance. It describes Graphical MCO P4030.29 (Marine Corps).
Display System, Tektronix Type 561 Series. The basic issue
items list appears in appendix B. Appendix 'B is current as of Discrepancy in Shipment Report. Fill out and forward
1 September 1972. Discrepancy in Shipment Report (SF 361) as prescribed in AR
55-38 (Army), NAV SUPINST 4610.33 (Navy), AFM 7-18 (Air
Indexes of Publications Force), and MCO P4610.19A (Marine Corps).
DA Pam 310-4. Refer to the latest issue of DA Pam 310-4
to determine if there are any new editions, changes, or Reporting of Equipment Publication Improvements. The
additional publications pertaining to the equipment. reporting of errors, omissions, and recommendations for
improving this publication by the individual user is encouraged.
DA Pam 310-7. Refer to DA Pam 310-7 to determine Reports should be submitted on DA Form 2028
whether there are Modification Work Orders (MWO) pertaining (Recommended Changes to Publications) and forwarded
to the equipment. direct to: Commander, U. S. Army TMDE Support Group,
ATTN: AMXTM-LML, Redstone Arsenal, AL 35898-5400.
Forms and Records
Reports of Maintenance and Unsatisfactory Equipment.
Use equipment forms and records in accordance with
instructions given in TM 38750.

Change 2 0-1
Fig. 1-1. Type R561B Oscilloscope.

0-2
SECTION 1

CHARACTERISTICS RM561A

General Information Output voltage - 1 millivolt to 100 volts, peak-to-peak, in 6
The Tektronix Type RM561A Oscilloscope is essentially steps. The 1 v position provides an output of 0.1 volt into 50
an indicator unit with provision for two plug-in units. The plug- ohms.
in unit in the right-hand opening controls the horizontal (X-axis) Accuracy - Peak-to-peak amplitude within 3% of indicated
deflection, and the plug-in unit in the left-hand opening voltage.
controls the vertical (Y-axis) deflection. The plug-in units con Rise-time - Typically 5 microseconds.
be selected from any of the Tektronix '2' Series or '3' Series
groups to provide the desired oscilloscope performance. Power Supplies
Electronically regulated for stable operation with normal line
Cathode-Ray Tube voltage variations and widely varying loads. The low voltage
Type - T5032-31-1 (rectangular ceramic-envelope). supplies hold regulation within