Sanyo | CBP2180-00 | Int pic | Dry joints C554 22µ 250v | 14-09-04 |
Sanyo | CBP2180A | Field collapse | L451 o/c | 14-09-04 |
Sanyo | CBP2180A | No pic & Txt too far to right - sound ok | Hor pos preset (VR404?) - upright, rear left of pcb | 14-09-04 |
Sanyo | CBP2180A | St/by only | Dry joint R512 | 14-09-04 |
Sanyo | CBP2180A A5 | Field - various effects often int | Check L451 33mH for o/c | 14-09-04 |
Sanyo | CBP2180A A5 | Field non lin, crooked verts & int col | 12v supply risen to 14v as IC552 12v reg had dry joint to chassis | 14-09-04 |
Sanyo | CBP2180A A5 | Pic shift to left & Q422 on DPC pcb overheats | Replace line shift pot VR411 50k - cleaning will usually result in call back | 14-09-04 |
Sanyo | CBP2558 E3 | It start up &/or shut down - LEDs stayed on | IC380 12v reg 3122V int o/p & faulty | 14-09-04 |
Sanyo | CBP2565 | Dead - LED alight | Q724 2SA608 in psu s/c | 14-09-04 |
Sanyo | CBP2565 E3 | Dim pic with flaring - HT low | Thick film sensing unit faulty - unavailable but a replacement can be made on vero board - source TV Mag | 14-09-04 |
|
Sanyo | CBP2572 ED1 | BLANK RASTER NO SOUND NO ON SCREEN DISPLAYS . MEMO | REPLACE OR TRY RE-PROGGRAMMING BY PRESSING THE SERVICE SWITCH AND VOLUME PLUS BUTTON TOGETHER . SERVICE SWITCH BEHIND SMALL H | 14-09-04 |
Sanyo | CBP2572 ED1 | Blank raster, no sound or OSD | 2 x NVM chips on sigs panel sus; can be replaced or reprog | 14-09-04 |
Sanyo | CBP2572 ED1 | Dark & lacking contrast | Unable to get "OK" indication when adj A1 volts in service mode. IC501 VCU2136 on digital pcb faulty - pt no 409 212 0608 | 14-09-04 |
Sanyo | CBP2572 ED1 | Dead | R301 3R9 15w surge res o/c, Q303 2SC4429 chopper tr s/c, R315 dry joints caused it-also IC301 TEA2260 faulty | 14-09-04 |
Sanyo | CBP2572 ED1 | EW faulty | DPU2553/75 deflection proc chip | 14-09-04 |
Sanyo | CBP2572 ED1 | Int loss off air signals | Q173 D/J | 14-09-04 |
Sanyo | CBP2572 ED1 | Q903 s/c R301 ( 3R9 ) o/c | Check R3165 D/J and TEA2260 | 14-09-04 |
Sanyo | CBP2572 ED1 | STRANGE E/W FAULT | CHECK DPU2553/75 ON DIGI BOARD | 14-09-04 |
Sanyo | CBP2572 ED1 | To reprog NVM memory chips | Press service button (thro' hole in set front) & VOL+ together - be careful - all previous data will be lost! | 14-09-04 |
Sanyo | CBP2572 ED1 | WHITE DOT PATTERN | DTI2223-06 , ON DIGITAL PCB | 14-09-04 |
Sanyo | CBP2576 | Excess width & pin cush dist | L750 & C653 | 14-09-04 |
Sanyo | CBP2576 | JUST SNOW IN TUNING MODE | CHECK FOR CORRECT CONFIGERATION NUMBER 02014 TO ENTER SERVICE MODE PRESS MEMORY ON CT AND WITHIN 5 SECS PRESS MENU BUTTON ON REMOTE THEN ENTER THE ABOVE NUMBER | 14-09-04 |
Sanyo | CBP2576 | NO SOUND | REPLACE ICP853 AND IC1680 | 14-09-04 |
Sanyo | CBP2576 | Pin cush dist | Replace C750 2.2mfd | 14-09-04 |
SANYO | CBP2576 | VERY BRIGHT RASTER SOUND OK | CHECK R534 22K OHM | 14-09-04 |
Sanyo | CBP2576 ED0 | Burning smell then dead | Burn up on pcb at line scan connector K-FF | 14-09-04 |
Sanyo | CBP2576 ED0 | Dead - whistle only - LOPTr 2SD1556 leaky | ,Overheats when replaced with int narrow pic, replaced C750 47µ 50v & C705 2µ2 50v for hi esr & check for dry joints in LOP section | 14-09-04 |
Sanyo | CBP2576 ED0 | No E-W correction | ICP R756 (N20) o/c | 14-09-04 |
Sanyo | CBP2576 ED0 | No sound | Carry out "start NVM" proc as described in manual | 14-09-04 |
Sanyo | CBP2576A | Field top foldover & excess height | C703 100µ 50v | 14-09-04 |