File information: | |
File name: | 212_Maintenance_Manual.pdf [preview 212 Maintenance Manual] |
Size: | 1071 kB |
Extension: | |
Mfg: | Tektronix |
Model: | 212 Maintenance Manual 🔎 |
Original: | 212 Maintenance Manual 🔎 |
Descr: | Tektronix 212_Maintenance_Manual.pdf |
Group: | Electronics > Other |
Uploaded: | 21-12-2019 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 212_Maintenance_Manual.pdf TM 9-6625-646-14&P TECHNICAL MANUAL OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS) FOR OSCILLOSCOPE, TEKTRONIX, MODEL 212 NSN 6625-01-061-5519 MULTIPLE LAUNCH ROCKET SYSTEM DEPARTMENT OF THE ARMY JUNE 1984 TM 9-6625-646-14&P WARNING DANGEROUS VOLTAGE is used in the operation of this equipment DEATH ON CONTACT may result if personnel fail to observe safety precautions Never work on electronic equipment unless there is another person nearby who is familiar with the operation and hazards of the equipment and who is competent in administering first aid. When the technician is aided by operators, he must warn them about dangerous areas. Whenever possible, the power supply to the equipment must be shut off before beginning work on the equipment. Take particular care to ground every capacitor likely to hold a dangerous potential. When working inside the equipment, after the power has been turned off, always ground every part before touching it. Be careful not to contact high-voltage connections when installing or operating this equipment. Whenever the nature of the operation permits, keep one hand away from the equipment to reduce the hazard of current flowing through vital organs of the body. WARNING Do not be misled by the term "low voltage." Potentials as low as 50 volts may cause death under adverse conditions. COMMON and probe ground straps are electrically connected. Therefore, an elevated reference applied to any is present on each - as indicated by the yellow warning bands under the probe retractable hook tips. For Artificial Respiration, refer to FM 21-11. EXTREMELY DANGEROUS POTENTIALS greater than 500 volts exist in the following units: 1. CRT Power Supply 2. Horizontal Deflection System 3. Vertical Deflection System a/(b blank) TM 9-6625-646-14&P Copyright 1972 by Tektronix, Inc. All rights reserved. REPRODUCED BY PERMISSION OF TEKTRONIX, INC. Distribution is limited to use in connection with the Multiple Launch Rocket System. Technical Manual HEADQUARTERS |
Date | User | Rating | Comment |