File information: | |
File name: | 5991-4258EN W4630A Series DDR4 BGA Interposers for Logic Analyzers - Data Sheet c20140820 [9].pdf [preview 5991-4258EN W4630A Series DDR4 BGA Interposers for Logic Analyzers - Data Sheet c20140820 [9]] |
Size: | 4249 kB |
Extension: | |
Mfg: | Agilent |
Model: | 5991-4258EN W4630A Series DDR4 BGA Interposers for Logic Analyzers - Data Sheet c20140820 [9] 🔎 |
Original: | 5991-4258EN W4630A Series DDR4 BGA Interposers for Logic Analyzers - Data Sheet c20140820 [9] 🔎 |
Descr: | Agilent 5991-4258EN W4630A Series DDR4 BGA Interposers for Logic Analyzers - Data Sheet c20140820 [9].pdf |
Group: | Electronics > Other |
Uploaded: | 24-10-2021 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 5991-4258EN W4630A Series DDR4 BGA Interposers for Logic Analyzers - Data Sheet c20140820 [9].pdf Keysight W4630A Series DDR4 BGA Interposers for Logic Analyzers Data Sheet 02 | Keysight | W4630A Series DDR4 BGA Interposers for Logic Analyzers - Data Sheet The W4630A series DDR4 BGA interposers enable probing of embedded memory DRAM directly at the ball grid array with Keysight Technologies, Inc. logic analyzers. The Keysight W4630A series DDR4 BGA interposers for logic analyzers enable viewing of data traffic on industry standard DDR4 DRAMs with the Keysight U4154A logic analysis systems. The DDR4 BGA Interposer Advantage Features Benefits Connects directly to the DDR4 BGA balls. Eliminates reflections from mid-bus probing methods. Also eliminates design time, prototype builds, and trace routing required to design in alternative probing methods. Supports: Get complete signal access to the DDR4 signals critical to your - Single die x4, x8 configuration debug and validation effort. - Stacked/quad-die x4, x8 configuration - Operating transfer rate of 2400 Mb/s (validated) Operate at full speed making measurements with a - Designed to achieve higher data rates once DDR4 DRAM Keysight U4154B or U4154A logic analyzer. technology achieves higher data rates (to be validated) - Using U4154A with APS (Advanced Probe Settings*) enables highest data rates Supports either leaded or lead-free solder. Easily works with all solder finishes. Designed to tolerate lead-free soldering temperature profiles. Contract manufactures available for those without Eliminates the need to develop BGA soldering expertise. the in-house expertise or facilities for soldering BGAs. Flexible "wings" with ZIF connectors. Ensures reliable connection to the ZIF probes. Enables placement of the probe cables around adjacent components. Minimizes the torque to the balls of the BGA. Attach to E5849A single-ended ZIF probes for connection to the Optimizes the use of logic analyzer channels by allowing logic analyzer. assignment of channels to 4, 8 or 16 bits on each DRAM. * To enable Advanced Probe Settings refer to Tech brief # 5991-0799EN. Maximum transfer rates are subject to variables i |
Date | User | Rating | Comment |