Goldstar | CIT2162X | Low brightness. | C820 ( 10uF ) | 14-09-04 |
Goldstar | CIT2162X PC08X8 | Dark - only get pic when A1 at max | 180v to vid stage high at 278v; C401 10µ 160v on 112v rail o/c | 14-09-04 |
Goldstar | CIT2168 | Dead | LOPTx shorted turns | 14-09-04 |
Goldstar | CIT2168 | Dead - 118v HT low at 50v | C806S 47µ 160v HT smoothing cap | 14-09-04 |
Goldstar | CIT2168 | Field collapse - int | Pin 5 TDA1170N was 5v instead of 25v. D301 1N4003 faulty. If chip turns out to be faulty use genuine Goldstar chip (others won't work - allegedly) Also check R320 10R 1w | 14-09-04 |
Goldstar | CIT2168 | Int start up | D401 1N4003 o/c in line dr supply | 14-09-04 |
Goldstar | CIT2168 | No start up | Check R811P 22k 3w, D805P R10J in start up cct, C805P 100µ 16v | 14-09-04 |
Goldstar | CIT2168 | Sound muted & goes to Stby after 10mins. | Replace the TDA1940 IC401 remove the link J8 & fit 1k instead. | 14-09-04 |
Goldstar | CIT2168 | Txt absent | Dry joints conn P102 on txt pcb | 14-09-04 |
Goldstar | CIT2168F | Field foldover | C423, C302 100µ 35v | 14-09-04 |
|
Goldstar | CIT2168F CIT2190F etc | No sound - pic ok - sw to st/by aft 10 mins | Pin 7 IC401 TDA1940 produces muting o/p - chip u/s. Fit 1k res in place of J8 link | 14-09-04 |
Goldstar | CIT2170 | Fails to power up from StBy | D/J on main relay : remove retin & replace | 14-09-04 |
Goldstar | CIT2170F | No start up or int sw off | Check for dry joints on main relay | 14-09-04 |
Goldstar | CIT2170F | Patterning from cold | C827 1000µ 25v leaky | 14-09-04 |
Goldstar | CIT2170F | Patterning horiz lines on pic | C827 1000µ 25v - tested ok on esr meter | 14-09-04 |
Goldstar | CIT2172 | Cannot store contrast setting (Too low) | Normal - change R520 to 18k | 14-09-04 |
Goldstar | CIT2172X | No Text after replacing TDA3651. | Must only use TDA as supplied By Goldstar | 14-09-04 |
Goldstar | CIT2172X | Remains in search mode | R80 1M5 high res | 14-09-04 |
Goldstar | CIT2172X CIT2175X | Low contrast at sw on & can't be stored | Replace R520 with 18k | 14-09-04 |
Goldstar | CIT2172X CIT2175X | No sound when playing pre recs | Adj L204 quarter turn clockwise | 14-09-04 |
Goldstar | CIT2175 PC07X2 | Field collapse | Field dr signal incorrect from IC201 TDA4502A - chip faulty | 14-09-04 |
Goldstar | CIT2175X | Frame - height & linearity poor. | C202 ( 0.22uf ) connected to pin 2 of TDA4502. | 14-09-04 |
Goldstar | CIT2175X | Int dead with motorboating sound | Check all elects in psu - remove glue first by freezing | 14-09-04 |
Goldstar | CIT2175X | Int loss of sound & pic | L202 - green coil labelled 2K2 was int o/c | 14-09-04 |
Goldstar | CIT2175X | Linearity poor/lach of height | C202 0µ22 in field osc cct | 14-09-04 |
Goldstar | CIT2175X | Poor height / lin | C202 0.22µ connected to pin 2 TDA4502 | 14-09-04 |
Goldstar | CIT2175X | Slow start up | C811 47µ 25v also check C812 100µ 16v, C808 1µ 50v & C813 100µ 16v | 14-09-04 |
Goldstar | CIT2176 | Dead - fuse blown | R806 270k o/c, IC801 TDA4601 s/c, Q802 2SD1911 s/c, R801 4R7 5w o/c | 14-09-04 |
Goldstar | CIT2176 | Trips then into st/by | C710 4µ7 250v | 14-09-04 |
Goldstar | CIT2180 | Frame collapse. | IC301 & R320 | 14-09-04 |