datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:APC DP300BC

APC DP300BC free download

UPS - Uninterruptable Power Supply repair information and schematics

File information:
File name:JA01GB02.PDF
Size:137 kB
Extension:pdf
Mfg:APC
Model:DP300BC 🔎
Original:
Descr:User Manual APC DP300BC
Group:Electronics > Computer equipment > UPS
Uploaded:18-02-2008
User:Zurilab
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name JA01GB02.PDF

USER GUIDE 310BC - 330BC CONTENTS Introduction Stop - Start Programming parameters Reading out measurements Alarms - what to do The events logger Preventive maintenance Economy mode Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section 8 7JA0001GB rev 02 Page 1 of 6 1.0 INTRODUCTION 1.1 General Congratulations on your choice of UPS (Uninterruptible Power Supply). This UPS has been designed and produced for reliable and troublefree long-term use as the major parameters. For you it means that once installed and commissioned, you can forget it. You only have to arrange a preventive maintenance as described in section 7 of this manual. For the user, who wants to get more familiar with the UPS - not needed for the daily use - the following information is useful. 1.2 The display unit The display unit - placed on the front of the UPS - is the link between user and UPS. It consists of a display, an alarm LED, and a keyboard. The display is used for showing parameters, measured values, and alarm messages. The alarm LED is together with an acoustic signal the indicator for unusual operating situations. The keyboard is used for programming of operating parameters and for calling read outs of parameters / alarm messages. 2.0 STOP - START 2.1 General According to electrical regulations only the local authorized electrical installer is normally allowed to perform a complete switching in and out of the UPS, as it involves operation of the battery supply breaker, where touch of high voltage parts is possible. For above reasons the normal user can only switch the UPS into stand-by mode and from here back into normal operation. Stop Open the front door and activate the red "OFF" push-button Alarm LED lights. Acoustic alarm sounds for 10 seconds. 2.2 display shows * Stand-by * WARNING: Please read maintenance section, if UPS has to be stopped for more than one week. 2.3 Start Open the front door and activate the green "ON" push-button display shows Normal operation Load power xx% 7JA0001GB rev 02 Page 2 of 6 3.0 PROGRAMMING PARAMETERS 3.1 General Some operating parameters can be programmed directly from the keyboard, but this has already been done during the commissioning. Unless you are not quite sure of the consequence of changing the following parameters, then let it be a task for your local dealer, if needed. Parameters Std. factory setting English OFF OFF Comments Language of text in display Automatic restart by mains return if the battery has been discharged due to a long mains failure ON will switch the system into by-pass mode NOTE: The system must not run in bypass mode for longer periods of time as the batteries will not be recharged ON results in 8 hours continous boost charge Aut. boost charge for 8 hours after battery operation Special use Check of back-up time by 100% discharging* Check of battery condition by 25% discharging* Pressing key after selecting this parameter reset the battery monitor alarms and flush

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
APC DP300C - APC DP300C - APC DP300E - APC DP300BC - APC DP3000 - APC DP300E - APC DP100 Series -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Samsung BN44-00259A BN44-00260A BN44-00261A BN44-00262A BN44-00289B BN44-00291 No power to backlight repair

script execution: 0.02 s